Argox FM-201
Integration Manual
0

Contents
1. About FM-201 Scan Engine ..................................................................................... 2
2. Signal Connector ...................................................................................................... 4
2.1. J2 Connector ................................................................................................. 5
2.2. Interface Connector ...................................................................................... 7
3. Mechanical Specifications ........................................................................................ 8
3.1. Distance from window ................................................................................. 8
3.2. Window size and material ............................................................................ 8
4. General Specification ............................................................................................. 12
5. Test .......................................................................................................................... 14
1

1. About FM-201 Scan Engine
The FM-201 Scan Engine is a small decoder that can read all popular 1D barcodes. This
device is comprised of two main parts: an optical system and a control board. The
optical system is a 2048 pixel linear imager. The control board contains firmware to
scan, decode and output barcode data. The below block diagram shows the data flow
from control board to the host.
Optical System
(LED, Condenser, Lens, chassis..)
Control Board
Interface to Host
2

The FM-201 Scan Engine is specifically designed for easy integration into your
application devices. The control module supports RS232, Keyboard wedge and USB 1.1
interface.
The control board is based on MCU to fulfill the functions of barcode scanner, image
decoding, parameter settings, and communication with host. The block diagram and
individual description are listed as below,
Txd
RxD
RTS
CTS
KBON
P8.2
Trigger Switch / P14
Buzzer / FTIOB0
Dual LED / P65,P62
Interface selection (AN4)
KBCLK
Bilateral
Switch -
74HC4066
( U3)
LED
(LED1,2 )
C
C
D
( J1)
10P
MCU
TG(P76)
P1(P75)
P2(P74)
(U1 )
AIN0
connector
( J2 )
14P
SCL
EEPROM-
(U2)
SDA
PS2 CLK (P80)
PS2 Data(P81)
3

2. Signal Connector
The control module is reserved connection pins for interface, trigger, buzzer, LEDs and
power. J2 is comprised of 14 pins that start from right to left, pin1 to pin 14. The
diagram and description are listed as below:
4

2.1. J2 Connector
Pin Description Example
1 GND.— Supply signal ground
2 RTS ( To Host ) / CLK/KB.— TTL level
232 Request to send
3 RxD ( From Host ).— TTL level 232
receive data
4 CTS ( From Host ) / DATA/KB.— TTL
level 232 Clear to Send signal.
5 DATA/PC ( PS2 DATA ).
6 CLK/PC ( PS2 CLK ).
7 TxD ( To Host ).—TTL level 232
transmit data.
8 5 V DC input—Supply voltage input.
9 I/F identification . According to the
voltage level at I/F, the scanner will
automatically select a communication
Interface, when the interface selection of
scanner being set at auto-detection
mode.
The followings list the interface
selection corresponding to the various
Wire I/F with a 4.7K then ground
R4
4.7K/0603
voltage level at I/F.
I/F floating-NC: Identified as RS232
I/F short to GND: Identified as
Keyboard wedge. Wire I/F with a
4.7K then ground : Identified as USB
10
Trigger Switch(SW1)
To trigger off a scanning operation..
P14 of CPU is wired to the SW1 to read
the SW1 status, pressed or released.
SW1
GND
GND
1
3
Tack Switc h
2
4
TRIGEER
TRIGEER
STS-KB5
SERIES
5

11
Buzzer
To provide the indication of sound.
The generation of frequency & duty
( loudness) of buzzer sound is done by
Timer Z in CPU
C21
10uF
C0805
BUZZER
C22
0.1uF
C0603
R7
1K
R0603
Buzzer
1
+5V
+-
3
2
R8
33R
R0603
Q2
2N2222
SOT- 23
D2
1N4148
SOD80C
12 GRE_LED.
Dual LED (LED3)
Dual Red&Green LED for indication.
13 RED_LED.
Dual LED (LED3)
Dual Red&Green LED for indication.
14 N.C.
R33
220R
R0603
RED_LED
GRE_LED
+5V
R9
220R
R0603
Red/Greed LED
LED4
5690F_0 D ual LED
6

