Asber ARF-23 Owner’s Manual

REFRIGERATORS AND FREEZERS
Manual for installation, use, and maintenance
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page2
Contents
1 RECEIVING AND INSPECTING THE EQUIPMENT .................................................................................... 3
2 SPECIFICATIONS .................................................................................................................................... 4
3 DIMENSIONS ......................................................................................................................................... 6
4 INSTALLATION ..................................................................................................................................... 10
4.1 UNCRATING ..................................................................................................................................... 10
4.2 LOCATION ........................................................................................................................................ 10
4.3 DATA PLATE ..................................................................................................................................... 11
4.4 INSTALLATION OF CASTORS OR OPTIONAL LEGS ............................................................................ 11
4.5 LEVELING ......................................................................................................................................... 12
4.6 ELECTRICAL CONNECTIONS ............................................................................................................. 13
4.7 SHELVING INSTALLATION ................................................................................................................ 14
5 OPERATION ......................................................................................................................................... 14
5.1 ANALOG THERMOSTAT ................................................................................................................... 14
5.2 ELECTRONIC CONTROL .................................................................................................................... 15
5.3 OTHER FUNCTIONS ......................................................................................................................... 17
6 MAINTENANCE .................................................................................................................................... 18
6.1 CLEANING THE CONDENSER COIL ................................................................................................... 20
6.2 GASKET ............................................................................................................................................ 21
6.3 DOORS/HINGES ............................................................................................................................... 21
6.4 DRAIN .............................................................................................................................................. 22
7 WIRING DIAGRAMS ............................................................................................................................. 23
8 TROUBLE SHOOTING ........................................................................................................................... 31
Limited Warranty ...................................................................................................................................... 32
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page3
1 RECEIVING AND INSPECTING THE EQUIPMENT
Up on receiving your new Asber Refrigerator, check the package and the machine for any damages that may have occurred during transportation. Visually inspect the exterior of the package. I f damaged, open and inspect the contents with the carrier. Any damage should be noted and reported on the delivering carriers receipt. In the event that the exterior is not damaged, yet up on opening, there is concealed damage to the equipment notify, the carrier immediately. Notification should be made verbally as well as in written form. Request an inspection by the shipping company of the damaged equipment. Retain all crating material until inspection has been made. Contact the dealer through which you purchased the unit.
Check the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
A NOTE FROM OUR QUALITY CONTROL MANAGER
CONGRATULATIONS ON YOUR NEW PURCHASE. WE WOULD LIKE TO WELCOME YOU TO THE ASBER TEAM. THE UNIT IN FRONT OF YOU IS A GREAT PIECE OF EQUIPMENT THAT WILL BECOME ONE OF YOUR MOST RELAIBLE TOOLS IN YOUR DAILY OPERATIONS FOR YEARS TO COME! PRIOR TO SHIPPING YOUR UNIT, OUR TRAINED SERVICE TECHNICIANS TESTED YOUR UNIT FOR A PERIOD OF 12 HOURS. THIS PERFORMANCE TEST WAS RECORDED AND A COPY OF THE RESULTS IS INCLUDED WITH THIS SERVICE MANUAL. DURING THIS TEST, OUR HIGHLY QUALIFIED PERSONNEL INSPECTED YOUR MACHINE FOR LEAKS, LOSE COMPONENTS, AND IMPROPER NOISE LEVELS. WE ALSO TESTED THE COOLING PERFORMANCE IN AN EFFORT TO GIVE YOU THE BEST AND MOST RELAIBLE UNIT POSSIBLE.
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page4
REACH IN, REFRIGERATORS AND FREEZERS, GENERAL SPECS
Model
Capac.
(Cu.Ft.)
#of
Shvls
BTU'S
/Hr
Temperature Operation
Pressure in
Suction Line*
Super-
Heat**
Ref.
Amount
Ref.
