Arrow Hart - Cooper Wiring Devices Weather Protective Devices Catalog

Industrial Specification Grade Receptacle Covers N-1, N-2
Weather Protective Devices N-3
Power-Lock® Receptacles and Flanged Inlets with Weather Protective Lift Lids N-4
50 Amp Flanged Inlets with Weather Protective Lift Lids N-5
Weather Protective In-Use Deep Receptacle Covers N-6
Plastic Weather Protective Covers N-7
Metal Weather Protective Covers N-8
Cast Aluminum Boxes N-9
Weather Protective Covers with Devices N-10
Weather Protective Boots N-12
Weather Protective Devices
Rain, snow, ice, moisture, humidity, dust – Cooper Wiring Devices has the products you need to meet virtually any environmental challenge with protected electrical service. Our broad line of weather protective devices features rugged, attractively designed units manufactured from impact-resistant, UV-resistant, and corrosion-resistant metals and plastic materials.
All our weather protective devices are designed for high­level performance in such common outdoor applications as pool areas, decks, garages, seasonal lighting, low voltage landscape lighting and wet work areas. We also offer lockable devices for schools, hospitals, offices, workshops, vending machines, unsecured public areas, or any other location where use must be restricted or secured against tampering.
N
N-Intro
-
1
WEATHER PROTECTIVE DEVICES
INDUSTRIAL COMMERCIAL RESIDENTIAL
Weather Protective Devices
National Electric Code Compliance
Cooper Wiring Devices offers a broad range of weather protective wiring devices for almost every application. These distinctively designed, rugged products provide complete protection against rain, snow, ice, moisture, humidity and dust. They are manufactured in both metals and plastic materials that are impact-resistant, UV-resistant, and corrosion-resistant.
Cooper’s weather protective products are ideal for applications that include building exteriors, plant wash down areas and wet locations, loading docks, decks, pool areas, garages, construction sites, seasonal lighting, and low voltage landscape lighting. Lockable devices are available for applications that must be secure from tampering or where use must be restricted, such as schools, hospitals, offices, workshops, vending machines, and unsecured public areas.
A receptacle installed outdoors in a location protected from the weather or in other damp locations shall have an enclosure for the receptacle that is weatherproof when the receptacle is covered (attachment plug cap not inserted and receptacle covers closed).
An installation suitable for wet locations shall also be considered suitable for damp locations.
A receptacle shall be considered to be in a location protected from the weather where located under roofed open porches, canopies, marquees, and the like, and will not be subjected to a beating rain or water run-off.
NEC 406.8 Receptacles in Damp or Wet Locations
Weather Protective Boots For 15, 20 & 30 Amp
Nylon Safety Grip
TM
and AutoGrip
TM
Plugs & Connectors
Damp Locations
15- and 20-Ampere Outdoor Receptacles.
15- and 20-Ampere, 125- and 250-volt receptacles installed outdoors in a wet location shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted.
Wet Locations
Technical Information For Weather Protective Boots
Cooper Wiring Devices weather protective boots protect wiring devices from moisture, acids, dust, oil, metal chips or other contaminants that can create shock hazards or electrical shorts. They also minimize the possibility of nuisance tripping on sensitive ground fault protected circuits. In addition, they provide protection from mechanical shock for devices used in high abuse applications. Boots meet the IP 55 rating requirements per IEC 521 standard.
All of Cooper’s weather protective devices are UL Listed (except where noted). Many are also CSA-certified or available as CSA-certified. Please consult our Customer Service for availability.
N-Intro
-
2
WEATHER PROTECTIVE DEVICES
INDUSTRIAL COMMERCIAL RESIDENTIAL
Features and Benefits
WeatherBoxTM– In-Use Cover
Wet Location Cover
Flexible hinge for abrupt usage resists breakage.
Rugged polycarbonate design resists abuse and temperature extremes. UV-resistant, non-corrosive, non-conductive.
Self-closing tinted transparent cover permits status check of plug.
