APG MPI-F Operating Manual

APG
MPI Magnetostrictive Level Sensors
User Manual
Flexible Stem, Intrinsically Safe Probe
Doc #9005623
R
Part #200337
Rev A, 12/2019
Table of Contents
Introduction ................................................................................................................ iii
Warranty and Warranty Restrictions .................................................................... iv
Chapter 1: Specications and Options.....................................................................1
Dimensions ....................................................................................................................................1-2
Specications ...................................................................................................................................3
Model Number Congurator .......................................................................................................... 4
System Wiring Diagrams and IS Use Case Diagrams .......................................................... 5-6
Chapter 2: Installation and Removal Procedures and Notes ..............................7
Tools Needed .....................................................................................................................................7
ATEX Stated Conditions of Use .....................................................................................................7
Physical Installation Notes ...........................................................................................................7
Physical Installation Instructions ............................................................................................... 8
Electrical Installation .....................................................................................................................9
Removal Instructions .....................................................................................................................9
Chapter 3: Programming ..........................................................................................10
Modbus Programming .................................................................................................................. 10
Modbus Programming with RST-6001 and APG Modbus Software .................................... 10
Modbus Register Lists for MPI-F .......................................................................................... 10-11
MPI-F Modbus Sensor Parameters ....................................................................................... 12-16
MPI-F Modbus Application Type Parameters .................................................................... 17-21
Chapter 4: Maintenance ...........................................................................................22
General Care .................................................................................................................................... 22
Repair and Returns ........................................................................................................................22
Chapter 5: Hazardous Location Installation and Certication .........................23
Intrinsically Safe Installation Drawing for Hazardous Locations ......................................23
CSA Certicate of Compliance .............................................................................................. 24-26
IECEx Certicate of Conformity ...........................................................................................27-29
EU Declaration of Conformity .....................................................................................................30
ii
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Introduction
237484
Thank you for purchasing an MPI series magnetostrictive level sensor from APG. We appreciate your business and your trust. Please take a few minutes to familiarize yourself with your MPI and this manual.
The MPI level sensors provide highly accurate and repeatable level readings in a wide variety of liquid level
measurement applications. The MPI-F is certied intrinsically safe for installation in hazardous areas by CSA, ATEX, and IECEx for Class I, Division 1 and Class I, Zones 0 environments. The MPI-F’s exible stainless
steel stem allows for easier installation in extra tall tanks.
Reading your label
Every APG instrument comes with a label that includes the instrument’s model number, part number, and serial number. Please ensure that the part number on your label matches your order. The following
electrical ratings and approvals are also listed on the label. Please refer to the CSA Certicate of Compliance
at the back of this manual for further details.
8-24 VDC, Imax = 280 mA
Class I, Division 1, Groups C, D, T4; IP65 Class I, Zone 0, Ex/AEX ia, IIB, T4, Ga Ex ia IIB, T4 ,Ga (Ta = -40°C to 85°C)
C
US
Intrinsically Safe Wiring Requirements: U
ATEX Certicate Number: Sira 19ATEX2072X
II 1G Ex ia IIB T4 Ga Ta: -40°C to 85°C
U
IECEx SIR 19.0026X
Ex ia IIB T4 Ga Ta: -40°C to 85°C
= 28 V, Ii = 280 mA, Pi = 0.850 W, L
i
= 28 VDC, Ii = 280 mA, Pi = 0.850 W , Li = 3.50 μH, Ci = 0.374 μF
i
= 3.50 μH, Ci = 0.374 μF
i
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
iii
IMPORTANT: MPI-F level sensor MUST be installed according to drawing 9009451
(Intrinsically Safe Installation Drawing for Hazardous Locations) on page 23 to meet listed approvals. Faulty installation will invalidate all safety approvals and ratings.
DANGER: OPEN CIRCUIT BEFORE REMOVING COVER or KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE;
AVERTISSEMENT -- COUPER LE COURANT AVANT D’ENLEVER LE COUVERCLE, ou GARDER LE COUVERCLE FERME TANT QUE LES CIRCUITS SONT SOUS TENSION.
