Artesyn NLP150L User Manual

The NLP150L series of 150 Watt ac-dc open-frame power supplies are available with single, triple or quad outputs. The quad output versions described in this datasheet are housed in a 3.8 x 7.8 x
1.26 inch package. All NLP150L series power supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support current sharing. The power supplies are designed for use in 1U shelves or boxes, and are primarily intended for networking applications that have a heavy logic content, such as access concentrators, midrange routers, LAN switches and shared media hubs.
Embedded Power for Business-Critical Continuity
NLP150L Series
Quad output
Special Features
• 90 VAC to 264 VAC universal input range
• Provides low voltage outputs (3.3 V)
• EN61000-3-2 compliant
• Overvoltage and short circuit protection
• Power fail detection
• Current sharing (on VA and VB)
• 3.8 x 7.8 x 1.26 inches
• UL, CSA and VDE safety approvals and CE-marked to LVD
• Compliance to EN55022-B conducted noise standard
• Compliance to EN55022-A radiated noise standard
• Meets all applicable and relevant immunity standards EN61000-4-2, -3, -4, -5 and -6
• Available RoHS compliant
• 2 year warranty
Total Power: 110-150W Input Voltage: 90 - 264VAC # of Outputs: Quad
Safety
VDE 0805/EN60950/IEC950 File No. 10401-3336-0162/47587 Licence No. 123897
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Rev.02.20.07
NLP150L Series
1 of 5
Rev.02.20.07
NLP150L Series
2 of 5
Embedded Power for Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Specifications
EMC CHARACTERISTICS (continued)
(10)
Surge EN61000-4-5 Level 3 Fast transients EN61000-4-4 Level 3 Radiated immunity EN61000-4-3 Level 3 Conducted immunity EN61000-4-6 Level 3
GENERAL SPECIFICATIONS
Hold-up time 120 Vac @ 60 Hz 20 ms @ 150 W
Efficiency 120 Vac @ 150 W 73% typical
Isolation voltage Input/output 3000 Vac
Input/chassis 1500 Vac
Approvals and EN60950, VDE0805, IEC950 standards pending UL1950, CSA C22.2 No. 950
Weight 540 g (19 oz)
MTBF (@ 25°C) MIL-HDBK-217F 350,000 hours min.
Bellcore 800,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
(8)
Thermal performance Operating ambient, 0 °C to +50 °C
(See derating curve) Non-operating -40 °C to +85 °C 50 °C to 70 °C ambient, Derate to
convection cooled 50% load 0 °C to 50 °C ambient, 110 W
convection cooled 0 °C to 50 °C ambient, 150 W
300 LFM forced air Peak (0 °C to +50 °C)
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 6) 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV
OUTPUT SPECIFICATIONS
Total regulation Main output ±2.0% (Line and load) Auxiliary outputs ±5.0%
Rise time At turn-on 1.5 s, max.
Transient response Main output 5.0% or 250 mV
75% to 100% max. dev., 1 ms max. step at 0.1 A/μs recovery to 1%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main outputs 125%, ±10%
Short circuit protection Cyclic operation Continuous
Minimum output current Single and multiple See table
INPUT SPECIFICATIONS
Input voltage range Universal input 90-264 Vac
Input frequency range 47-63 Hz
Input surge current 264 Vac (cold start) 40 A max.
Safety ground 264 Vac, 60Hz 0.99 mA leakage current
Input current 120 Vac @ 150 W 1.95 A rms
230 Vac @ 150 W 1.10 A rms
Input fuse UL/IEC127 F3.15A H, 250 Vac
EMC CHARACTERISTICS
(10)
Conducted emissions EN55022, FCC part 15 Level B Radiated emissions EN55022, FCC part 15 Level A
Harmonic current EN61000-3-2 Compliant emission correction
ESD air EN61000-4-2 Level 3 ESD contact EN61000-4-2 Level 3