remove Owner's Manual & Assembly
Instructions from main carton of your
storage building and locate Interior
Dimensions on the front cover.
Kit fits all 10' wide mid wall braced
ARROW storage buildings produced
since 1979. Kit can be adapted easily
for buildings with no mid wall frame,
for older buildings and buildings by
other manufacturers by drilling as
needed.
Remove the parts from the carton
and lay them out in similar groups
with the part numbers facing up.
Check the part numbers and quantity
with the parts list.
Before you start, read the entire
manual to plan how you want to use
your Attic Kit.
65103
#8-32 Hex Nut (48)
#8-32x3/8” Bolt (48)
65923
Keep this Owner's Manual for future reference.
* If you find a part is missing, include the model no. of your kit and contact:
Arrow Group Industries, Inc.
Customer Service Department
Route 50 East Breese, Illinois 62230
1-800-851-1085
PartPart QuantityCheck
NumberDescription in Carton List
8225 Post 8
8226 Long Attic Channel 4
8227 Short Attic Channel 2
704970807
CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE
TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP.
WEAR GLOVES WHEN HANDLING METAL PARTS.
Step 1
TQ02
1 Position long attic channels as
shown. Interlock channels and telescope them to proper dimension for
your building. Align holes and fasten
together using bolts and nuts. See
Fig. 1. Make two complete assemblies using correct interior width.
LONG ATTIC CHANNEL 8226
INTERIOR WIDTH
115 1/4" (2,92m)
INTERIOR WIDTH
118 1/4" (3m)
INTERIOR WIDTH
118 5/8" (3,01m)
FIGURE 1
8226
2
Step 2
TQ03
1 Install two posts at the rear corner
of building by removing the two fasteners in the framework. Interlock the
two posts and telescope them to the
proper length between the upper and
mid wall frames. Tabs on ends of
posts go behind frames. Reinsert top
and bottom fasteners. Fasten posts
together using a bolt and nut at the
center of posts.
2 Install the next two posts at either
26 3/8", 27 3/8" or 28 3/4" dimension
(depending on your building) toward
the front and remove the two fasteners as before. When complete, repeat procedure on the opposite side
of building in the same manner.
REAR
26 3/8" (67 cm)
27 3/8" (70 cm)
28 3/4" (73 cm)
FRONT
UPPER FRAME
POST 8225
REMOVE AND REINSERT
FASTENER
TAB
MID WALL FRAME
FOR BUILDINGS WITH NO MID WALL FRAME:
Install posts in the same manner. Using hole in bottom tab on post as a guide,
drill 1/4" diameter hole through side wall panel and fasten with a bolt and nut.
REAR
3
Step 3
TQ04
1 Position long attic channel assem-
blies at the desired height to the posts
and fasten using two or three bolts
and nuts on both sides.
2 Repeat procedure on next posts,
making sure channels are level by
using the same set of holes on each
post.
POST
LEVEL
LONG ATTIC CHANNEL ASSEMBLY
POST
4
Step 4
TQ05
1 Position short attic channels be-
tween long channels as shown. Depending on width of the wall panel on
your building, follow one of three procedures below, fastening channels
with four bolts and nuts.
2 DIAGONAL PROCEDURES
LONG ATTIC CHANNEL ASSEMBLY
SHORT ATTIC CHANNEL 8227
STRAIGHT PROCEDURE
5
Horizontal Siding Buildings
TQ06
If you are installing the Attic Kit in a Horizontal Siding building, drilling of the siding with a 1/4" diameter drill
will be necessary if building is already assembled. If there are no holes in the framework, drilling will be
required. Start your first hole approximately 9" from the corner of building and your next hole at 26 3/8" toward
the front of building.
In all cases use bolts and nuts at the upper frames as shown. Position tab on end of post on the inside of the
upper frame. Depending on the style of your building, fasten bottom of posts as shown.
When mid wall frames are offset from siding, reverse the bottom post so that the tab is on the inside, opposite
the upper tab. Fasten tab to mid wall frame using a bolt and nut.
IF BUILDING IS ALREADY ASSEMBLED
UPPER
FRAME
POST
INSIDE BUILDING
REVERSE POST
MID WALL BRACE
DRILL SIDING
1/4” (0,6 cm) DIA DRILL
SIDING
POST
INSIDE BUILDING
POST
MID WALL FRAME
UPPER
FRAME
DRILL SIDING
1/4” (0,6 cm) DIA. DRILL
SIDING
FOR BUILDINGS WITH NO MID WALL FRAME:
Telescope posts to line up tab on bottom post with flat
spot in siding panel. Fasten posts together with a bolt
and nut. Using hole in bottom tab as a guide, drill 1/4"
diameter hole through siding panel and fasten using a
bolt and nut.
6
IMPORTANT CAUTION NOTE
The Universal Attic Storage Kit was designed to support weight equally spaced over the entire kit. The
total weight of all shelving on the walls is a 250 lb. load limit. Caution should be kept in mind at all times
as to the weight of the material being stored on this kit. The manufacturer assumes no responsibility for
failure or personal injury.
TQ07
Channels can be
adjusted to 5 heights
Drill channels and hang hooks from
them for various tools
1
2
3
4
5
Cover with wood and use
as a work bench
7
TQ08
Other Uses
Kit can be attached through the sheet rock into studs or directly to studs using at least a #10 wood screw.
•Garage – Add extra storage space up and out of the
way with an attic kit hung from rafters or beams.
World's Leading Maker
of Storage Buildings®
8
•Basement Storage – Attach tops of posts to rafters.
Set channels at lowest position to store items safely
off damp floor.