AquaMetrix AS-series
by
Water Analytics
Aqua
Metri x
Conductivity Sensors
Model ASM
316SS electrodes
Model ASG
Graphite electrodes
Features
• CPVC shell
• 316 SS or Graphite Electrodes
• PT1000RTD Automatic Temperature
Compensation Device
• Adjustable Insertion Length
• AM-HTC-AS Ball Valve “Hot Tap”
Hardware Available
• Five Cell Constants to choose from:
0.01, 0.1, 1, 10 and 50
• Choice of four temperature devices for
automatic compensation
Description
For years the MS series of epoxy body
probes have been known as the most extensive conductivity probes on the market. The new AS series represent a major
upgrade.
The AS conductivity probes feature a
choice of 316 stainless steel (Model ASM)
or graphite (Model ASG) electrodes and
CPVC shells that will satisfy just about any
industrial, power plant or laboratory application. This technology insures that, with
reasonable maintenance, years of driftfree performance can be expected.
Five cell constants from 0.01 to 50 are
available to cover any water sample between pure water and saline conditions.
All types are designed with a safety stop
shoulder on the cell.
Integral automatic temperature compensation PT1000RTD is standard on all
types and provides compensation to
25°C when used with a compatible analyzer. Users can also choose between a
PT100RTD , 300 NTC or 3k NTC therm-
istor option. Either element is place to
give close thermal contact with the
liquid being measured to assure fast
response to changing temperature.
Flow-through mounting incorporates a
special compression fitting which allows
adjustable insertion length in 3/4 inch NPT
piping or in the side of a tank. This design
avoids the nuisance of disconnecting the
cell cable when installing or removing the
cell for cleaning.
Submersion mounting is achieved by reversing the direction of the compression
fitting, allowing the cell to be threaded
into the AM-ARM-AS mounting hardware.
Mounting hardware is available which includes a 4 foot length of CPVC pipe and a
simple but versatile adjustable bracket for
hanging on the rim of the tank.
AM-HTC-AS hot tap ball valve mounting
assembly with longer body sensor (HT
version) permit removal of the cell from
process piping or from tanks without
shutting down the system.
Applications
• Cooling towers
• High purity water applications
• Pharmaceutical Applications
• Reverse osmosis systems
• Food and Beverage
• Aquaculture
• Agriculture
by
Andover, MA 01810
Toll free 855-pH Probe
www.WaterAnalytics.net
Me trix
100 School Street
978-749-9949
(855-747-7623)

AS-series Conductivity Sensors
Technical Data
Measuring Range
(Depends on controller)
For AM-2250:
Wetted Materials CPVC, epoxy, EPDM, 316 Stainless Steel (for “ASM” sensors and/or “S” option for compression fitting)
Insertion type Variable insertion length, 3/4” NPT fitting
Temperature Limits 23 to 176°F (-5 to 80°C) at amospheric pressure
Maximum Pressure 100 psig at 150°F (65°C)
Temperature Compensation Standard PT1000Ω RTD. Other ATC devices available: 300NTC, PT100RTD, 3000NTC
Sensor Cable 4-conductor, unshielded, 15 ft (4.5m) standard. Up to 50ft custom cable available
Dimensions
k=001
0.2-10 µS/cm
10-500µS/cm
Optional: Graphite for ASG
k=01
100-5000 µS/cm
Temperature
k=1
k=10
5-250mS/cm
k=50
10-500mS/cm
3/4” NPT CPVC Fitting
316 SS optional
Dimension A
Insertion Depth
*not included with “HT” version
Dimension B
Total Length
Related Products
ANALYZERS
AM-2250 Multi-Parameter Controller
AM-2250TX Multi-Parameter Transmitter
ACCESORIES
AM-JB1 NEMA 4X junction box
AM-HTC-AS Ball Valve assembly for Hot-Tap insertion
AM-ARM-AS Submersion mounting kit
AM-SFL-AS 1-1/2” Sanitary flange for AS sensor
AM-TEE-AS 1” Union Tee with 3/4” adapter
AM-CCF-AS CPVC 3/4” compression fitting
AM-SCF-AS 316SS 3/4” compression fitting
CALIBRATION SOLUTIONS
AM-C010U-1P 10µS/cm, 1 pint (500 mL)
AM-C100U-1P 100µS/cm, 1 pint (500 mL)
AM-C001M-1P 1mS/cm, 1 pint (500 mL)
STAINLESS STEEL SENSORS
Conductivity
Standard 15 FT Cable
Cell
constant
Dimention A
(min/max)
Dimention B
(regular/Hot-Tap)
001 1.75 - 6” 7.25” / 11.9”
01 0.3 - 3.5” 5.8” / 10.5”
1 1.65 - 6” 5.8” / 10.5”
10 1.65 - 6” 7.35” / 12”
50 1.65 - 6 7.35” / 12”
Ordering Information
ASM1P1-015 Contacting CPVC conductivity sensor
with stainless stell electrodes, cell constant k=1 for flow-through or submersion application. PT1000RTD temperature
compensation device and 15 ft cable
ASM01P1-015 Contacting CPVC conductivity sensor
with stainless stell electrodes, cell constant k=0.1 for flow-through or submersion application. PT1000RTD temperature
compensation device and 15 ft cable
ASG10P1-015
ASM1HT1-015 Contacting CPVC conductivity sen-
Contacting CPVC conductivity sensor
with graphite electrodes, cell constant
k=10 for flow-through or submersion application. PT1000RTD temperature compensation device and 15 ft cable
sor with cell constant k=1 for use in hot
tap application. PT1000RTD temperature
compensation device and 15 ft cable
AM-series Stainless steel contacting sensors
www.WaterAnalytics.net 978-749-9949 Toll free - 855-747-7623 (855-pHProbe)