APW Wyott HFW-AT-5D User Manual

R
INSTALLATION
OPERATING
INSTRUCTIONS
Model HFW-AT-3 Shown
Models: thruHFW-AT-2 6 & HFW-AT-2D 6Dthru
Hot Food Well w/Bottom Mounted Control
INTENDED FOR OTHER THAN HOUSEHOLD USE
RETAIN THIS MANUAL FOR FUTURE REFERENCE
TOASTER MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the Installation, Operating and Maintenance Instructions thoroughly before installing or servicing this equipment.
Initial heating of appliance may generate smoke or fumes and must be done in a well ventilated area. Overexposure to smoke or fumes may cause nausea or dizziness.
This equipment has been engineered to provide you with year-round dependable service when used according to the instructions in this manual and standard commercial kitchen practices.
P/N 67208 9/05
Phone: Fax: (214) 565-0976 Toll Free: (800) 527-2100 Website: www.apwwyott.com E-mail: info@apwwyott.com
(214) 421-7366
APW WYOTT
729 Third Avenue
Dallas, TX 75226
!!
!!
1
IMMEDIATELYINSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier.
A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then
be signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carriercan supply the necessary forms.
B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for
inspection must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to holdall contents and packaging material.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instructions.
APW Wyott takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment. To ensure best results, it isimportant that you read and follow the instructions in this manual carefully. Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instruction. If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department APW Wyott Foodservice Equipment Company, 729 Third Avenue, Dallas, TX 75226.
SAFETY PRECAUTIONS
Before installing and operating this equipment be sure everyone involved in its operation are fully trained and are aware of all precautions. Accidents and problems can result by a failure to follow fundamental rules and precautions.
The following words and symbols, found in this manual, alert you to hazards to the operator, service personnel or the equipment. The wordsare defined as follows:
DANGER:
!
WARNING:
!
seriousinjuryordeath.
CAUTION:
moderateinjury orproduct orproperty damage.
!
Thissymbol warnsof imminenthazard whichwill result in serious injuryor death.
This symbol refers to a potential hazard or unsafe practice, which could result in
Thissymbol refers to a potential hazard or unsafe practice, whichmay result in minoror
!
!
!
NOTICE:
eventhough notdangerous.
!
This symbol refers to informationthat needs specialattention or mustbe fully understood
!
2
GENERAL INFORMATION
THIS MANUAL SHOULD BE RETAINED FOR FUTURE REFERENCE
CAUTION:
positioned so the general public can use the equipment make sure that cautions, warnings, and
!
operating instructions are clearly posted near each unit so that anyone using the equipment will useit correctly and not injurethemselves or harm theequipment.
WARNING:
!
andfrequency listedon the data plate. Connect only to 1 or 3phase as listed on thedata plate.
WARNING:
!
nationalelectrical code and/or otherlocal electricalcodes.
These models are designed, built, and sold for commercial use. If these models are
Checkthe data plate on this unitbefore installation.Connect theunit only to the voltage
Electrical and grounding connections must comply with the applicable portions of the
TABLE OF CONTENTS
SECTION ITEM PAGE
........
!
!
!
1 Specifications 4
2 5
3 General Operation Instructions 6
4 General
5 General 6
6 Warranty Procedure 6
7 Wiring Diagram 7
8 Parts List & Exploded View 8
9 Warranty 11
Installation Instructions
Cleaning Instructions 6
Troubleshooting
3
1. SPECIFICATIONS
MODEL VOLTAGE/KW/AMPS
HFW-AT-2 120V - 1.7 KW - 14.2 5-20P 70107000 70107012 55310
HFW-AT-2 208V - 1.7 KW - 8.2 6-15P 70107070 70107072 85640
HFW-AT-2 240V - 1.7 KW - 7.0 6-15P 70107064 70107074 85640
HFW-AT-3 208V - 2.55 KW - 12.3 L6-20P 70107018 70107013 55952
HFW-AT-3 240V - 2.55 KW - 10.6 6-15P 70107065 70107075 85640
N/A 120V N/A N/A N/A N/A
HFW-AT-4 208V - 3.4 KW - 16.3 L6-30P 70107035 70107014 55950
HFW-AT-4 240V - 3.4 KW - 14.2 L6-20P 70107066 70107076 55952
N/A 120V N/A N/A N/A N/A
HFW-AT-5 208V - 4.25 KW - 20.4 L6-30P 70107054 70107015 55950
HFW-AT-5 240V - 4.25 KW - 17.4 L6-30P 70107067 70107077 55950
N/A 120V N/A N/A N/A N/A
HFW-AT-6 208V - 5.1 KW - 24.5 L6-50P 70107028 70107016 55951
HFW-AT-6 240V - 5.1 KW - 21.3 L6-30P 70107068 70107078 55950
N/A 120V N/A N/A N/A N/A
NEMA
CONFIGURATION
HFW
NO DRAIN
HFW-D
WITH DRAIN
CORD ASS’Y
DIMENSIONS: MODELS HFW-AT-2 thru 6
A
B
D
E
ABCDEFG
HFW-AT-2 29.750 12.911 23.438 4.078 1.250 4.383 21.875 HFW-AT-3 44.125 12.911 23.438 4.078 1.250 4.383 21.875 HFW-AT-4 58.500 12.911 23.438 4.078 1.250 4.383 21.875 HFW-AT-5 72.875 12.911 23.438 4.078 1.250 4.383 21.875 HFW-AT-6 87.250 12.911 23.438 4.078 1.250 4.383 21.875
C
F
G
4