Arecont Vision AV10355PMIR-SH, AV10355PMTIR-SH, AV1355PM-S, AV1355PMIR-S, AV2355PM-H Installation Manual

...
!
MegaDome® G3
Installation Manual
1.2 Megapixel
AV1355PM-S
AV1355PMIR-S
1080p
AV2355PMIR-SH
AV2356PMIR-S
AV2355PMIR-SAH
AV2355PMTIR-SH
AV2356PMTIR-S
3 Megapixel
AV3355PMIR-SH
AV3356PMIR-S
AV3356PMIR-SA
AV3355PMTIR-SH
AV3356PMTIR-S
5 Megapixel
AV5355PMIR-SH
AV5355PMIR-SAH
AV5355PMTIR-SH
10 Megapixel
AV10355PMIR-SH
AV10355PMTIR-SH
Installation Manual
Page | 2 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Contents
!
Package Contents .................................................................................................................................... 3
Camera Overview ..................................................................................................................................... 6
Installation ................................................................................................................................................. 7
Surface Mount ..................................................................................................................................... 10
Wall Mount .......................................................................................................................................... 13
Pendant Mount ................................................................................................................................... 16
Pole Mount .......................................................................................................................................... 19
Corner Mount ...................................................................................................................................... 21
Electrical Box Adapter ........................................................................................................................ 23
Adjusting the Pan, Tilt and Focus ........................................................................................................... 24
Auxiliary I/O Functions ............................................................................................................................ 26
Camera Power Up .................................................................................................................................. 28
SD Card Set-up ...................................................................................................................................... 30
SD Card Tab ........................................................................................................................................... 33
SD Card Setup via AV200 ...................................................................................................................... 34
Camera Discovery, Setup, and Configuration ........................................................................................ 35
Network Protocols ................................................................................................................................... 35
General Remote Focus ........................................................................................................................... 36
Refined Remote Focus ........................................................................................................................... 37
AV IP Utility Focus Tab ........................................................................................................................... 39
Mounting Templates ............................................................................................................................... 40
Support ................................................................................................................................................... 41
Installation Manual
Page | 3 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
!
CAUTION!
1. Do not attempt to service a damaged unit yourself. Refer all servicing to qualified service personnel.
2. Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and
with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or
Recognized wire suitable for the application.
3. Always use hardware e.g. screws, anchors, bolts, locking nuts etc. which are compatible with
mounting surface and of sufficient length and construction to insure a secure mount.
Package Contents
This equipment should be unpacked and handled with care. The original packaging is the safest
container in which to transport the unit and can be used if returning the unit for service. The packaging
contains:
10
8
9
11
12
13
Installation Manual
Page | 4 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
!
Reference #
Description
1
1x Arecont Vision MegaDome® G3 camera
2
1x Dome Cover
3
1x Mounting Plate
4
1x Grommet with Through Hole
5
1x Grommet without Through Hole
6
1x Insertion Tool
7
4x #6-32 1.0” Wood/ Metal Sheet Screw 8
4x #6-32 1.0” Drywall/ Masonry Mounting Anchors
9
4x #8-32 0.5” Machine Screw
10
1x Security L-key
11
1x Set Screw L-key
12
1x Mounting Template
13
1x Magnetic core
1x I/O cable
1x AC & DC auxiliary power cable
1x CD with Manual and Software
!
!
!
!
!
!
!
!
Installation Manual
Page | 5 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Warranty Information
Global (3 Year) Limited Warranty
ARECONT VISION warrants to Purchaser (and only Purchaser) (the “Limited Warranty”), that: (a) each Product shall be free from material defects in material and workmanship for a period of thirty-six (36) months from the date of shipment (the “Warranty Period”); (b) during the Warranty Period, the Products will materially conform with the specification in the applicable documentation; (c) all licensed programs accompanying the Product (the “Licensed Programs”) will materially conform with applicable specifications. Notwithstanding the preceding provisions, ARECONT VISION shall have no obligation or responsibility with respect to any Product that (i) has been modified or altered without ARECONT VISION’s written authorization; (ii) has not been used in accordance with applicable documentation; (iii) has been subjected to unusual stress, neglect, misuse, abuse, improper storage, testing or connection; or unauthorized repair; or (iv) is no longer covered under the Warranty Period. ARECONT VISION MAKE NO WARRANTIES OR CONDITIONS, EXPRESS, IMPLIED, STATUTORY OR OTHERWISE, OTHER THAN THE EXPRESS LIMITED WARRANTIES MADE BY ARECONT VISION ABOVE, AND ARECONT VISION HEREBY SPECIFICALLY DISCLAIMS ALL OTHER EXPRESS, STATUTORY AND IMPLIED WARRANTIES AND CONDITIONS, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT AND THE IMPLIED CONDITION OF SATISFACTORY QUALITY. ALL LICENSED PROGRAMS ARE LICENSED ON AN “AS IS” BASIS WITHOUT WARRANTY. ARECONT VISION DOES NOT WARRANT THAT (I) THE OPERATION OF THE PRODUCTS OR PARTS WILL BE UNINTERRUPTED OR ERROR FREE; (II) THE PRODUCTS OR PARTS AND DOCUMENTATION WILL MEET THE END USERS’ REQUIREMENTS; (III) THE PRODUCTS OR PARTS WILL OPERATE IN COMBINATIONS AND CONFIGURATIONS SELECTED BY THE END USER; OTHER THAN COMBINATIONS AND CONFIGURATIONS WITH PARTS OR OTHER PRODUCTS AUTHORIZED BY ARECONT VISION OR (IV) THAT ALL LICENSED PROGRAM ERRORS WILL BE CORRECTED.
For RMA and Advance Replacement information visit http://www.arecontvision.com
!