Extended base with built­in strain relief plus cord ports 2” (50.8mm) from wall, allowing cords exit naturally. Also holds cord in place during opening and closing.
Gasket seals out moisture for electrical safety.
Rugged polycarbonate design resists abuse and temperature extremes. UV-resistant, non-corrosive, non-conductive.
Self-closing covers allow use in wet locations.
Stainless steel mounting screw.
Factory-attached gasket to cover minimizes labor for installer.
Extended hinge 2.75” (69.85mm) from box allows cover to be completely opened on flat surface without interference from wall.
Sloped design sheds water, ice, snow, seals out moisture.
Two exit ports accept up to 12/3 cords.
Lockable by padlock.
N-1
WEATHER PROTECTIVE DEVICES
TESTING & CODE COMPLIANCE
• UL listed to UL514A (file no. E92122) except WLRD1, WLRS1, WLRS2 (file no. E15022).
• CSA Certified to C22.2 no. 18. WLRD1, WLRS1, WLRS2: (file no. LR222); others: cUL Certified. (file no. E92122), except as noted.
MATERIAL CHARACTERISTICS
Die cast aluminum Temperature Rating:
-40º C to 105º C.
INDUSTRIAL COMMERCIAL RESIDENTIAL
Industrial Specification Grade Receptacle Covers
EPDM gasketing material on WLRD1 and
WLRS1 provide excellent resistance to ozone,weathering and temperatures from
-46º C to 127ºC ( -50ºF to 260ºF).
FEATURES
UL Listed for wet locations (cover closed)
and damp locations (cover open or closed).
Self closing spring door assures full protection.
Die cast copper free aluminum with epoxy
finish provides maximum corrosion resistance.
Deluxe Wet Location Covers for FS/FD Boxes
Die Cast Aluminum Covers for Duplex and Single Receptacles
Description Catalog No.
Duplex receptacle cover, horizontal mounting. WLRD1
Single receptacle cover, vertical mounting, 1.38" (34.9mm) face diameter. WLRS1 Use with straight blade 15 and 20 amp and 15 amp Hart-Lock™ receptacles.
Single receptacle cover, vertical mounting, 1.56" (39.7mm) face diameter. WLRS2 Use with 20 and 30 amp Hart-Lock™ receptacles.
Adapter, flush mounts above covers to standard boxes. WLRA1*
* Not UL or CSA listed.
R
C
Gasketing material provides excellent
resistance to weather.
Duplex covers used with any duplex
receptacle.
FEATURES
UL Listed for wet locations (cover closed)
and damp locations (cover open or closed).
Self closing spring door assures full protection.
Standard Wet Location Covers for FS/FD Boxes
Die Cast Aluminum Covers for Duplex and Single Receptacles
Description Catalog No.
Duplex receptacle, vertical mounting. 7879FS
Duplex receptacle, vertical mounting, yellow corrosion resistant. 7879FSCR
Single receptacle cover, vertical mounting, 1.38-1.56" (34.9-39.7mm) 7420 face diameter. Used with 15 and 20 amp single straight blade receptacles and 15, 20 and 30 amp single locking receptacles.
Single receptacle cover, vertical mounting, 1.38-1.56" (34.9-39.7mm) 7420CR face diameter, yellow corrosion resistant finish.
Used with 15 and 20 amp single straight blade receptacles and 15, 20 and 30 amp single locking receptacles
Single receptacle, vertical mounting for 2.12" (53.8mm) face diameter. 7420A
Used with 30 amp straight blade receptacles
Adapter, flush mounts above covers to standard boxes. 7349*
Note: Cat. No. 7420, 7420CR have inserts for protecting toggle and tap action switches. Can be used with most standard length toggle switches. * Not UL or CSA listed.
