CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES
© June 2017
Explosionproof, Dust-Ignitionproof
Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
NEC:
Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Class III NEMA 7CD, 9EFG
Applications
• Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect operation of lighting and light power loads.
• For use in classied areas where ignitable vapors, gases or highly combustible dusts are present.
• For installation in:
— Chemical and petrochemical plants
— Reneries
— Other process industries
Features
• Enclosures have external mounting lugs for ease of mounting.
• Smooth, rounded integral bushing in each hub protects conductor insulation.
• Enclosures furnished with internal ground screw.
• 20 Amp and 30 Amp units available for use with 120-277 Vac.
• Smooth ground mating surfaces assure ame-tight joint
between cover and mounting enclosure.
• Stainless steel hex head cap screws for attaching cover to mounting enclosure.
• Choice of front-operating or side rocker arm handle—each may be locked in ON or OFF position.
• Each handle has close-tolerance threaded stainless steel shaft to meet explosionproof requirements.
• Enclosures furnished with internal ground screw.
Options
• 1- or 2-gang copperfree (4/10 of 1% max.) aluminum bodies and covers available. Add sufx – A.
NPBRKT nameplate mounting bracket to make circuit
description/identication easy.
— Pre-drilled holes in bottom of bracket allow direct mounting
to control stations with existing cover bolts.
— Pre-drilled holes in middle of bracket allow mounting of
customer’s circuit identication nameplate; epoxy glue
may also be used for mounting (phenolic nameplate not included).
— Bracket eliminates costly eld installation of drilling and
tapping to accommodate circuit identication nameplate.
— Brackets t side-by-side on 2-, 3- and 4-gang boxes and
3-devices.
Standard Materials
• Body and cover: malleable iron
• Handle: nylon 6/6
• Optional nameplate mounting bracket: corrosion resistant stainless steel
Standard Finishes
• Tumbler switch body: triple-coat—(1) zinc electroplate, (2) chromate, and (3) epoxy powder coat
NEC Certifications and Compliances
• UL Standards: UL 894, UL 1203
• UL Listed: E10523, E81751
Ordering Information for ”Custom” Units
• Devices, covers and bodies may be ordered separately so that a different EFS switch may be used in each gang.
• Order components separately as follows:
(1) select body catalog number, (2) select cover catalog number, and
Front Operated Rocker Arm Operated
Illustrated Features
Handles may be locked in ON or OFF position
(3) select switch or switch assembly catalog number (1-pole,
2-pole, 3-way or 4-way available in listings).
How to Order Hub Arrangements
• Simply send sketch indicating sizes and locations for brazed hubs on body or bodies selected from catalog listings. Orient sketch so that cover opening faces front and mounting lugs face upward and downward (box wall opposite cover should be referred to as the back of box).
Bodies and Hubs Available
• Tumbler switches may be ordered in single thru ve gang deep malleable iron blank bodies with brazed hubs as specied at
any location.
• Tumbler switches may be ordered with tandem malleable iron
boxes with additional brazed hubs as specied.
• Standard malleable iron single and 2-gang tumbler switches
may be ordered with additional brazed hubs as specied.
• Single and 2-gang tumbler switches may be ordered with
aluminum boxes with additional brazed hubs as specied.
Related Products
• For classied-location push button, pilot light and selector
switch control stations, see EFD/EFDB and EDS Control Stations and Pilot Lights.
78
CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES
© June 2017
Front Operated. Explosionproof, Dust-Ignitionproof
Malleable Iron Body and Cover. Furnished with Internal Ground Screw.
NEC:
Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Class III NEMA 7CD, 9EFG
1-Gang
2-Gang
Dead-End
Feed-Thru
Dead-End
Hub Size (Inches) Switch
20 Amp — 120-277 Vac
1/2 1-Pole EFS150-F1 EFSC150-F1
1/2 2-Pole EFSC150-F2
1/2 3-Way EFS150-F3W EFSC150-F3W
1/2 4-Way EFS150-F4W EFSC150-F4W
3/4 1-Pole EFS175-F1 EFSC175-F1
3/4 2-Pole EFS175-F2 EFSC175-F2
3/4 3-Way EFS175-F3W EFSC175-F3W
3/4 4-Way EFS175-F4W EFSC175-F4W
30 Amp — 120-277 Vac
3/4 1-Pole EFS175-F13 EFSC175-F13
3/4 2-Pole EFS175-F23 EFSC175-F23
20 Amp — 120-277 Vac
1/2 1-Pole EFS250-F1 EFSC250-F1
1/2 2-Pole EFSC250-F2
1/2 3-Way EFSC250-F3W
1/2 4-Way EFSC250-F4W
3/4 1-Pole EFS275-F1 EFSC275-F1
3/4 2-Pole EFSC275-F2
3/4 3-Way EFSC275-F3W
3/4 4-Way EFSC275-F4W
1 2-Pole EFS210-F2 EFSC210-F2
1 3-Way EFS210-F3W EFSC210-F3W
1 4-Way EFS210-F4W EFSC210-F4W
Dead-End Feed-Thru
Catalog Number
30 Amp — 120-277 Vac
Feed-Thru
For aluminum backbox and cover, add suffix -A. 20 Amp — 1 HP at 120 Vac and 2 HP at 240 Vac. 30 Amp — 2 HP at 120 Vac or 240 Vac.
3/4 1-Pole EFS275-F13 EFSC275-F13
3/4 2-Pole EFSC275-F23
1 2-Pole EFS210-F23 EFSC210-F23
79
EFS Non-Sealed Rocker Tumbler Switches
CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES
© June 2017
Arm Operated. Explosionproof, Dust-Ignitionproof
Furnished with Internal Ground Screw.
NEC:
Class I, Division 1 and 2, Groups C, D Class II, Division 1 and 2, Groups E, F, G Class III NEMA 7CD, 9EFG
1-Gang
2-Gang
Dead-End
Feed-Thru
Dead-End
Hub Size (Inches) Switch
20 Amp — 120-277 Vac
1/2 1-Pole EFS150-R1 EFSC150-R1
1/2 2-Pole EFSC150-R2
1/2 3-Way EFS150-R3W EFSC150-R3W
1/2 4-Way EFS150-R4W EFSC150-R4W
3/4 1-Pole EFS175-R1 EFSC175-R1
3/4 2-Pole EFS175-R2 EFSC175-R2
3/4 3-Way EFS175-R3W EFSC175-R3W
3/4 4-Way EFS175-R4W EFSC175-R4W
20 Amp — 120-277 Vac
1/2 1-Pole EFS250-R1 EFSC250-R1
1/2 2-Pole EFSC250-R2
1/2 3-Way EFSC250-R3W
1/2 4-Way EFSC250-R4W
3/4 1-Pole EFS275-R1 EFSC275-R1
3/4 2-Pole EFSC275-R2
3/4 3-Way EFSC275-R3W
3/4 4-Way EFSC275-R4W
1 2-Pole EFS210-R2 EFSC210-R2
1 3-Way EFS210-R3W EFSC210-R3W
1 4-Way EFS210-R4W EFSC210-R4W
Dead-End Feed-Thru
Catalog Number
Feed-Thru
20 Amp — 1 HP at 120 Vac and 2 HP at 240 Vac.
80