Stainless Steel Ball Valve with Mounting Pad 1/4” - 1”
Female NPT Thread, 2000 CWP (psig). Cold Non-Shock. (See referenced P/T chart)
150 psig Saturated Steam.
Vacuum Service to 29 inches Hg.
MSS SP-110 compliant.
FEATURES
• Investment cast components
• Reinforced seats
• Mounting pad for easy actuator mounting
• Blow-out-proof stem design
• Adjustable packing gland
• Stainless Steel lever and nut
• Fire safe to API 607 (requires -24 sux)
• Meets NACE MR0175 (2000) & MR0103 (2012)
• CSA CGA 3.16-M88 (Requires “GS” sux)
• NSF/ANSI 61 Section 8, Annex G
• NSF-372, Drinking Water System Components - Lead Content
OPTIONS AVAILABLE: (More information in Section J)
• Minimum quantities apply
• To specify an option, replace the “01” standard sux with the sux of the option.
• To specify multiple options, replace the “01” sux with the desired suxes in the
numerical order shown below. NOTE: Not all suxes can be combined together.
SUFFIXOPTIONSIZES
-01Standard CongurationAll
-P -01-BSPP (Parallel) Thread Connection1/4” to 3”
-T -01-BSPT (Tapered) Thread Connection1/4” to 3”
-02-Stem Grounded
-04-
-07-Steel Tee Handle1/4” to 2”
-08-90º Reversed Stem1/4” to 3”
-14-Side Vented Ball (Uni-Directional)1/4” to 2”
-15-Wheel Handle, Steel1/4” to 2”
-16-Chain Lever - Vertical 3/4” to 2”
-19-Lock Plate1/4” to 2”
-21-UHMWPE Trim (Non-PTFE)1/4” to 3”
-24-
-27-SS Latch-Lock Lever & Nut1/4” to 3”
-30-Cam-Lock and Grounded1/4” to 2”
-32-SS Tee Handle & Nut1/4” to 2”
STANDARD MATERIAL LIST
PARTMATERIAL
1Lever and grip304 SS w/vinyl
2Stem packingMPTFE
3Stem bearingRPTFE
4BallA276-316 Stainless Steel
5Seat (2)RPTFE
6RetainerA351-CF8M SS or A276-316 SS
7Gland nutA276-316 Stainless Steel
8StemA276-316 Stainless Steel
9Lever nut18-8 Stainless Steel
10Body sealPTFE
11Body A351-CF8M Stainless Steel
* LEAD FREE: The wetted surfaces of this product shall contain no more than
0.25% lead by weighted average. Complies with Federal Public Law
111-380. ANSI 3rd party approved and listed.
www.apollovalves.com Customer Service (704) 841-6000
-35-PTFE Trim1/4” to 3”
-39-SS Hi-Rise Locking Wheel Handle, SS Nut1/4” to 2”
-40-Cyl-Loc and Grounded1/4” to 2”
-44-Seal Welded1/4” to 2”
-45-Less Lever & Nut1/4” to 3”
-46-Latch Lock Lever - Lock in Closed Position Only1/4” to 3”
-47-SS Latch Lock Oval Handle1/4” to 2”
-48-SS Oval Handle (No Latch) & Nut1/4” to 2”
-49-No Lubrication. Assembled Dry.1/4” to 3”
-50-2.25” CS Locking Stem Extension1/4” to 3”
-57-Oxygen Cleaned1/4” to 3”
-58-Chain Lever - Horizontal3/4” to 2”
-60-Static Grounded Ball & Stem1/4” to 3”
-64-250# Steam Trim (MPTFE Seats & Packing)1/4” to 3”
-GSCSA CGA 3.16All
FOR PRESSURE/TEMPERATURE RATINGS, REFER TO PAGE M14, GRAPH NO. 14
2.25” Stem Extension (Carbon Steel, Zinc Plated)
Graphite packing, PTFE body seal, RPTFE bearing
(Fire Safe API 607, 6th edition, ISO 10497:2010)
1/4” to 3”
1/4” to 3”
1/4” to 3”
76100 SERIES
Stainless Steel Ball Valve with Mounting Pad 1.25” - 2”
Female NPT Thread, 1500 CWP (psig). Cold Non-Shock. (See referenced P/T chart)
150 psig Saturated Steam.
Vacuum Service to 29 inches Hg.
MSS SP-110 compliant.