Installation Manual
Page | 6 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Camera Overview
MegaDome® G3 third generation multi-megapixel cameras provide ample resolution to zoom-in for
details in live or recorded video. These indoor/outdoor all-in-one solutions integrate a 1.3, 1080p, 3, 5
or 10-megapixel (MP) sensor with fast frame rates, and SNAPstream™ (Smart Noise Adaptation and
Processing) technology to reduce bandwidth without impacting image quality. Together with an IR
corrected motorized, P-iris wide angle or telephoto varifocal lens, remote focus and remote zoom make
MegaDome G3 easy to install and manage. The installer-friendly housing is IP66 environmental rated
and IK-10 impact-resistant. MegaDome G3 is feature-loaded, and select models include STELLAR™
(Spatio Temporal Low Light Architecture) for best-in-class light sensitivity capturing details in near
complete darkness, or wide dynamic range (WDR) for applications with bright or over saturated lighting
conditions.
Installation Manual
Page | 7 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Installation
!
1. Determine a secure location to mount the camera.
2. Use the supplied security L-key, to loosen the four (4) screws securing the dome cover.
3. Remove the dome cover and protective foam. Do not remove screws from the dome cover.
The MegaDome® G3 camera has been designed to provide installers with flexible mounting options such as ceilings, walls, poles or corners.
NOTE: When mounting the camera outdoors or in a wet environment, use of supplied grommet is recommended. Ensure the grommet properly seated flush with the camera housing.
Installation Manual
Page | 8 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Ensure you have the proper compatible mounting parts prior to starting your installation:
!
Pendant mount
Reference #
Pendant Mount Components Required
1
Pendant mount (AV-PMJB) with integrated junction box
2
MegaDome® G3 camera
3
MD-CAP mounting cap
!
!!!!!!!!
!
Wall mount
Reference #
Wall Mount Components Required
1
Wall mount (AV-WMJB) with integrated junction box
2
MegaDome® G3 camera
3
MD-CAP mounting cap
Installation Manual
Page | 9 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
!
Pole mount
Reference #
Pole Mount Components Required
1
Wall mount (AV-WMJB) with integrated junction box
2
MD-CAP mounting cap
3
MegaDome® G3 camera
4
AV-PMA pole mount adapter
!
!
Corner mount
Reference #
Corner Mount Components Required
1
Wall mount (AV-WMJB) with integrated junction box
2
MD-CAP mounting cap
3
MegaDome® G3 camera
4
AV-CRMA corner mount adapter
4. Use the Arecont Vision software AV IP Utility located on the CD or available for download at our website (www.arecontvision.com) for camera discovery and setup (see Instruction Manual located on the CD or available on our website).
Installation Manual
Page | 10 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Surface Mount
The MegaDome® G3 camera can be directly attached onto hard ceilings or walls including wood, plastic, metal and concrete.
1. Use the template, anchors, and screws provided to prepare the mounting provisions for the camera installation.
2. Use the supplied security L-key, to loosen the four (4) tamper resistant screws securing the dome cover as shown in Figure 1. Do not remove screws from the dome cover.
Figure 1
3. Remove the protective foam and discard.
4. Install four supplied dry wall anchors using the supplied mounting template.
5. Align four supplied screws with the dry wall anchors and screw mounting plate into place as shown in Figure 2.
!
Figure 2
Installation Manual
Page | 11 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
6. Prepare the network cable with the supplied grommet and insertion tool as shown in Figure 3.
Figure 3
NOTE: When mounting the camera outdoors or in a wet environment, use of supplied grommet is recommended. Ensure the grommet is properly seated flush with the camera housing.
7. Align the hole on MegaDome® G3 camera with the hole on mounting plate, and install the grommet on camera housing as shown in Figure 4.
!!
Figure 4
NOTE: If using the side connection of the NPT port, you need to install the supplied grommet without a through hole on the camera housing, and remove the cap covering the side entrance, otherwise; leave the cap in place. If using the NPT port, always use Teflon tape around the threads to ensure proper sealing. The conduit fits ¾” NPT standard. Ensure NPT port is facing downward.
Installation Manual
Page | 12 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
8. Fasten securely four captive screws as shown in Figure 5.
!
Figure 5
9. Attach the Dome Cover to the MegaDome® G3 camera and fasten securely four captive screws.
NOTE: When attaching the Dome Cover, make sure the IR foam on the lens not block the field of view.
10. To configure the camera, reference the camera discovery, set-up and configuration section.
!
CAUTION! The captive screws must be used to properly secure the dome cover and
camera housing. Failure to use the captive fastener may result in serious injury. When mounting the dome cover to the camera housing, ensure that the gasket is properly seated and not folded. Failure to do so may result in water and dust ingress. Water damage from improper installation is not covered by the warranty!
!
!
!
!
!
!
!
!
!
!
Installation Manual
Page | 13 support@arecontvision.com
! !
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
MegaDome® G3
Wall Mount
For a proper wall mount installation, the AV-WMJB wall mount and MD-CAP wall mount cap are required (sold separately). A wall mount should only be attached onto hard ceilings including wood, plastic, metal, and concrete.
1. Using the Mounting template, prepare the mounting provisions for the camera installation.
2. Connect wall mount cap and wall mount as shown in Figure 1.
Figure 1: Attach wall mount cap to the wall mount
NOTE: The thread size for Top shield, pendant pole and mount is 1.5” NPT.
3. Attach the wall mount to the wall using the four drywall screws provided or any optional hardware suitable for the mounting surface.
4. Run the Ethernet Cable and outside power cable (if necessary) through the supplied rubber gasket and then through the wall mount. Ensure the gasket is seated properly.
5. Attach the mounting plate to the MD-CAP with the supplied screws as shown in Figure 2.
Figure 2