DANGER: WARNING -- EXPLOSION HAZARD -- SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY
FOR CLASS I, DIVISION 2; AVERTISSEMENT -- RISQUE D’EXPLOSION -- LA SUBSTITIOND E COMPOSANTSP EUTR ENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I, DIVISION 2.
DANGER: WARNING -- EXPLOSION HAZARD -- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS
BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS; AVERTISSEMENT -- RISQUE D’EXPLOSION -- AVANT DE DECONNECTER L’EQUIPEMENT, COUPER LE COURANT OU S’ASSURER QUE L’EMPLACEMENT EST DESIGNE NON DANGEREUX.
Warranty and Warranty Restrictions
This product is covered by APG’s warranty to be free from defects in material and workmanship under normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit
https://www.apgsensors.com/about-us/terms-conditions. Contact Technical Support to receive a Return
Material Authorization before shipping your product back.
Scan the QR code below to read the full explanation of our Warranty on your tablet or smartphone.
iv
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Chapter 1: Specications and Options
• Dimensions
MPI-F Sensor Dimensions
CONDUIT
OPENING
HOUSING
[110mm]
4.34"
[145mm]
5.71"
[126mm]
3/4" NPT
4.98"
[110mm]
4.34"
HOUSING
ADAPTER
[125mm]
[48mm]
[254mm]
10.0"
MEASURABLE LENGTH (PER ORDER)
[173.8mm - 177.0mm]
4.94"
1.90"
6.84" - 6.97"
2x Ø2.76"
THRU
GROUND
SCREW
TOP DEADBAND
MOUNTING OPTION FLOAT(S)
TOTAL LENGTH
Housing Connection
Location
MPI-F STEM
ASSEMBLY
FLOAT
STOP
BOT DEADBAND
[152mm]
6.0"
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
1
MPI-F Floats
Float Options
I & J U & V
5.88”4.98”
W & X
5.00”
U & V / I & J
3.03”
3.00”
Float Ref. S1=12.25” S2=4.25”
5.10”
Float Ref. S1=10.63” S2=6”
U & V I & J
S & T
2.80”
3.07”
Y & Z / L & M
5.50”
3.08”
2.00”
Float Ref. S1=12.25” S2=4.25”
Float Ref. S1=10” S2=6.5”
Y & Z L & M
2
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Specications
Performance
Resolution 0.04 in. (1 mm) Accuracy ±0.05% of Full Scale or 1mm (whichever is larger)
Environmental
Operating Temperature -40° to 185° F (-40° to 85° C)
Enclosure Protection NEMA 4X, IP65
Electrical
Supply Voltage 8-24 VDC on sensor Typical Current Draw 25 mA Protection Reverse Polarity and Surge (per IEC 61000-4-5, 4-6, 4-7)
Materials of Construction
Housing Cast aluminum, epoxy coated
Stem 7/8” ø 316L SS Flexible Tubing with Braid Mounting (slide) 316L SS
Compression Fitting (slide) Aluminum with Neoprene bushing
Connectivity
Output Modbus RTU (RS-485)
Programming
RS-485 Optional RST-6001 USB-to-RS-485 converter
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
3
Model Number Congurator
Model Number: MPI - _F_ __5__ _____ - _____ _____ - _____ _____ _____ __B__ - _____ - _____ - _____ A B C D E F G H I J K L
A. Stem Type
F 7/8 in. diameter Flexible Tubing with Braid, 316L SS
B. Output
5 Modbus RTU, with surge protection, Intrinsically Safe
C. Housing Type
All Housing Die-cast Aluminum, NEMA 4X, IP68, Blue
__
Large Housing
B Large Housing with window
D. Float 1 (Top Float)
