APG NLS Pneumatic User Manual

NLS Pneumatic Level Sensor
APG
Flexible by Design
The NLS pneumatic liquid level sensor is designed for use in high viscosity liquids. It is modied to
overcome the high viscosity by making the tip of the detecting pipe larger than usual. The NLS is the ideal sensor for applications where electrical power is not available or hazardous conditions exist. Using a diaphragm, the switch is actuated by compression of a captive air column in the detecting pipe beneath the diaphragm.
Features
Simple installation
Rugged and reliable
Long switch life
Automation Products Group, Inc. www.apgsensors.com
tel. 888.525.7300 sales@apgsensors.com
NLS Specications
APG
NLS-1A NLS-1S NLS-3
Performance
• SPDT switch
• Detection Range: 8 - 200 in (200 - 5,000 mm)
Connectivity
• Output Contact Rating: 250 V 10 A AC; 115 V 0.5 A DC (resistive)
Certication
• NEMA 4, IP42
• NEMA 1, IP20 (NLS-3)
Water
Oil
Wastewater
Chemicals
Solvents
Options
Physical
• Housing: ADC12 SS41 (NLS-3)
• Diaphragm: Neoprene®, Viton
Environmental
• Operating Temperature:
-4º - 158ºF (-20º - 70ºC)
NLS-1A NLS-1S NLS-3
®
Part Number: NLS - _____
A
A. Protective Bellows
1A Standard materials (Neoprene1S Corrosive materials (Viton3 Indoor, light duty (Neoprene
®
)
®
)
®
)
Automation Products Group, Inc. www.apgsensors.com
tel. 888.525.7300 sales@apgsensors.com 2