APG LPU-2127 Specifications

APG
LPU-2127 Loop Powered Ultrasonic Sensor
®
C
US
With a built in keypad for easy programming and exibility, the LPU-2127 provides continuous level/distance measurement you can count on. Its durability, range, and simplicity make it a great sensor for many applications.
Features
1 - 25 ft. (0.3 - 7.6 m) detection range on liquids
Loop powered 4-20 mA output
Integrated keypad and LCD display
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
Rev. A, 08/28/2015
APG
LPU-2127 Specications
or Input Card
6.05”
153.7 mm
5.5”
139.7 mm
®
4.00”
101.6 mm
2.4”
60.96 mm
2” NPT
2.3”
58.42 mm
Performance
• Operating Range
1 - 25 ft. (0.3 - 7.6 m) on liquids
1 - 10 ft. (0.3 - 3 m) on solids
• Beam Pattern: 9º o axis
• Internal Temperature Compensation
• Frequency: 69 kHz
• Accuracy: ±0.25% of detected range
• Resolution: 0.1 in. (2.5 mm)
• Response Time: Dependent on output ranges from 0.6 - 3 seconds
• Sample Rate: 3 seconds at 4mA - 0.6 seconds at 20mA
Connectivity
• Output:
4-20 mA (loop-powered) 600 ohms @ 24 VDC 150 ohms @ 12 VDC
Environmental
• Ratings: IP65
• Operating Temp: -40º - 140ºF (-40º - 60ºC)
Certication
• Class 1, Div. 2, Groups C & D
• Class 1, Zone 2, AEx nA IIB T6
Electrical
• Cable Connection: 2-terminal connector
• Total Current Draw: 4-20 mA
• Supply Voltage: 12-28 VDC
Programming
• Integrated keypad and LCD display
Physical
• PVDF (Kynar®) transducer housing
• PET upper housing
• Transducer Type: Ceramic, PVDF face
4 to 20ma Out
+24vdc
4.25
Ammeter
COM
mA
Power Supply (24Vdc)
+
-
Model Conguration
Model Number: LPU-2127
Load Resistance
Automation Products Group, Inc. | 888.525.7300 | sales@apgsensors.com | www.apgsensors.com
Document #9004573 Rev. A, 08/31/2015
Loading...