Arrow NK1174 Assembly Instructions

Owner's Manual & Assembly Instructions
TQ01
Universal Attic Kit Model No. AT101
IMPORTANT: Before you start,
remove Owner's Manual & Assembly Instructions from main carton of your storage building and locate Interior Dimensions on the front cover.
Kit fits all 10' wide mid wall braced ARROW storage buildings produced since 1979. Kit can be adapted easily for buildings with no mid wall frame, for older buildings and buildings by other manufacturers by drilling as needed.
Remove the parts from the carton and lay them out in similar groups with the part numbers facing up. Check the part numbers and quantity with the parts list.
Before you start, read the entire manual to plan how you want to use your Attic Kit.
65103
#8-32 Hex Nut (48)
#8-32x3/8” Bolt (48)
65923
Keep this Owner's Manual for future reference.
* If you find a part is missing, include the model no. of your kit and contact:
Arrow Group Industries, Inc. Customer Service Department Route 50 East Breese, Illinois 62230 1-800-851-1085
Part Part Quantity Check Number Description in Carton List
8225 Post 8 8226 Long Attic Channel 4 8227 Short Attic Channel 2
704970807
CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. WEAR GLOVES WHEN HANDLING METAL PARTS.
Step 1
TQ02
1 Position long attic channels as
shown. Interlock channels and tele­scope them to proper dimension for your building. Align holes and fasten together using bolts and nuts. See Fig. 1. Make two complete assem­blies using correct interior width.
LONG ATTIC CHANNEL 8226
INTERIOR WIDTH
115 1/4" (2,92m)
INTERIOR WIDTH
118 1/4" (3m)
INTERIOR WIDTH
118 5/8" (3,01m)
FIGURE 1
8226
2
Step 2
TQ03
1 Install two posts at the rear corner
of building by removing the two fas­teners in the framework. Interlock the two posts and telescope them to the proper length between the upper and mid wall frames. Tabs on ends of posts go behind frames. Reinsert top and bottom fasteners. Fasten posts together using a bolt and nut at the center of posts.
2 Install the next two posts at either
26 3/8", 27 3/8" or 28 3/4" dimension (depending on your building) toward the front and remove the two fasten­ers as before. When complete, re­peat procedure on the opposite side of building in the same manner.
REAR
26 3/8" (67 cm) 27 3/8" (70 cm) 28 3/4" (73 cm)
FRONT
UPPER FRAME
POST 8225
REMOVE AND REINSERT
FASTENER
TAB
MID WALL FRAME
FOR BUILDINGS WITH NO MID WALL FRAME: Install posts in the same manner. Using hole in bottom tab on post as a guide, drill 1/4" diameter hole through side wall panel and fasten with a bolt and nut.
REAR
3
Step 3
TQ04
1 Position long attic channel assem-
blies at the desired height to the posts and fasten using two or three bolts and nuts on both sides.
2 Repeat procedure on next posts,
making sure channels are level by using the same set of holes on each post.
POST
LEVEL
LONG ATTIC CHANNEL ASSEMBLY
POST
4
Step 4
TQ05
1 Position short attic channels be-
tween long channels as shown. De­pending on width of the wall panel on your building, follow one of three pro­cedures below, fastening channels with four bolts and nuts.
2 DIAGONAL PROCEDURES
LONG ATTIC CHANNEL ASSEMBLY
SHORT ATTIC CHANNEL 8227
STRAIGHT PROCEDURE
5
Horizontal Siding Buildings
TQ06
If you are installing the Attic Kit in a Horizontal Siding building, drilling of the siding with a 1/4" diameter drill will be necessary if building is already assembled. If there are no holes in the framework, drilling will be required. Start your first hole approximately 9" from the corner of building and your next hole at 26 3/8" toward the front of building.
In all cases use bolts and nuts at the upper frames as shown. Position tab on end of post on the inside of the upper frame. Depending on the style of your building, fasten bottom of posts as shown.
When mid wall frames are offset from siding, reverse the bottom post so that the tab is on the inside, opposite the upper tab. Fasten tab to mid wall frame using a bolt and nut.
IF BUILDING IS ALREADY ASSEMBLED
UPPER FRAME
POST
INSIDE BUILDING
REVERSE POST
MID WALL BRACE
DRILL SIDING
1/4” (0,6 cm) DIA DRILL
SIDING
POST
INSIDE BUILDING
POST
MID WALL FRAME
UPPER FRAME
DRILL SIDING
1/4” (0,6 cm) DIA. DRILL
SIDING
FOR BUILDINGS WITH NO MID WALL FRAME: Telescope posts to line up tab on bottom post with flat spot in siding panel. Fasten posts together with a bolt and nut. Using hole in bottom tab as a guide, drill 1/4" diameter hole through siding panel and fasten using a bolt and nut.
6
IMPORTANT CAUTION NOTE
The Universal Attic Storage Kit was designed to support weight equally spaced over the entire kit. The total weight of all shelving on the walls is a 250 lb. load limit. Caution should be kept in mind at all times as to the weight of the material being stored on this kit. The manufacturer assumes no responsibility for failure or personal injury.
TQ07
Channels can be
adjusted to 5 heights
Drill channels and hang hooks from
them for various tools
1
2
3
4
5
Cover with wood and use
as a work bench
7
TQ08
Other Uses
Kit can be attached through the sheet rock into studs or directly to studs using at least a #10 wood screw.
Garage – Add extra storage space up and out of the way with an attic kit hung from rafters or beams.
World's Leading Maker of Storage Buildings®
8
Basement Storage – Attach tops of posts to rafters. Set channels at lowest position to store items safely off damp floor.
704970807