A.R.I. NR-030 User Manual

NR
-
MAINTENANCE INSTRUCTIONS
GENERAL INSTRUCTIONS
1. Routine service is an integral part of the standard procedure for maintenance of a water supply system.
2. Recommended routine maintenance– once or twice a year, according to the quality and kinds of the fluids in the system.
A. Installation
The valve can be installed either horizontally or vertically ,
while the flow is toward the upper part.
The counter weight assembly (11) will be installed so the
arm turns down at a 450 angle when the valve closes.
Shut-off valve – in order to allow maintenance and removal
of the valve, a shut-off valve will be installed before the inlet and / or after the outlet of the valve, according to the conditions in the pipeline.
Stainless Steel shaft (12) – it is forbidden to weld or to coat
the shaft.
B. Periodic Maintenance
1. Greasing of the bolt and key of the counter weight.
2. Brush painting of the surface area of the valve body.
A.R.I FLOW CONTROL ACCESSORIES
KIBBUTZ KFAR CHARUV 12932 WWW.arivalves.com TEL. 972-4-6761988 FAX. 972-4-6763402 E.MAIL: ari@ari.co.il
N-030
Symptom Cause Corrective action
1 The seats no properly sealed
(reverse flow occurring)
2 Leakage from the shaft O-
3 Leakage between the body
and the plugs
1) Hard solid stuck on the seats
2) Elastomer deterioration.
3) Exaggerated clearance between the internal parts due to Erosion
1) O-ring Elastomer
Ring
deterioration.
2) Shaft Erosion at O-rings contact
The fiber seal broken. Replace the fiver seal.
1) Dismantle the N-030 from the line and clean both the two seats surfaces.
2) As above and change the
elastomer seal.
3) Change the complete disc
and arm assembly
1) Change the O-rings plugs.
2) Replace the complete shaft.