FEATURES
• Investment cast components
• Reinforced seats
• Mounting pad for easy actuator mounting
• Blow-out-proof stem design
• Adjustable packing gland
• Stainless Steel lever and nut
• Fire safe to API 607 (requires -24 sux)
• Meets NACE MR0175 (2000) & MR0103 (2012)
• CSA CGA 3.16-M88 (Requires “GS” sux)
• NSF/ANSI 61 Section 8, Annex G
• NSF-372, Drinking Water System Components - Lead Content
OPTIONS AVAILABLE: (More information in Section J)
• Minimum quantities apply
• To specify an option, replace the “01” standard sux with the sux of the option.
• To specify multiple options, replace the “01” sux with the desired suxes in the
numerical order shown below. NOTE: Not all suxes can be combined together.
SUFFIXOPTIONSIZES
-01Standard CongurationAll
-P -01-BSPP (Parallel) Thread Connection1/4” to 3”
• NSF-372, Drinking Water System Components - Lead Content
OPTIONS AVAILABLE: (More information in Section J)
• Minimum quantities apply
• To specify an option, replace the “01” standard sux with the sux of the option.
• To specify multiple options, replace the “01” sux with the desired suxes in the
numerical order shown below. NOTE: Not all suxes can be combined together.
SUFFIXOPTIONSIZES
-01Standard CongurationAll
-02-Stem Grounded
-04-
-07-Steel Tee Handle1/4” to 2”
-08-90º Reversed Stem1/4” to 3”
-14-Side Vented Ball (Uni-Directional)1/4” to 2”
-15-Wheel Handle, Steel1/4” to 2”
-16-Chain Lever - Vertical 3/4” to 2”
-19-Lock Plate1/4” to 2”
-21-UHMWPE Trim (Non-PTFE)1/4” to 3”
-24-
-27-SS Latch-Lock Lever & Nut1/4” to 3”
-30-Cam-Lock and Grounded1/4” to 2”
-32-SS Tee Handle & Nut1/4” to 2”
-35-PTFE Trim1/4” to 3”
-39-SS Hi-Rise Locking Wheel Handle, SS Nut1/4” to 2”
-40-Cyl-Loc and Grounded1/4” to 2”
-44-Seal Welded1/4” to 2”
-45-Less Lever & Nut1/4” to 3”
-46-Latch Lock Lever - Lock in Closed Position Only1/4” to 3”
-47-SS Latch Lock Oval Handle1/4” to 2”
-48-SS Oval Handle (No Latch) & Nut1/4” to 2”
-49-No Lubrication. Assembled Dry.1/4” to 3”
-50-2.25” CS Locking Stem Extension1/4” to 3”
-57-Oxygen Cleaned1/4” to 3”
-58-Chain Lever - Horizontal3/4” to 2”
-60-Static Grounded Ball & Stem1/4” to 3”
-64-250# Steam Trim (MPTFE Seats & Packing)1/4” to 3”
-GSCSA CGA 3.16All
* LEAD FREE: The wetted surfaces of this product shall contain no more than 0.25%
lead by weighted average. Complies with Federal Public Law 111-380. ANSI 3rd party
approved and listed.
2.25” Stem Extension (Carbon Steel, Zinc Plated)
Graphite packing, PTFE body seal, RPTFE bearing
(Fire Safe API 607, 6th edition, ISO 10497:2010)
1/4” to 3”
1/4” to 3”
1/4” to 3”
FOR PRESSURE/TEMPERATURE RATINGS, REFER TO PAGE M12, GRAPH NO. 8
www.apollovalves.com Customer Service (704) 841-6000
FLOW DATA
For Apollo® Ball Valves
The listed Cv “factors” are derived from actual ow testing, in the Apollo® Ball Valve Division, Conbraco Industries, Inc., Pageland, South Carolina.
These tests were completed using standard “o the shelf” valves with no special preparation and utilizing standard schedule 40 pipe. It should
be understood that these factors are for the valve only and also include the connection conguration. The ow testing is done utilizing water
as a uid media and is a direct statement of the gallons of water owed per minute with a 1 psig pressure dierential across the valve/
connection unit. Line pressure is not a factor. Because the Cv is a factor, the formula can be used to estimate ow of most media for valve sizing.
FLOW OF LIQUID
Q = C
or ∆P =
Where:
Q = ow in US gpm
ΔP = pressure drop (psig)
SpGr = specic gravity at owing temperature
Cv = valve constant
Q = ow in SCFH
ΔP = pressure drop (psig)
SpGr = specic gravity (based on air = 1.0)
P2 = outlet pressure–psia (psig + 14.7)
T = (temp. °F + 460)
Cv = valve constant
CAUTION: The gas equation shown, is valid at very low pressure drop ratios.
The gas equation is NOT valid when the ratio of pressure drop (ΔP) to inlet
pressure (P1) exceeds 0.02.
NOTE: Only use the gas equation shown if (P1-P2)/P1 is less than 0.02.