Intrinsically Safe Ultrasonic Level
Sensor with 4-20 mA Output
Series: LPU-2428
®
With Class 1 Division 1 ratings, the loop powered LPU-2428 is built to handle the most hazardous locations. Add the ability to
internally calculate volume or open channel ow data, and you have a unique and powerful ultrasonic sensor.
Features
• Loop powered 4-20 mA output
• Class 1 Division 1, Intrinsically Safe rating
• Built-in calculations of current volume, ow, and ow totals
C
US
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
Rev. B, 04/20/2016

LPU-2428 Specications
Liquid Tight
Non-Metallic
Spiral Strain Relief
®
3/4” NPT
Threads
2” NPT
Threads
50.54 mm
Performance
• Operating Range
1 - 25 ft. (0.3 - 7.6 m) on liquids
1 - 10 ft. (0.3 - 3 m) on solids
• Beam Pattern: 9º o axis
• Internal Temperature Compensation
• Frequency: 69 kHz
• Accuracy: ±0.25% of detected range
• Resolution: 0.1 in. (2.5 mm)
• Response Time: Dependent on output, ranges from
0.6 - 3 seconds
Connectivity
• Output: 4-20 mA (loop powered)
• Loop Resistance: 600 ohms @ 24 VDC
150 ohms @ 12 VDC
• Network/Web with the RST-5000 series module or LOE
Environmental
• Ratings: IP65
• Operating Temp: -40º - 140ºF (-40º - 60ºC)
Certication
• Class 1, Div. 1, Groups C & D
• Class 1, Zone 0, AEx iA IIB, T3; IP65
7.23”
183.64 mm
5.10”
129.54 mm
3.05”
77.47 mm
1.49”
37.84 mm
1.99”
Electrical
• Total Current Draw: 4-20 mA
• Supply Voltage: 12-28 VDC
• Wiring Connection: 2-conductor shielded cable
Programming
• Interface with RST-4101 USB Module
(purchase separately)
-The RST-4101 is powered by a USB port connecting the
RST to a computer. A 2-conductor terminal strip allows the
module to be connected in parallel with the 4-20 mA loop.
• Volume Measurement Settings:
Formulas for a wide variety of common tank types
• Flow Measurement Settings:
Formulas for a wide variety of weirs and umes total
ow counter
• 32-point linearization table for unique tanks, weirs, and
umes
• User selected units of measure
Physical
• PVDF (Kynar®) transducer housing
• PC/PBT upper housing
• Transducer Type: Ceramic, PVDF faced
Model Conguration Options
Model Number: LPU-2428 - C______ Cable length in feet (6 ft. is standard)
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
Document #9004574 Rev. B, 04/20/2016