AquaMetrix SHARK TXP Data sheet

Aquametrix SHARK TX / TXP
Aqua
by
Water Analytics
Aqua
Metrix
Multi-Parameter Transmitter
Features
pH, ORP, Conductivity &
Flow parameters available
24 VDC / 24 VDC Loop
Easy to read 2 X 16 char-
acter LCD display
Quick and easy to calibrate
Single 4-20mA output with
range expandability
1/4 DIN size, NEMA 4X
polycarbonate housing
Shark-TX: Universal
mounting hardware provided for surface, panel and pipe mounting
Description
SUMMARY
Complete and versatile, SHARK-TX is the only 1/4 DIN and DIN rail mount­able two wire transmitter on the mar­ket that allows the user to select one of four measuring parameters.
FOUR MEASURING PARAMETERS
Select the parameter you wish to mea­sure from the easy-to-use LCD menu on the front cover. Choose Conductiv­ity, pH, ORP or Flow.
COMPLETE - NO EXTRA CARDS OR OPTIONS REQUIRED
Each SHARK-TX comes complete. There are no extra costs associated with buying boards for different appli­cations.
TWO MOUNTING OPTIONS
SHARK-TX comes complete with a universal mounting kit for surface, panel and pipe-mount applications. The NEMA 4X 1/4 DIN enclosure is perfect for stand-alone or panel-mount operation. SHARK-TXP is NEMA 4X for front
panel mounting and comes complete with DIN rail mounting hardware for mounting in a control panel.
DISPLAY
2-line, 16-character LCD on the front panel.
ANALOG OUTPUTS
The SHARK-TX provides an isolated and fully scalable 4-20 mA output.
ENCLOSURE
SHARKTX is packaged in a rugged NEMA 4X polycarbonate enclosure making it ideally suited for heavy-duty applications such as industrial waste­water neutralization, municipal water and wastewater, pulp and paper, and process control. The SHARKTXP enclosure is also polycarbonate with a NEMA 4X front panel, and DIN rail mounting hardware on the back.
Shark-TXP: Panel or DIN
rail mounting hardware pro­vided
Applications
Process Control
Industrial and Municipal
Water Treatment
Industrial and Municipal
Waste Treatment and Neutral-
ization
Fume Scrubbers
Suitable for the Plating, Circuit
Board Manufacturing, Food and Beverage, Chemical Processing, Pulp & Paper, Mining, Nuclear Energy and Pharmaceutical In­dustries
by
100 School Street
Andover, MA 01810
Toll free: 855-747-8723
www.WaterAnalytics.net
Metrix
Water Analytics
978-749-9949
SHARK TX/P pH, ORP, Conductivity, Flow Transmitter
Technical Data
pH ORP Conductivity Flow
Display
Measuring Range
Temperature
Compensation
Temperature Unit
Temperature Sensor
Calibration modes
Ambient Conditions
Sensor to Trans-
mitter Distance
Analog Output
Memory Back-up
Mechanical
Sensor Input
Invalid Entries
Manual Test Mode
Output Hold
Calibration Data
Auto Return
Display Damping
Net Weight
pH: 0.01 to 14.00 Temp: 0 to 100°C
or 32° to 212°F
Automatic or Manual
0 to 100°C (32° to +212°F)
User selectable: 300Ω NTC Thermistor, 3000Ω NTC Thermistor or Pt. 1000 RTD
Auto-Calibration,
Manual Calibration,
Temperature Display
Isolated Output, Range expand 0 to 100% of full scale (min segment 10% of full scale),max. load 800Ω
SHARKTX Enclosure:NEMA 4X, 1/4 DIN, polycarbonate enclosure with two 1/2” conduit holes
Probe: -600 to +600 mV
Temp. Sensor: 0 to 9999 Ω
Recall data from last calibration, calibra­tion mode, 1st&2nd accepted buffer value and probe mV output, calibration tempera-
ture, calibration slope, and probe efciency
User can select rate at which SHARK updates display. Enables display damping of unstable process
Front Panel: 4 x 7 segment 1/2” LED display, 1 LED indicator 0n-line,7 LED
Bar Graph. Inside Panel: 2 x 16 alpha-numeric LCD display
MΩ/
3
cm
µS/
3
ORP: -1999 to +1999mV
(Dependent on sensor)
Temp: 0 to 100°C
or 32° to +212°F
Not required
°C or °F Not required
Manual Calibration
Temperature Calibration
Temperature: -20°C to +60°C or -4°F to +140°F Humidity: 0 to 90% RH (non-condensing)
Differential Sensor: 3000 ft
Combination Sensor:10 ft
All user settings are retained indenitely in memory (EEPROM)
SHARKTXP Enclosure:NEMA 4X front panel, 1/4 DIN, polycarbonate
SHARKTX Mounting: Universal Mounting kit for surface, pipe and panel mount included
SHARKTXP Mounting: Panel and DIN rail mount included
Probe: -1999 to
+1999 mV
Temp. Sensor:
0 to 9999 Ω
Invalid entries cannot be stored
Process value can be simulated with arrow keys to verify correct setup of outputs
4 to 20 mA output is placed on hold when the transmitter is in Menu mode
User selectable auto return if the transmitter is left in menu mode for more than 10 min.
SHARK-TX: 0.71 lbs (0.32 kg)
SHARK-TXP: 0.25 lbs (0.12 kg)
cm
mS/
3
cm
Automatic or Manual
User selectable tempera-
ture compensation slope
0.0 to 10.0% / °C.
0 to 100°C (32° to 212°F)
Dry Calibration
Sample Calibration
Temperature Calibration
4 to 20 mA
Cell: 0 to 9999 Ω
Temp. Sensor: 0 to 9999 Ω
Recall data from last calibra-
tion, calibration buf fer ac-
cepted value and cell resistance,
calibration temperature.
0 to 19.9 0.01
0 to 2.00 0.01
0 to 20.0 0.1
0 to 200 0.1
0 to
2000
0 to 20 10
0 to 200 50
300 ft 2000 f t
1.0
Flow: 0 to 9999 with
selectable ow rate units
Volume: 0 to 9999 with
Auto Range Flow rate
units: Gallons (GP),
Cubic Feet (CF), Liters
(LP), Cubic Meters (CM),
custom by entering factor
related to Gallons.
Time units: Seconds (S),
Minutes (M), Hours (H)
Not required
K factor input
Paddle: 0 to 2000 Hz
Recall store K factor.
www.WaterAnalytics.net 978-749-9949 855-747-8723
Loading...
+ 2 hidden pages