Intrinsically Safe Ultrasonic Level Sensor with 4-20 mA Output Series: LPU-2428
®
internally calculate volume or open channel ow data, and you have a unique and powerful ultrasonic sensor.
Features
Loop powered 4-20 mA output
Class 1 Division 1, Intrinsically Safe rating
Built-in calculations of current volume, ow, and ow totals
C
US
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
Rev. B, 04/20/2016
Page 2
APG
LPU-2428 Specications
Liquid Tight
Non-Metallic
Spiral Strain Relief
®
3/4” NPT
Threads
2” NPT
Threads
50.54 mm
Performance
Operating Range
1 - 25 ft. (0.3 - 7.6 m) on liquids 1 - 10 ft. (0.3 - 3 m) on solids
Beam Pattern: 9º o axis
Internal Temperature Compensation
Frequency: 69 kHz
Accuracy: ±0.25% of detected range
Resolution: 0.1 in. (2.5 mm)
Response Time: Dependent on output, ranges from
0.6 - 3 seconds
Connectivity
Output: 4-20 mA (loop powered)
Loop Resistance: 600 ohms @ 24 VDC
150 ohms @ 12 VDC
Network/Web with the RST-5000 series module or LOE
Environmental
Ratings: IP65
Operating Temp: -40º - 140ºF (-40º - 60ºC)
Certication
Class 1, Div. 1, Groups C & D
Class 1, Zone 0, AEx iA IIB, T3; IP65
7.23”
183.64 mm
5.10”
129.54 mm
3.05”
77.47 mm
1.49”
37.84 mm
1.99”
Electrical
Total Current Draw: 4-20 mA
Supply Voltage: 12-28 VDC
Wiring Connection: 2-conductor shielded cable
Programming
Interface with RST-4101 USB Module (purchase separately)
-The RST-4101 is powered by a USB port connecting the RST to a computer. A 2-conductor terminal strip allows the module to be connected in parallel with the 4-20 mA loop.
Volume Measurement Settings: Formulas for a wide variety of common tank types
Flow Measurement Settings: Formulas for a wide variety of weirs and umes total ow counter
32-point linearization table for unique tanks, weirs, and umes
User selected units of measure
Physical
PVDF (Kynar®) transducer housing
PC/PBT upper housing
Transducer Type: Ceramic, PVDF faced
Model Conguration Options
Model Number: LPU-2428 - C______ Cable length in feet (6 ft. is standard)
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com