Type
Ship
Weight
SetPoint
Cut in
ARR-17
17 3 1666 0°
C/32°F
5°C/41°F
10-16PSIG
7°C/13°F
9.8 oz
R-134a
295
ARR-23
23 3 1666 0°
C/32°F
5°C/41°F
10-16PSIG
7°C/13°F
11.3oz
R-134a
295
ARR-49
49 6 2104 0°
C/32°F
5°C/41°F
10-16PSIG
7°C/13°F
13.4 oz
R-134a
475
ARF-17
17 3 2493
-22°C/-8°F
-18°C/0°F
12-16PSIG
4°C/7°F
16.6oz
R-404A
475
ARF-23
23 3 2493
-22°C/-8°F
-18°C/0°F
14-18PSIG
4°C/7°F
16.6 oz
R-404A
295
ARF-49
49 6 3644
-22°C/-8°F
-18°C/0°F
14-18PSIG
4°C/7°F
23.9oz
R-404A
475
ARR-17-1G
17 3 1666 0°
C/32°F
5°C/41°F
10-16PSIG
7°C/13°F
9.8 oz
R-134a
295
ARR-23-1G
23 3 1666 0°
C/32°F
5°C/41°F
10-16PSIG
7°C/13°F
12.3oz
R-134a
295
ARR-49-2G
49 6 2104 0°
C/32°F
5°C/41°F
10-16PSIG
7°C/13°F
17.2oz
R-134a
475
2 SPECIFICATIONS
Note: * The pressure in the suction line is recommended at 32°C / 90°F maximum of ambient temperature. **Superheat measured in the outlet of the evaporator at 32°C / 90°F
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page5
REACH IN REFRIGERATORS AND FREEZERS, ELECTRICAL SPECS
Models
HP Voltage
Amp.
Max.
NEMA
Plug
Breaker
Size*
Wire gauge recommended for 2% voltage drop in supply
circuits **
40 ft ***
60 ft
80 ft
100 ft
120 ft
140 ft
ARR-17
1/4
115 220
5.8
3.2
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10 AWG 12 AWG
ARF-17
3/4
115 220
8.8
4.5
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10 AWG 12 AWG
ARR-17-1G
1/4
115 220
5.8
3.2
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10 AWG 12 AWG
ARR-23
1/4
115 220
5.6
3.1
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10 AWG 12 AWG
ARR-23-1G
1/4
115 220
6.0
3.4
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10 AWG 14 AWG
10 AWG 12 AWG
ARR-49
1/3 3/8
115
6.9
3.5
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10AWG
14 AWG
10 AWG 14 AWG
10 AWG 12 AWG
ARR-49-2G
1/3 3/8
115 220
6.9
3.9
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
12 AWG 14 AWG
12 AWG 14 AWG
10 AWG 14 AWG
10 AWG 12 AWG
8 AWG
12 AWG
ARF-23
3/4
115 220
8.5
4.5
5-15P
2P+TT
15 amp 10 amp
14 AWG 14 AWG
12 AWG 14 AWG
10 AWG 14 AWG
10 AWG 12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
ARF-23-1G
3/4
115
8.6
5-15P
15 amp
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
ARF-49
1
115 220
12.9
6.5
5-15P
2P+TT
20 amp 10 amp
12 AWG 14 AWG
10 AWG 12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
8 AWG
12 AWG
6 AWG
12 AWG
Note:
*Breaker sizes are recommended to protect the equipment by overload; this breaker only must be dedicated for the equipment. ** If the equipment is installed faraway of the circuit breaker, these are the wire gauge recommend to connect the appliance; if the distance is higher that the chart values, please contact an electrician. ***Distance in feet from the breaker or the power supply to the appliance.
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page6
3 DIMENSIONS
ARR/ARF - 23
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page7
ARR/ARF – 49
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page8
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page9
REACH-INS SERVICE MANUAL/Rev. JUN. 2015
Page10
4 INSTALLATION
4.1 UNCRATING
Remove the outer packaging. Cut the 4 clamps that hold the refrigerator to the skid. Lift the unit off the skid.
If machine was laid down during this operation, remember to leave the cabinet up right for 24 hours before connecting to power source.
4.2 LOCATION
Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weigh to the unit and its contents. For the most efficient operation, be sure to provide at least three (3) inches between sides, back and top of the unit.
THE MACHINES NEEDS TO BE INSTALLED 2 FEET AWAY FROM ANY HEAT SOURCES.
The unit should not be installed under ambient temperatures higher than 100 °F. If the relative humidity is higher than 60 %, the door frames may sweat water. This is not a malfunctioning of the unit.
WARNING The following actions will void your warranty:
-Modification of power cord.
-Connecting the unit to any extension cord.
-Neglecting to install the castors or optional legs.
Inside cabinet:
The first cleaning must happen when you unpack the unit and before it is turned ON. For this, you have to clean the unit with warm water and mild detergent. When it is cleaned and dry, proceed to install accessories and plug your unit in to a dedicated outlet. WAIT 24 HOURS
BEFORE PLACING PRODUCT IN THE UNIT. This will guarantee that it is working properly. Consequential damages are not covered under warranty.
Outside cabinet:
Be sure that the unit has access to ample air to breathe. Avoid hot corners and locations near stoves and ovens. It is recommended the unit be installed no closer than 3” from any wall. The place where the refrigerator is placed must be open and clean. This will reduce the amount of debris and dirt on the condenser fan and coil.