Thank you for purchasing an MPI series magnetostrictive level sensor from APG. We appreciate your
business and your trust. Please take a few minutes to familiarize yourself with your MPI and this manual.
The MPI level sensors provide highly accurate and repeatable level readings in a wide variety of liquid level
measurement applications. The MPI-F is certied intrinsically safe for installation in hazardous areas by
CSA, ATEX, and IECEx for Class I, Division 1 and Class I, Zones 0 environments. The MPI-F’s exible stainless
steel stem allows for easier installation in extra tall tanks.
Reading your label
Every APG instrument comes with a label that includes the instrument’s model number, part number,
and serial number. Please ensure that the part number on your label matches your order. The following
electrical ratings and approvals are also listed on the label. Please refer to the CSA Certicate of Compliance
at the back of this manual for further details.
8-24 VDC, Imax = 280 mA
Class I, Division 1, Groups C, D, T4; IP65
Class I, Zone 0, Ex/AEX ia, IIB, T4, Ga
Ex ia IIB, T4 ,Ga
(Ta = -40°C to 85°C)
C
US
Intrinsically Safe Wiring Requirements:
U
ATEX Certicate Number: Sira 19ATEX2072X
II 1G
Ex ia IIB T4 Ga
Ta: -40°C to 85°C
U
IECEx SIR 19.0026X
Ex ia IIB T4 Ga
Ta: -40°C to 85°C
= 28 V, Ii = 280 mA, Pi = 0.850 W, L
i
= 28 VDC, Ii = 280 mA, Pi = 0.850 W , Li = 3.50 μH, Ci = 0.374 μF
IMPORTANT: MPI-F level sensor MUST be installed according to drawing 9009451
(Intrinsically Safe Installation Drawing for Hazardous Locations) on page 23 to meet listed
approvals. Faulty installation will invalidate all safety approvals and ratings.
DANGER: OPEN CIRCUIT BEFORE REMOVING COVER or KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE;
AVERTISSEMENT -- COUPER LE COURANT AVANT D’ENLEVER LE COUVERCLE, ou GARDER LE COUVERCLE
FERME TANT QUE LES CIRCUITS SONT SOUS TENSION.
DANGER: WARNING -- EXPLOSION HAZARD -- SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY
FOR CLASS I, DIVISION 2;
AVERTISSEMENT -- RISQUE D’EXPLOSION -- LA SUBSTITIOND E COMPOSANTSP EUTR ENDRE CE MATERIEL
INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I, DIVISION 2.
DANGER: WARNING -- EXPLOSION HAZARD -- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS
BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS;
AVERTISSEMENT -- RISQUE D’EXPLOSION -- AVANT DE DECONNECTER L’EQUIPEMENT, COUPER LE COURANT
OU S’ASSURER QUE L’EMPLACEMENT EST DESIGNE NON DANGEREUX.
Warranty and Warranty Restrictions
This product is covered by APG’s warranty to be free from defects in material and workmanship under
normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit
https://www.apgsensors.com/about-us/terms-conditions. Contact Technical Support to receive a Return
Material Authorization before shipping your product back.
Scan the QR code below to read the full explanation of our Warranty on your tablet or smartphone.
Model Number: MPI - _F_ __5__ _____ - _____ _____ - _____ _____ _____ __B__ - _____ - _____ - _____
A B C D E F G H I J K L
A. Stem Type
□ F 7/8 in. diameter Flexible Tubing with Braid, 316L SS
B. Output
□ 5 Modbus RTU, with surge protection, Intrinsically Safe
C. Housing Type
All Housing Die-cast Aluminum, NEMA 4X, IP68, Blue
▲
□ __
Large Housing
□ B Large Housing with window
D. Float 1 (Top Float)
□ Z 5.5h x 3d in. Red Polyurethane (0.65 SG)
□ Y 5.5h x 3d in. Blue Polyurethane (0.94 SG)
□ X 5 in. Round 316L SS (0.52 SG)
□ W 5 in. Round 316L SS (0.92 SG)
□ V 6h x 3d in. Oval 316L SS (0.58 SG)
□ U 6h x 3d in. Oval 316L SS (0.94 SG)
□ T 3 in. Round 316L SS (0.60 SG)
□ S 3 in. Round 316L SS (0.94 SG)
□ M 5.5h x 2d in. Red Polyurethane (0.57 SG)
□ L 5.5h x 2d in. Blue Polyurethane (0.94 SG)
□ J 5h x 3d in. Oval Titanium 2 (0.60 SG)
□ I 5h x 3d in. Oval Titanium 2 (0.92 SG)
□ N None
E. Float 2 (optional)
□ N None
□ Y 5.5h x 3d in. Blue Polyurethane (0.94 SG)
□ W 5 in. Round 316L SS (0.92 SG)
□ U 6h x 3d in. Oval 316L SS (0.94 SG)
□ L 5.5h x 2d in. Blue Polyurethane (0.94 SG)
□ I 5h x 3d in. Oval Titanium 2 (0.92 SG)
F. Mounting Type
□ F Flat Face ANSI Flange 150#
(Sizes: 2, 2.5, 3, 4, 5, 6)
□ R Raised Face ANSI Flange 150#
(Sizes: 2, 2.5, 3, 4, 5, 6)
□ S Tri Clamp
(Sizes: 2, 2.5, 3)
□ P NPT Plug 150#
(Sizes: 2, 2.5, 3, 4)
□ N None
G. Mounting Size
□ __ See Mounting Type for available sizes
H. Mounting Connection
□ W Welded (xed)
□ S Slide with Compression Fitting (adjustable)
I. Stem Material
□ B 316L SS
J. Total Stem Length in Inches
□ __ Min. 120 in. - Max. 300 in.
