Installation and Maintenance of A.R.I.’s D-015 Combination Air Valves
A. Installation
A.1
A.2
B. Basic, Periodic, Maintenance
B.1 Shut the isolating valve below the air
valve. B.2 Unscrew the cover’s bolts of the automatic air valve (10) slowly,to
release accumulated pressure .
B.3 Remove the plastic cover of the automatic a.r.v. (1) with
screwdriver , clean the orifice (4) with flowing water and with thin copper wire . Wash the inside of the body(12), the float(11), and the Rolling Seal (6), with clean water .
B.4 Check to make sure the Rolling Seal is unharmed (not torn or
cracked) .
B.5 Reinstall in reverse order and fasten and tighten all bolts. Make sure
to re-assemble all the components correctly.
B.6 Unscrew the bolts (20) that connect the main valve cover (14) to its
body (18).
B.7 Wash the body and the cover in clean water in order to remove
coarse grime or accumulated scale.
B.8 Reinstall in reverse order and fasten and tighten all bolts. Make sure
to re-assemble the upper air valve correctly: B.9 Open the isolating valve beneath the air valve.
Tel. 972-4- 6761980 Fax.972-4- 6763402
A.R.I FLOW CONTROL ACCESSORIES
Page 2
Tel. 972-4- 6761980 Fax.972-4- 6763402
A.R.I FLOW CONTROL ACCESSORIES
Page 3
D. Troubleshooting
PROBLEM CAUSE SOLUTION
Leak From the Small Orifice
a. Dirt
particles
stuck in
the orifice
b. Rolling
Seal torn
a. Shut the isolating valve, wait a
minute, and open it again, very fast. If leaking continues, go to b.
b. Shut the isolating valve,
Unscrew the cover bolts of the automatic air valve, slowly, to release accumulated pressure. Remove the plastic cover with a screwdriver and clean the orifice with flowing water and with a thin copper wire. Wash the inside of the body, the float, and the Rolling), with clean water
c. Check to make sure the Rolling
Seal is unharmed (not torn or cracked). Replace the Rolling
Seal if needed. Leak From the Large Orifice
Dirt particles stuck on the orifice seal,
a. Shut the isolating valve, wait a minute, and open it again, very fast. If leaking continues, go to b. on the orifice
seat, b. Shut the isolating valve, unscrew
the or on the
float. air valve cover bolts, remove the
cover, and remove float. Check if
the seal, the seat, or the float are
dirty, and clean them.