Z 5.5h x 3d in. Red Polyurethane (0.65 SG) Y 5.5h x 3d in. Blue Polyurethane (0.94 SG) X 5 in. Round 316L SS (0.52 SG) W 5 in. Round 316L SS (0.92 SG) V 6h x 3d in. Oval 316L SS (0.58 SG) U 6h x 3d in. Oval 316L SS (0.94 SG) T 3 in. Round 316L SS (0.60 SG) S 3 in. Round 316L SS (0.94 SG) M 5.5h x 2d in. Red Polyurethane (0.57 SG) L 5.5h x 2d in. Blue Polyurethane (0.94 SG) J 5h x 3d in. Oval Titanium 2 (0.60 SG) I 5h x 3d in. Oval Titanium 2 (0.92 SG) N None
E. Float 2 (optional)
N None Y 5.5h x 3d in. Blue Polyurethane (0.94 SG) W 5 in. Round 316L SS (0.92 SG) U 6h x 3d in. Oval 316L SS (0.94 SG) L 5.5h x 2d in. Blue Polyurethane (0.94 SG) I 5h x 3d in. Oval Titanium 2 (0.92 SG)
F. Mounting Type
F Flat Face ANSI Flange 150#
(Sizes: 2, 2.5, 3, 4, 5, 6)
R Raised Face ANSI Flange 150#
(Sizes: 2, 2.5, 3, 4, 5, 6)
S Tri Clamp
(Sizes: 2, 2.5, 3)
P NPT Plug 150#
(Sizes: 2, 2.5, 3, 4)
N None
G. Mounting Size
__ See Mounting Type for available sizes
H. Mounting Connection
W Welded (xed) S Slide with Compression Fitting (adjustable)
I. Stem Material
B 316L SS
J. Total Stem Length in Inches
__ Min. 120 in. - Max. 300 in.
K. Temperature Sensor Options
N None
1D
Digital Temperature Sensor A, 12 in. from bottom of
probe
2D Digital Temperature Sensors A, B 3D Digital Temperature Sensors A, B, C 4D Digital Temperature Sensors A, B, C, D 5D Digital Temperature Sensors A, B, C, D, E 6D Digital Temperature Sensors A, B, C, D, E, F 7D Digital Temperature Sensors A, B, C, D, E, F, G
Note: Temperature sensors B - G are spaced evenly between
A and probe’s zero reference, with minimum of 2 in. required between temperature sensors.
L. Housing Connection
N
None
A 3/4” to 1/2” NPT Reducing Threads B Cable Gland (Cable sold separately) M 4-pin M12 Micro Connector Male F 4-pin M12 Micro Connector Female
Note: ▲This option is standard.
4
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
System Wiring Diagrams and IS Use Case Diagrams
Modbus System Wiring For MPI-F Sensors
Power Supply
Master
Device
120 Ω terminating resistor may be necessary for long
+8-24 Vdc
GND
RS-485 A (TX+)
RS-485 B (TX-)
Use Shielded Cable
See Hazardous Installation
Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.
See Hazardous Installation Drawing for Intrinsically Safe
installation requirements. Otherwise, wire directly.
cable runs.
Note: When connecting MPI sensors to your system, reversing A and B connections may be necessary if sensors do not communicate with Modbus Master device.
MPI Sensor MPI Sensor MPI Sensor
Sensor 1
V+
B (TX-)
A (TX+)
GND
Sensor 2
V+
B (TX-)
A (TX+)
GND
Modbus System Wiring with RST-6001 For MPI-F Sensors
Power Supply
+8-24 Vdc
GND
Use Shielded Cable
Wiring T’s must be located on controller/supply side of IS barriers.
See Hazardous Installation Drawing for Intrinsically Safe
installation requirements. Otherwise, wire directly.
Sensor 3
V+
B (TX-)
A (TX+)
GND
120 Ω terminating resistor across A & B
terminals of last or only sensor, if necessary.
For installations without IS barriers only.
Wiring T’s must be located on controller/supply side of IS barriers.
