PRODUCT SHEET
°CControl
LCD
230 VAC
24VDC [Power Distributor]
Display
Ventilator
Communication
Interface
Vehicle Battery
[Vehicle Accu]
System Battery
[System Accu]
Product: SV 07
Segment : Defense
Division: Security Communication
SV 07 enableS mobile communication
The Ascom Supply Unit SV 07 enables the
uninterruptable and emission free supply of
communication equipment in vehicles, remote
stations and containers.
The Supply Unit SV 07 provides electrical power for communication
equipment with 24VDC nominal voltage. It is optimized for operation of
sensitive radio receivers and gets supplied by different sources such as AC
mains, generator or vehicle power. An additional system battery covers peak
demands and supplies uninterrupted power. Internal control circuits protect
the equipment. An integrated display informs the local user of relevant data
such as source voltage or load current. The Supply Unit SV 07 offers five
different protected connections and allows for parallel operation in order
to increase the available power.
The Supply Unit SV 07
Block diagram and wiring of the SV 07.

PRODUCT SHEET: SV 07
2
conStruction
User and connection elements of the Ascom Supply Unit SV 07
Position Label Explanation
1 230 V Connector for 230VAC power input
2 O On/Off switch for 230VAC
3 Acousti c alarm
4 Display an d three keys for menu operation
5 Power Dis tributor 1..5 Over-cur rent circuit breaker 30A
6 Communication Inter face Multi functional conne ctor (reserved f or future use)
7 Power Distributor 1..5 Conne ctor for 24VDC power out
8 Ground screw
9 System Accu Connector for 24VDC power input from system batter y
10 Vehicle Accu Connector for 24VDC power input from vehicle power

PRODUCT SHEET: SV 07
3
FunctionS
The Ascom Supply Unit SV 07 supports the following modes of operation:
Mobile Operation
If the vehicle motor is running the loads are fed from the vehicle alternator
via the SV 07. At the same time the system battery is charged via the SV 07. If
the vehicle motor is not running, the flow of energy is inverted: vehicle battery
and system battery supply the SV 07 and the connected loads. The protection
circuit of the SV 07 avoids a total discharge of the vehicle battery.
Stationary Operation
The SV 07 is supplied by a 230VAC source such as AC mains or a generator
and – if existing – is supported by the system battery. The system battery is
charged and the other loads are fed via SV 07.
Charging of Vehicle Battery
If the vehicle battery is connected to 9 [System Accu] the vehicle
battery is charged. Charging current is automatically limited to 20A max.
Housing, Cooling, Ventilation
The Supply Unit SV 07 is available in a 19’’ housing. It is intended for use in
a wheeled vehicle. The housing is made of aluminium and complies with IP55.
Internal cooling is realised using a passive cooling system. If required, ex-
ternal ventilation of the cooling element can be achieved through an optional
external fan. Operation of the external fan is controlled by SV 07.
Cables connected to SV 07 do not require shielding.

PRODUCT SHEET: SV 07
Technical Specific ation
4
Mechanical Data
Size (WxHx D)/mm 470x220x270
Weight approx. 17kg
Supply
In 230VAC 230VAC/50Hz +10/-15%, max. 8A
In “Vehicle Accu” (vehicle power)
Switching point vehicle power
Tripping point vehicl e power
In “System Accu”
Out “Power Distributor”
Max. output power
24 - 33VDC, 20A max.
Remark: fuse / switch provided at source side
>24VDC or
>23VDC selectable
<22VDC or
<21VDC select able
80A max.
Remark: fuse / switch provided at source side
5x24VDC nominal , 30A max. per line, over-
load protected
at input „230 V“: 1kW
at input“Vehicle Accu”: 300W
at combined inpu t
“System Accu” and „230 V“: ca 3.2kW
at combined inpu t
“Vehicle Accu” and “Sys tem Accu”:
ca. 2.5 kW
Protection
Overload and reve rse-polarity
In “Vehicle Accu”
electronic pr otection against overload and
reverse-polarit y
20A, protection provided by vehicle
battery
In “System Accu” 80A, protection provided by syste m battery
Out 5 identical lines protected by 30A each
Isolation
230V - side: 1.5kV
24V - side: 100V
Residual current p rotec tion protection provide d by supply side
Charge p ower
at input „230 V“: < 11A
Outpu t charge current at
“System Accu”
at input “Vehicle Accu”: < 45A
when connecting the vehicle bat tery to
„System Ac cu“ (operational mode
’Loading of Vehicle Batteries’): < 20A
Managem ent Features
Managem ent Protocol SNMP V3 on request
Environment
Operational temperature -2 0..+5 0°C
Storage tempera ture -30 ..+60 °C
Humidity Guideline 201.1 method I (95 % rF)
Shock Guideline 302.1, 5.3 (15g half sinus)
Vibration
Guideline 301.1, method I, modified
MIL-STD-810E, 514.4, Fig. 514.4-1, -2, -3
EMC
IEC 61000-3-2 : 2004
Emission
MIL-STD-461E:
CE102, 10 kHz-10 MHz
RE102, 2 MHz-1 GHz
IEC 61000-6-2:2005
IEC 61000-4-2:2000
IEC 61000-4-3:2002
Immunity
IEC 61000-4-4:2004
IEC 61000-4-5:2001
IEC 61000-4-6:2004
IEC 61000-4-8:2001
IEC 61000-4-11:2004
Security
EN 60950-1 (2006)
Ordering Infor mation
SV 07 193302-21000
Option: external fan (alternative
to option metal cover sheet)
193302-21208
Option: metal cover shee t
(alternative to option external
193302-21209
fan)
Although the information in this publication is represented in good faith and believed to be correct, Ascom makes no representations or warranties
as to the completeness or accuracy of the information. In no event will be Ascom responsible for damages of any nature whatsover resulting from the
use of or reliance upon the information contained in this document. Such information is subjec t to change without notice. Ascom gives no warranty
and makes no representation that any of its products contained in this document are designed for any particular use or purpose. The graphics and
contents of this document are the copyrighted work of Ascom and contain proprietar y trademarks and tradenames of Ascom.
Ascom (Switzerland) Ltd. Ascom (Finland) Oy Ascom Poland SP. z.o.o. Ascom (CZ) s.r.o.
Belpstrasse 37 Pakkalankuja 6 Ul. Farbiarska 71a Zemské právo 1199/5
CH-3000 Bern 14 FI-01510 Vantaa PL-02-862 Warsaw CZ-10200 Praha 10
T + 41 31 999 13 65 T + 358 9 825 901 T +48 22 544 22 00 T + 420 267 219 512
F + 41 31 999 16 82 F + 358 9 825 902 79 F + 48 22 544 22 05 F + 420 267 219 511
securitycommunication@ascom.com info@ascom.fi ascom@ascom.com.pl info@ascom.cz
www.ascom.com/defense www.ascom.fi www.ascom.com.pl www.ascom.cz
01.2010 © Ascom (Switzerland) Ltd.