K. Temperature Sensor Options
□ N None
▲
□ 1D
Digital Temperature Sensor A, 12 in. from bottom of
probe
□ 2D Digital Temperature Sensors A, B
□ 3D Digital Temperature Sensors A, B, C
□ 4D Digital Temperature Sensors A, B, C, D
□ 5D Digital Temperature Sensors A, B, C, D, E
□ 6D Digital Temperature Sensors A, B, C, D, E, F
□ 7D Digital Temperature Sensors A, B, C, D, E, F, G
Note: Temperature sensors B - G are spaced evenly between
A and probe’s zero reference, with minimum of 2 in.
required between temperature sensors.
L. Housing Connection
▲
□ N
None
□ A 3/4” to 1/2” NPT Reducing Threads
□ B Cable Gland (Cable sold separately)
□ M 4-pin M12 Micro Connector Male
□ F 4-pin M12 Micro Connector Female
Note: When connecting MPI
sensors to your system, reversing
A and B connections may be necessary
if sensors do not communicate with
Modbus Master device.
MPI SensorMPI SensorMPI Sensor
Sensor 1
V+
B (TX-)
A (TX+)
GND
Sensor 2
V+
B (TX-)
A (TX+)
GND
Modbus System Wiring with RST-6001 For MPI-F Sensors
Power
Supply
+8-24 Vdc
GND
Use Shielded Cable
Wiring T’s must be located on
controller/supply side of IS barriers.
See Hazardous Installation
Drawing for Intrinsically Safe
Wiring T’s must be located on
controller/supply side of IS barriers.
RST-6001
Modbus
Controller
USB to computer
with APG Modbus
software
Note: An independent +8-24 Vdc
power supply is required when using
an RST-6001 Modbus Controller. The
RST-6001 can only supply ±5 Vdc, not
the +8-24 Vdc required by the MPI.
IMPORTANT: Refer to Chapter 5 for Intrinsically Safe Installation Drawing for Hazard-
Chapter 2: Installation and Removal Procedures and Notes
• Tools Needed
You will need the following tools to install your MPI level sensor:
• Wrench sized appropriately for MPI mounting
• Wrench sized appropriately for conduit connections
• Flat-head screwdriver for wire terminals
• Channel lock pliers for tightening compression tting
• 1/8” Hex Allen wrench for screws on oat stop(s).
• Pliers for bending cotter pin.
• ATEX Stated Conditions of Use
• Under certain extreme circumstances, the non-metalic parts incorporated in the enclosure of this
equipment may generate an ignition-capable level of electrostatic charge. Therefore the equipment
shall not be installed in a location where the external conditions are conducive to the build-up of
electrostatic charge on such surfaces. In addition, the equipment shall only be cleaned with a damp
cloth.
• The enclosure is manufactured from Aluminum. In rare cases, ignition sources due to impact and
friction sparks could occur. This shall be considered during installation.
• Physical Installation Notes
The MPI-F should be installed in an area--indoors or outdoors--which meets the following conditions:
• Ambient temperature between -40°C and 85°C (-40°F to +185°F)
• Relative humidity up to 100%
• Altitude up to 2000 meters (6560 feet)
• IEC-664-1 Conductive Pollution Degree 1 or 2
• IEC 61010-1 Measurement Category II
• No chemicals corrosive to stainless steel (such as NH3, SO2, Cl2)
• Ample space for maintenance and inspection
Additional care must be taken to ensure:
• The probe is located away from strong magnetic elds, such as those produced by motors, transform-
ers, solenoid valves, etc.
• The medium is free from metallic substances and other foreign matter.
• The probe is not exposed to excessive vibration.
• The oat(s) t through the mounting hole. If the oat(s) does/do not t, it/they must be mounted on
the stem from inside the vessel being monitored.
• The oat(s) is/are oriented properly on the stem (See Figure 2.1). MPI-F oats are installed by customer.