APG PT-L9, PT-L13 Specifications

APG
Millivolt-per-Volt Output Pressure Transducer Series: PT-L9/L13/L14
®
fective, high reliability unit is required. The PT-L9/L13/L14 pressure transducers oer ranges from vacuum to 10,000
psi, single piece stainless steel construction, and a tamper-resistant body design.
Features
Cost eective
Optional extended temperature compensation
Stainless steel process tting and sensor
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
Rev. B, 07/12/2019
APG
PT-L9/L13/L14 Specications
1/4-18 NPT3/4" HEX
3.018" MAX
[76.66mm]
.75"
[19.1mm]
2.60" MAX
[58.4mm]
.25"
[6.3mm]
.72"
[18.3mm]
1/4-18 NPT3/4" HEX
LENGTH
PER ORDER
.75"
[19.1mm]
2.30" MAX
[58.4mm]
.25"
[6.3mm]
.72"
[18.3mm]
Performance
• Accuracy
B.F.S.L. ≤ 0.25% of full scale NIST up to ±0.1% available on select ranges
• Temp Compensation Range: (Standard)
Up to 0º - 130ºF (-17º - 54ºC)
• Extended Temp Compensation Range: (Optional)
Up to -40º - 250ºF (-40º - 121ºC)
Connectivity
• Output:
L9: 10 mV/V ±2% L13: 3 mV/V ±2% L14: 5 mV/V ±2%
Electrical
• Supply Voltage: All Models calibrated for 10VDC input
• Electrical Protection:
Reverse polarity
Physical
• Material: 15-5, 17-4, or 316L SS
Programming
• Field Calibration:
No eld adjustments available
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
®