Description
Area-Velocity Flowmeter
Monitor ow through open channels, par­tially full pipes and surcharge pipes, ume or wier. Ideal for municipal stormwater, combined efuent, raw sewage and irriga­tion water.
Streamlined Sensor
The AVFM 5.0 uses a submerged ultrason­ic sensor to measure both velocity and lev­el. The sensor resists fouling, corrosion and abrasion and is tolerant of turbulence and high approach velocity. It can be congured with the standard submerged sensor, or with submerged velocity plus a non-contacting ultrasonic level sensor.
View ow rate and total ow on the large back­lit LCD display and connect to external devices with three 4-20mA outputs and two control re­lays.
Easy to Use
The AVFM 5.0 Area-Velocity Flow Meter mea­sures both Level and Velocity to calculate ow volume in an open channel or pipe. Calibration is simple: Enter the pipe ID or channel dimensions and the AVFM 5.0 computes and displays ow volume.
The ultrasonic sensor mounts inside the pipe or at the bottom of a channel. No special com­pounds, tools or hardware are required. The ultrasonic se sor is completely sealed with no orices or ports.
Recommended Pipe or Channel Conditions
Careful selection of sensor mounting location results in best performance and maintenance­free operation. Avoid locations where sediment builds up.
Best possible accuracy will result when the water is not highly turbulent and where veloc­ity is evenly distributed across the channel. The channel should not have drops or direction changes immediately upstream of the sensor mounting location. Pipe or channel slope should not exceed 3%.
The AVFM 5.0 can measure forward ow veloc­ity up to 20 ft/sec (6 m/sec) and reverse ow up to 5 ft/sec (1.5 m/sec). The electronics and soft­ware sample and average ow rates continuous­ly to provide stable readings. The submerged ve­locity/level sensor will measure ow in partially full and surcharged pipes with pressure up to 10
Metrix
Water Analytics
Area-Flow Velocity Meter
psi. No special set-up or adjustment is required. Minimum recommended pipe diameter is 6” (150 mm).
Alternate Sensor Congurations
The standard sensor measures both velocity and level with a single submerged probe. It is in­stalled in the pipe or channel oor with the stain­less steel mounting bracket (supplied), or mount­ed with an optional stainless steel band for round pipes. Alternate sensor models are available for special applications: a separate non-contacting ultrasonic level sensor with a submerged veloc­ity sensor. Sensor cable can be extended up to 500 ft (150 m).
Three 4-20 mA Outputs
Transmit to external loggers, controllers or re­mote displays. 4-20 mA outputs are congured to transmit level, velocity and ow. Outputs can be turned off for reduced power consumption (2.9 Watts minimum) or menu-congured with 0-5 VDC outputs for power consumption as low as 3.6 Watts.
Custom Channel Shapes
Calibrate the AVFM 5.0 for installation in irregu­lar or compound channel shapes by entering the channel width at multiple level points through a . Channels of virtually any shape can be moni­tored with your choice of measurement units.
Optional 2 Million point Data Logger
Choose the built-in data logger option if you want to store time and date-stamped ow values at 10 second to 60 minute intervals. Transfer log les to any USB ash drive just by connecting to the logger’s USB output. Windows software is included to display log les in graph and table formats, change measurement units and gener­ate ow reports. Export data to Excel.
Features
• One sensor measures
both velocity and level
• Displays, transmits and controls
• Measures ow in pipes and
open channels of any shape
• Measures level from 1”
to 15 ft. (2.5 cm to 4.5 m)
• 3 isolated 4-20 mA outputs
• Menu selectable op­tion for 0-5 VDC output for low power consumption
• 2 control relays
• Measures to irregu­lar shaped channels
• Measures reverse ow
• RFI rejection lters and electrical surge protection
• Optional data logger
Applications
Wastewater ow accumulation
Sewer ow monitoring and report-
ing
Inltration studies
Storm water monitoring
Natural streams
Irrigation water
by
Andover, MA 01810
Toll free - 855-747-7623
www.WaterAnalytics.net
Metrix
Water Analytics
100 School Street
978-749-9949
Model AVFM-II Area-Velocity Flow Meter
Technical Data
GENERAL SPECIFICATIONS
Channel Types Round pipe, Rectangular, trapezoid, egg
or custom shapes
Electronics Enclosure
NEMA 4X (IP 66) polycarbonate with clear, shatterproof cover
Accuracy Level: ±0.25% of Range. Velocity: ±2%
of Reading. Repeatability and Linearity: ±0.1%
Displays White, backlit matrix - displays ow rate,
totalizer, relay states, operating mode and calibration
Programming 5-key calibrator with English, French or
Spanish
Power Input 100-240 VAC 50-60 Hz, 5.28 Watts
maximum (with standard features)
Outputs 3 Isolated 4-20 mA (Flow, Level and Ve-
locity) or 0-5 VDC
Control Relays 2 Relays, form ‘C’ dry contacts 5 amp
SPDT; programmable for ow propor­tional pulse (sampler/totalizer), ow and/ or level alarm
Electrical Surge Protection
Sensor, 4-20 mA outputs and AC power input
Temp. Range. -5° to 140°F (-20° to 60°C)
Weight 10 lbs. (4.5 kg) Temperature
Compensation
Three individual LEDs i dicate status of two control relays and alarm relay
Related Products
DFM 5.0 Model DFM-5.0 Doppler Flow Meter 3200U Model 3200U Ultrasonic Level and Flow US Ultrasonic Sensor Stingray Stingray Portable Level-Velocity Logger PDFM Model PDFM-V Portable Doppler Flow Meter.
QZ02L Sensor Velocity Measure-
ment Range Level Measure-
ment Range Exposed Materials PVC, epoxy resin, polyurethane Sensor Cable 25 ft. (7.6 m) submersible polyurethane
Sensor Mounting includes MB-QZ stain-
Temp/ Comp. Automatic, continuous
OPTIONS
Date Logging
Sensor Cable
Sensor Cable Junction Box
Power Input
Analog Outputs Enclosure Heater
Intrinsic Safety Barriers
Sensors
Sensor Mount­ing Bands:
For a complete list of accessories please contact Water Analytics, 978-749-9949 or e-mail to info@WaterAnalytics.net
0.1 to 20 ft/sec (0.03 to 6.2 m/sec) and re­verse ow to -5 ft/sec (-1.5 m/sec)
Minimum Head: 1 in (25.4 mm). Maximum Head: 15 ft. (4.57 m)
jacket, shielded, 3-coaxial
less steel mounting bracket
Programmable 2 million point capacity, time-date stamped or formatted ow re­ports including Total, Average, Minimum, Maximum and Times of occurrence. In­cludes USB output.
50 ft (15 m) or 100 ft (30 m) con­tinuous from Sensor or splice up to 500 ft (150m) length
NEMA 4 steel with connec­tion terminal strip
9-32 VDC (2.5 W min., 6.5 W max.)
Three 0-5 VDC outputs Thermostatically controlled for tempera-
tures below 32°F (0°C) For Sensor mounting in Class I,II,III, Div.
I,II, Groups C,D,E,F,G hazardous loca­tions
Separate non-contacting ultrasonic level sensor and submerged velocity sensor
Stainless steel sensor mounting bands for pipes 6” to 72” (150 to 1800 mm) diameter
Submerged sensor measures both level AND velocity