2.2. Interface Connector
The control board to host interface signals have different definitions depending on the
operation of RS232, keyboard wedge or USB.The signals are listed as below:
Pin Signal RS232 K/B USB
1 GND GND GND GND
RTS(CLK KB) RTS
2
3 RxD RxD X X
CTS(DATA KB) CTS
4
5 DATA PC X DATA PC DATA PC
6 CLK PC X CLK PC CLK PC
7 TxD TxD X X
8 Vcc(DC 5V) Vcc(DC 5V) Vcc(DC 5V) Vcc(DC 5V)
9 I/F I/F I/F I/F
10 Trigger X X X
11 Buzzer X X X
12 GRE_LED X X X
13 RED_LED X X X
14 NC X X X
CLK KB
DATA KB
X
X
7

3. Mechanical Specifications
3.1. Distance from window
The window should be mounted close to the front of the Scan Engine. The maximum
distance is measured from the Scan Engine housing to the farther surface of the window.
The unwanted reflections can occur at either surface and the window thickness can vary,
the further side is the worse case.
3.2. Window size and material
1. Window material must be clear and anti-scratch. Clarx, Polycarbonate and CR39 are
preferred.
2. The recommended thickness of window is from 1mm to 15 mm.
3. The recommended distance is from 10 mm to 35 mm between window and engine.
4. The recommended angle is from 0 to 28 degree .
5. The window size must increase as it is moved away from the engine to the
accommodate illumination.
8

Window Distance and Angle Diagram
Window Size and Distance Diagram
9

Window Size Diagram ( LED Aimer)
10

FM-201 Engine Bracket Mounting
The illustration below show the mechanical mounting dimensions for the FM-201
11

4. General Specification
Item Specification
Scanning system Red LED light source. 2048 pixels CCD.
Resolution 4 mil (0.10mm).
Scan angle
Pitch: <60° (EAN13, 13mil, 35 mm wide , PCS=90%)
Yaw: <70°
Depth of field Ambient lux: 300 +/-30 lux (fluorescent lamp).
PCS = 90%.
Resolution Near field Far field
4 mil (Code 39, 1:2.5) , 45mm 70mm
5 mil (Code 39, 1:2.5) 45mm 80mm
10 mil (Code 39, 1:2.5)43mm 45 mm
125mm
13 mil (Code 39, 1:2.5)83mm 90mm 155mm
20 mil (Code 39, 1:2.5)95mm 100mm 195mm
13 mil (UPC/EAN) 45 mm 155mm
PCS =45%. (Argox Test Chart) < note 1>
Resolution Near field Far field
4 mil (Code 39, 1:2.5) X
5 mil (Code 39, 1:2.5) 45mm 60mm
13 mil (Code 39, 1:2.5) 90mm 110mm
20 mil (Code 39, 1:2.5) 105mm 140mm
13 mil (UPC/EAN) 45 mm 115mm
Resolution Data
4 mil (Code 39, 1:2.5) 09876
5 mil (Code 39, 1:2.5) 01234
10 mil (Code 39, 1:2.5)43mm ARGOX-123
13 mil (Code 39, 1:2.5)83mm 83MM CODE-39-1
20 mil (Code 39, 1:2.5)95mm 95MM -CODE
13 mil (UPC/EAN) 471987654321
Scan rate 30~100 sacn/second, auto adaptive.
PCS >= 45%
12

Reading indication LED and adjustable beep sound (Add LED&Buzzer yourself)
Industrial 2 of 5, Interleaved 2 of 5, Standard 2 of 5, , Matrix 2 of
Symbologies Code-11, Code-39, Code-93, Code-128, Codabar, EAN-8/13
(with add-on), UPC-A/E UPCE (with add-on).
MSI/Plessey ,UK/Plessey, Telepen
5 Eur.China postage. Italian Pharmacy code (code-32).
RSS-14, RSS-limited, RSS-expanded.
Power supply Operating range: 5 VDC +/-0.25 (Scanner only)
Power consumption:
Scanning: Max.: 250 mA (Test Mode).
Typical: Max.: 200 mA (Momentary Mode)
Standby: Max.: 60 mA
Environments
Operating temp.: 0~50 °C
Storage temp.: -20~+70 °C
Ambient LUX.: 0~20000 Lux
13

The illustration below show s a unit similar to the unit tested.
14