RST-6001
Modbus
Controller
USB to computer with APG Modbus software
Note: An independent +8-24 Vdc power supply is required when using an RST-6001 Modbus Controller. The RST-6001 can only supply ±5 Vdc, not the +8-24 Vdc required by the MPI.
IMPORTANT: Refer to Chapter 5 for Intrinsically Safe Installation Drawing for Hazard-
ous Locations.
A B
-5V
+5V
Equivalent 120 Ω
terminating resistor internal to RST-6001
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
See Hazardous Installation Drawing for Intrinsically Safe
installation requirements. Otherwise, wire directly.
MPI sensor
Sensor 1
V+
B A
GND
See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.
MPI sensor MPI sensor
Sensor 2
V+
B A
GND
See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.
Sensor 3
V+
B A
GND
120 Ω terminating resistor across A & B
terminals of last or only sensor, if necessary.
For installations without IS barriers only.
5
MPI - MDI Use Case Diagram
Hazardous Area
Zone 1
MDI Modbus Address: Master Controling: Sensor 1
Zone 0 or Zone 1
MPI Sensor Modbus Address: 1
Single MDI controlling a single MPI sensor
MDI is located in Zone 1 area. MPI can be in Zone 0 or Zone 1 without additional barriers.
MDI is battery powered; allows for software-based switchable power for MPI.
MPI is powered by MDI battery.
No external controller.
No IS barrier required.
Any changes to MPI settings done via MDI buttons.
MPI - MDI with Passive Controller Use Case Diagram
Hazardous AreaNon-hazardous Area
Zone 1
MDI Modbus Address: Master Controling: Sensor 1
Zone 0 or Zone 1
Passive Control Equipment
Modbus: Sniffer
Approved IS Barrier
Sniffing: MDI
Single MDI controlling a single MPI sensor with Passive Control Equipment
MDI is located in Zone 1 area. MPI can be in Zone 0 or Zone 1 without additional barriers.
MDI is battery powered; allows for software-based switchable power for sensor.
MPI is powered by MDI battery.
External controller passively reads (Snis) readings from MDI.
External controller can activate MDI.
Approved IS Barrier required between Passive Control Equipment and MDI.
Auxiliary connection required for MDI.
Any changes to MPI settings done via MDI buttons.
MPI Sensor Modbus Address: 1
6
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Chapter 2: Installation and Removal Procedures and Notes
• Tools Needed
You will need the following tools to install your MPI level sensor:
Wrench sized appropriately for MPI mounting
Wrench sized appropriately for conduit connections
Flat-head screwdriver for wire terminals
Channel lock pliers for tightening compression tting
1/8” Hex Allen wrench for screws on oat stop(s).
Pliers for bending cotter pin.
ATEX Stated Conditions of Use
• Under certain extreme circumstances, the non-metalic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore the equipment shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. In addition, the equipment shall only be cleaned with a damp cloth.
• The enclosure is manufactured from Aluminum. In rare cases, ignition sources due to impact and friction sparks could occur. This shall be considered during installation.
• Physical Installation Notes
The MPI-F should be installed in an area--indoors or outdoors--which meets the following conditions:
Ambient temperature between -40°C and 85°C (-40°F to +185°F)
Relative humidity up to 100%
Altitude up to 2000 meters (6560 feet)
IEC-664-1 Conductive Pollution Degree 1 or 2
IEC 61010-1 Measurement Category II
No chemicals corrosive to stainless steel (such as NH3, SO2, Cl2)
Ample space for maintenance and inspection
Additional care must be taken to ensure:
The probe is located away from strong magnetic elds, such as those produced by motors, transform- ers, solenoid valves, etc.
The medium is free from metallic substances and other foreign matter.
The probe is not exposed to excessive vibration.
The oat(s) t through the mounting hole. If the oat(s) does/do not t, it/they must be mounted on
the stem from inside the vessel being monitored.
The oat(s) is/are oriented properly on the stem (See Figure 2.1). MPI-F oats are installed by customer.
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
7
Loading...
+ 25 hidden pages