WLRD-1
3.30"Dia. (83.8mm)
1.20"
(30.5mm)
3.25"
(82.6mm)
4.56"
(115.8mm)
1.88"
(47.8mm)
2.85"
(72.5mm)
3.25" (82.6mm)
1.88"
(47.8mm)
2.91"
(73.9mm)
4.44"
(112.8mm)
1.13"
(28.7mm)
WLRS-1
7349
7420CR
4.44"
(112.8mm)
1.13"
(28.7mm)
2.91" (73.9mm)
2.81"
(71.4mm)
4.48" (113.8mm)
7788CR
5740NS
23007
7420
3.30"Dia. (83.8mm)
1.20"
(30.5mm)
4.56" (115.8mm)
1.88"
(47.8mm)
2.85"
(72.5mm)
3.25" (82.6mm)
20416N
N-2
WEATHER PROTECTIVE DEVICES
INDUSTRIAL COMMERCIAL RESIDENTIAL
TESTING & CODE COMPLIANCE
• Listed to UL 514A for metal covers (file no. E92122) or UL 514C for plastic covers (file no. E2458).
• cUL listed to CSA C22.2 no.18 (same file nos. as above) except as noted.
MATERIAL CHARACTERISTICS
Environmental: Flammability per UL 94 requirements; 7788CR, 7788, 7777 are V2 rated. Temperature Rating:
-40ºC to 105ºC, except 7777:
-40°C to 80°C.
Industrial Specification Grade Receptacle Covers
Gasketing material provides excellent
resistance to weather.
FEATURES
UL Listed for wet locations (cover closed)
and damp locations (cover open or closed).
Self closing spring door assures full protection.
Wet Location Covers and Flush Boxes for 30, 50 and 60 Amp Straight Blade Receptacles
Die Cast Aluminum and Polycarbonate Boxes and Covers
Description Catalog No.
Weather protective cast aluminum surface box with 5740NS* lift lid cover, 1.25" (31.8mm) pipe thread opening.
Weather protective lift lid cover for 4.69" (22.0mm) flush box. 5741NS* Use box 2.125" (53.96mm) deep or larger.
Weather protective lift lid cover for FS/FD boxes. Use box 2.125" (53.96mm) deep or larger. 7420C
Gray polycarbonate weatherproof lift lid cover for two gang boxes. 7777 Fits 2 gang FS/FD boxes with 3.25" (82.6mm) x 3.75" (95.25mm) mounting holes
* Not UL or CSA listed.
Self closing spring door assures full
protection.
Gasketing material provides excellent
resistance to weather.
FEATURES
Designed for FS/FD boxes.
UL Listed for wet locations (cover closed) damp
locations (cover open or closed).
Wet Location Covers for 50 Amp Locking Receptacles
Die Cast Aluminum and Glass Filled Nylon Covers
Description Catalog No.
Die cast aluminum lift lid cover. 7770
Yellow glass filled nylon lift lid cover. 7788CR
Gray glass filled nylon lift lid cover. 7788
Self closing spring door assures full
protection.
Gasketing material provides excellent
resistance to weather.
FEATURES
Wet location covers for FS/FD boxes.
UL Listed for wet locations (cover closed) damp
locations (cover open or closed).
Wet Location Covers for Power-Lock®Receptacles
Die Cast Aluminum and Glass Filled Nylon Covers for Power-Lock® Receptacles
Description Catalog No.
Die cast aluminum lift lid cover for 3 wire 20 amp receptacles. 23007
Red glass filled nylon lift lid cover for 4 wire 30 amp receptacles. 20446N
Gray glass filled nylon lift lid cover for 4 wire 30 amp receptacles. 20416N
Die cast aluminum lift lid cover for 4 wire 30 amp receptacles. 20416D
R
C
2.25" (57.2mm) internal depth
4.56"
(115.8mm)
3.25"
(82.6mm)
4.56"
(115.8mm)
2.41"
(61.2mm)
1.88"
(47.8mm)
2.85"
(72.4mm)
2.84"
(72.1mm)
1.87"
(47.5mm)
1.19"
(30.2mm)
4.69" (119.1mm)
3.29"Dia. (83.6mm)
3.25" (82.6mm)
3.59"
(91.2mm)
1.87"
(47.5mm)
2.84"
(72.1mm)
4.56" (115.8mm)
3.25" (82.6mm)
Loading...