With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max.
NEC:
Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 3R, 4, 4X, 9FG
Applications
• Locations where receptacles are used with stationary or
portable electrically operated devices such as:
— Lighting systems
— Conveyors
— Heaters
— Motor-generator sets
— Air conditioners
— Compressors
— Pumps
— Locations where damp or corrosive conditions exist
• Class II: classied locations such as:
— Process industries where there are dust hazards from
handling such products as our, grain and starch or any
location where ignitable amounts of dust are present or
amounts which would adversely affect performance
Features
• Energized receptacle contacts deeply recessed to reduce
danger of accidental touching.
• Style 2 (shell and extra pole) grounding.
• Spring door keeps dust out of receptacle when plug is not in
use. Screw cap also supplied.
• Brass contacts exert constant pressure along entire contact
surface and provide superior electrical contact.
• Contacts have beryllium copper wire springs.
• Plug mechanical cable clamps prevent strain on cables– they
meet or exceed UL strain relief pull-out requirements.
• Neoprene bushing compressed by cable collar prevents
entrance of water.
• Insulators provide superior dielectric and mechanical strength
and lowest arc tracking.
• 1-1/2 NPT tapped conduit openings; one top two bottom.
• Interlocked disconnect switch provides safe connect and
disconnect operation at 30, 60 or 100 Amp, 600 Vac maximum.
Two or three pole, non-fused motor circuit switch.
• Interlocked circuit breaker provides interlocked connect and
disconnect operation as well as short circuit and thermal time
delay overload protection. DBR permits safe operation in Class
II and III only.
• To operate, insert plug (which automatically locks into
receptacle) and turn Breaker Handle to ”ON” position. To
remove plug, turn Handle to ”OFF” position, lift Plug Release
Knob and pull plug out.
• ACP and CPH plug ts Powertite™ Series hazardous location
and DBR receptacles.
Standard Materials
• DBR receptacles: copperfree (4/10 of 1% max.) aluminum
receptacle and mounting box
• CPH and ACP plugs: copperfree (4/10 of 1% max.) aluminum
housings
• For Group B version add sufx -GB to receptacle (Group B
version not suitable for NEMA 4, 4X).
• For GE breaker, add -GE to receptacle. Contact your local
representative for availability and price.
• Molded case switch available on the 150 Amp versions, add
sufx -K to receptacle.
• Special Polarization: Prevents plug insertion in a receptacle or
connector wired for a different voltage. In installations where
there are different line voltages, the special polarization option
is desirable. This allows only plugs and receptacles wired for
the same line voltage to be mated together. The receptacle
or connector interior is positioned 22-1/2°, relative to the
polarization rivet, to the right (as specied) of standard, and
plug is polarized to correspond. This option can be added
to receptacles using the Powertite™ Plug. Add sufx -P4 to
receptacle or plug.
• For 2” feed-thru openings (one top, one bottom) add sufx -22
to receptacle.
• UL Standard: UL 1010 (UL 1203), UL 894, UL 1682, UL 1686
Plugs and RecePtacles: nec/cec HazaRdous location
• Flip cover suitable for NEMA 3, 3R only.
NEMA 4 rating maintained with Appleton NEMA 4 plug installed. Install screw cover for 4, 4X. Both covers are included with product.
Add suffix -GB to Cat. No. for Group B. (Group B version not suitable for NEMA 4, 4X).
GE is a registered trademark of General Electric Company.
441
DBR 30, 60 and 100 Amp Series Receptacles
Dust-Ignitionproof
With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max.
NEC:
Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 3R, 4, 4X, 9FG
DBR Receptacles with Disconnect Switch
ReceptacleWires/PolesCatalog Number
30 Amp
60 Amp
100 Amp
DBR with Switch
DBR Receptacles with Circuit Breaker
DBR with Breaker
Plugs and RecePtacles: nec/cec HazaRdous location
Receptacle
30 Amp
2W, 3P
30 Amp
3W, 4P
60 Amp
2W, 3P
60 Amp
3W, 4P
100 Amp
2W, 3P
100 Amp
3W, 4P
Circuit
Breaker AmpPole
202DBR3023EH20DBR3023FB20DBR3023HFB20
302DBR3023EH30DBR3023FB30DBR3023HFB30
402DBR3023EH40DBR3023FB40DBR3023HFB40
502DBR3023EH50DBR3023FB50DBR3023HFB50
203DBR3034EH20DBR3034FB20DBR3034HFB20
303DBR3034EH30DBR3034FB30DBR3034HFB30
403DBR3034EH40DBR3034FB40DBR3034HFB40
503DBR3034EH50DBR3034FB50DBR3034HFB50
502DBR6023EH50DBR6023FB50DBR6023HFB50
602DBR6023EH60DBR6023FB60DBR6023HFB60
702DBR6023EH70DBR6023FB70DBR6023HFB70
902DBR6023EH90DBR6023FB90DBR6023HFB90
1002DBR6023EH100DBR6023FB100DBR6023HFB100
503DBR6034EH50DBR6034FB50DBR6034HFB50
603DBR6034EH60DBR6034FB60DBR6034HFB60
703DBR6034EH70DBR6034FB70DBR6034HFB70
903DBR6034EH90DBR6034FB90DBR6034HFB90
1003DBR6034EH100DBR6034FB100DBR6034HFB100
502DBR1023EH50DBR1023FB50DBR1023HFB50
702DBR1023EH70DBR1023FB70DBR1023HFB70
902DBR1023EH90DBR1023FB90DBR1023HFB90
1002DBR1023EH100DBR1023FB100DBR1023HFB100
503DBR1034EH50DBR1034FB50DBR1034HFB50
703DBR1034EH70DBR1034FB70DBR1034HFB70
903DBR1034EH90DBR1034FB90DBR1034HFB90
1003DBR1034EH100DBR1034FB100DBR1034HFB100
2W, 3PDBR3023DS
3W, 4PDBR3034DS
2W, 3PDBR6023DS
3W, 4PDBR6034DS
2W, 3PDBR1023DS
3W, 4PDBR1034DS
Catalog Number
with 480 Vac
EHD Breaker
with 600 Vac
FDB Breaker
with 600 Vac
FD Breaker
Circuit Breakers are Cutler-Hammer. Cutler-Hammer F-Frame breakers available up to 175 Amps. Add GE after EH, FB, or HFB for GE Circuit Breakers.
Contact your local representative for availability and price. Cutler-Hammer is a registered trademark of Eaton Corporation. GE is a registered trademark of
General Electric Company.
NEMA 4 rating maintained with Appleton NEMA 4 plug installed. Install screw cover for 4, 4X. Both covers are included with product.
442
DBR Receptacles 30, 60, 100 and 150 Amp
Circuit Breaker and Disconnect Switch Data
600 Vac Max.
NEC:
Class II, Division 1 and 2, Groups F, G
Class III
NEMA 3, 3R, 4, 4X, 9FG
DBR Horsepower Tables
These Cutler-Hammer circuit breaker recommendations are for induction motors running with usual speed and torque characteristics. Ambient temperature, and
frequency of starting could require different protective characteristics.