AquaMetrix P585, R585 Data sheet

Aquametrix Model P585/R585
Water Analytics
Aqua
by
Water Analytics
Aqua
Metrix
Combination Style pH or ORP Probes
Features
Easy in: no special tools
Easy out: no twisted cable
Variable insertion length
Compact: mounts in 3/4” pipe
Universal style: Flow-
through and submersion.
Automatic temperature
compensation available
Industrial-grade quality at low cost
Description
These industrial combination pH or ORP probes use the conventional measurement technique employing a process pH glass electrode (platinum for ORP) which is compared to a reference electrode in KCL solution.
These combination probes provide an economical alternative to higher cost models. The durable materials wetted by the process provide excellent chemical resistance. The convertible design of these probes allows them to be used in ow-through and submersion applications thus minimizing inventory requirements. The probes are offered with or without temperature compensation.
These models are installed
with a 3/4” MNPT compression tting. With this design the probe does not screw into the process line but is simply inserted through the compression tting. This allows a variable insertion depth from 3/4” to 4-1/4”. Probe cleaning and system calibration is greatly facilitated.
The 585 series probes can be directly connected to the Shark,
SharkTX/P and 2200P/R analyzers, provided the instrument is within the reach of the 3 meter (10 feet) sensor cable. For longer transmission distance, preampliers suitable for automatic and xed temperature compensation are available. Refer to the next pagefor more details.
Applications
Process Control
Industrial and Municipal Water
Treatment
Industrial and Municipal Waste
Treatment and Neutralization
Fume Scrubbers
Plating
Circuit Board Manufacturing
Food and Beverage
Chemical Processing
Pulp and Paper
Mining
Power Generation
Pharmaceutical Industry
by
Andover, MA 01810
Toll free - 855-747-7623
www.WaterAnalytics.net
Metrix
100 School Street
978-749-9949
Model P585/R585 Combination Style pH or ORP Probes
Technical Data
Measuring Range
pH 0 to 14 pH (Consult factory for applica-
ORP -1000 to +1000 mV
Wetted Materials CPVC body, ceramic junction, glass elec-
Temperature Limits -5 to 80°C (23 to 176°F)
Maximum Pressure 100 psig to 65°C
Maximum Flow Rate 3 meters (10 ft.) per second
Automatic Tempera­ture Compensation
Maximum Flow Rate 3 metres (10 ft.) per sec
tions below 2 or above 12).
trode, EPDM (plus platinum for ORP)
Standard in P585K only (Ana­lyzer Dependent)
Dimensions
Stability
pH 0.05 pH per day, non-cumulative
ORP 3.0 mV per day, non-cumulative
Sensitivity
pH 0.01 pH unit
ORP 1.0 mV
Output Impedance
pH 250 Megaohms (typical)
ORP 2.0 Megaohms (typical)
Sensor Cable 3 metres (10 ft.) coaxial, terminated
with a spade lug for active electrode, other wires tinned
Related Products
CABLES & ACCESORIES
JB1 NEMA 4X junction box
101-A Encapsulated preampli-
101-A-BNC Encapsulated preamplier with BNC
C42-5P-XX X
CALIBR ATION SOLUTIONS
A35-13 pH 4 Buffer, 500 mL.
A35-14 pH 7 Buffer, 500 mL
A35-24 pH 10 Buffer, 500 mL
A35-40 ORP Buffer, 200 mV, 500 mL
A35-41 ORP Buffer, 600 mV, 500 mL
with junction box
er in NEMA 4X enclosure
connection in NEMA 4X enclosure
Interconnect cable - Dressed both ends - Specify heights in order
Ordering Information
P575/P575- BNC Industrial Combination pH probe for ow-through or
submersion application without temperature com­pensation. BNC connector is available as an option.
P575K1 Industrial Combination pH probe for ow-through
or submersion application with automatic tem­perature compensation. Compatible with Shark and SharkTX/P analyzers only. (PT1000 RTD)
P575K2 Industrial Combination pH probe for ow-through
or submersion application with automatic tem­perature compensation. (300 ohm NTC)
R575/R575- BNC Industrial Combination ORP electrode for ow-
through or submersion application. BNC connector is available as an option.