ATX™ DB Series IIC Elbows
Increased Safety
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD
Ex d IIC
Applications
• Used to connect two lengths of conduit.
• Used to make 90° bends in conduit runs.
Features
• Accurately tapped, tapered threads for tight, rigid joints and
ground continuity.
Standard Materials
• Aluminum
Features
• Female to female thread.
ATEX/IECEx Certifications and Compliances
• Certication Type ELF
— Gas: Zone 1
– Type of Protection: Ex d IIC Gb; Ex e IIC Gb
— Dust: Zone 21
– Type of Protection: Ex tb IIIC Db
• Conforming to ATEX 94/9/CE: II 2GD
• Operating Temperatures: -55 °C to +150 °C (-67 °F to +302 °F)
• CE Declaration of Conformity: 5C223
• ATEX Certicate: CESI 01 ATEX 104U
• IECEx Certicate: IECEx CES 15.0005U
• Index of Protection according EN/IEC 60529: IP66/67
Tapered Thread
(NPT)
1/2” 73 (2.87) 57 (2.24) 0.12 (0.28) 0.12 (7.32) 500054
3/4” 73 (2.87) 67 (2.64) 0.10 (0.22) 0.12 (7.32) 500055
1” 92 (3.62) 83 (3.27) 0.20 (0.44) 0.23 (14.04) 500056
HAZARDOUS LOCATION FITTINGS: ATEX/IECEx FLAMEPROOF, INCREASED SAFETY CONDUIT FITTINGS
1-1/4” 115 (4.53) 84 (3.31) 0.40 (0.88) 0.50 (30.51) 500057
1-1/2” 115 (4.53) 84 (3.31) 0.60 (1.32) 0.50 (30.51) 500058
3” 185 (7.28) 95 (3.74) 0.50 (1.10) 2.00 (122.03) 500059
Dimensions mm (in)
Weight
kg (lb)
Volume
dm3 (in3)
Catalog
NumberA B
672
© November 2016