APG PT-L1, PT-L3, PT-L10 Operating Manual

APG
PT-L Pressure Transducer
User Manual
Amplied Output Series
R
Doc #9004131
Rev A3, 01/18
Table of Contents
Introduction ................................................................................................................ iii
Warranty and Warranty Restrictions .................................................................... iv
Chapter 1: Specications and Options.....................................................................1
Dimensions ........................................................................................................................................1
Specications ...................................................................................................................................2
Model Number Congurator .......................................................................................................... 3
Electrical Connectors, Pinout Table, and Supply Power Table .............................................. 4
Wiring Diagrams .............................................................................................................................. 5
Chapter 2: Installation and Removal Procedures and Notes ..............................5
Tools Needed .....................................................................................................................................5
Mounting Instructions ................................................................................................................... 6
Electrical Installation .....................................................................................................................6
Removal Instructions .....................................................................................................................6
Chapter 3: Maintenance .............................................................................................7
General Care ...................................................................................................................................... 7
Zero Trimming ...............................................................................................................................7-8
Re-Calibration ................................................................................................................................... 8
Repair and Returns .......................................................................................................................... 8
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Introduction
Thank you for purchasing a PT-L amplied series pressure transmitter from APG. We appreciate your business! Please take a few minutes to familiarize yourself with your PT-L and this manual.
The PT-L series of pressure transmitters oers economical reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature range, and durability, make the PT-L the perfect instrument with an amplied output signal for static and dynamic pressure measurements.
Reading your label
Every APG instrument comes with a label that includes the instrument’s model number, part number, serial number, and a wiring pinout table. Please ensure that the part number and pinout table on your label match your order.
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
iii
Warranty and Warranty Restrictions
This product is covered by APG’s waranty to be free from defects in material and workmanship under normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit
https://www.apgsensors.com/about-us/terms-conditions. Contact Technical Support to recieve a Return
Material Authorization before shipping your product back.
Scan the QR code below to read the full explanation of our Warranty on your tablet or smartphone.
iv
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Chapter 1: Specications and Options
• Dimensions
3.90
[99.1]
.25
[6.4]
.55
[14.0]
LOC-TITE®
Automation Products Group
Model #:
Part #: Range:
1025 West 1700 North
Logan, UT 84321 USA Phone (888) 525-7300
3/4" HEX
1/4" NPT
K0, E3 - KNURLED NUT, 4-PIN BAYONET
4-PIN BAYONET w/ KNURLED NUT
CAN - PROCESS CONNECTION w/ LOC-TITE®
3.54
[89.9]
.25
[6.4]
.55
[14.0]
WELDED CONNECTION
Automation Products Group
Model #:
Part #: Range:
1025 West 1700 North
Logan, UT 84321 USA Phone (888) 525-7300
.75
[19.1]
LENGTH PER ORDER
.75
[19.1]
3.92
[99.6]
.25
[6.4]
.55
[14.0]
LOC-TITE®
Automation Products Group
Model #:
Part #: Range:
1025 West 1700 North
Logan, UT 84321 USA
Phone (888) 525-7300
3/4" HEX
1/4" NPT
K1, E4 - TAMPER RESISTANT NUT, 4-PIN M12
EUROFAST M12 w/ TAMPER RESISTANT NUT & LOC-TITE®
CAN - PROCESS CONNECTION w/ LOC-TITE®
3.97
[100.8]
.25
[6.4]
.55
[14.0]
WELDED CONNECTION
Automation Products Group
Model #:
Part #: Range:
1025 West 1700 North
Logan, UT 84321 USA
Phone (888) 525-7300
.75
[19.1]
M12x1
TAMPER RESISTANT w/ LOC-TITE®
.75
[19.1]
3/4" HEX
1/4" NPT
TAMPER RESISTANT w/ LOC-TITE®
K2, E5 - TAMPER RESISTANT NUT, PIGTAIL
CABLE PIGTAIL W/ TAMPER RESISTANT NUT & LOC-TITE®
CAN - PROCESS CONNECTION WELDED
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
3/4" HEX
1/4" NPT
K3, E3 - WELDED 4-PIN BAYONET
4-PIN BAYONET, WELDED CONNECTION
CAN - PROCESS CONNECTION WELDED
WELDED CONNECTION
1
Loading...
+ 9 hidden pages