MICROTECHNOLOGY
HTTP://WWW.APEXMICROTECH.COM (800) 546-APEX (800) 546-2739
FEATURES
• LOW COST 200°C VERSION OF PA12
• OUTPUT CURRENT at 200°C — ±1A
• FULL SPECIFICATIONS — –25°C to +125°C
• WIDE SUPPLY RANGE — ±10 to ±45V
• CURRENT FOLDOVER PROTECTION
• EXCELLENT LINEARITY — Class A/B Output
POWER OPERATIONAL AMPLIFIER
PA12H
APPLICATIONS
• MOTOR, VALVE AND ACTUATOR CONTROL
• POWER TRANSDUCERS UP TO 100kHz
• PROGRAMMABLE POWER SUPPLIES UP TO 80V
• TRANSMISSION LINE DRIVER
DESCRIPTION
The PA12H is a low cost, high temperature Power Op Amp
made especially for short term use in extreme environmental
situations such as down hole instrumentation. The amplifier
can power mechanical or electronic transducers and can drive
the long transmission lines associated with these applications.
The PA12H, based on the standard PA12’s very high power
level, leaves a six watt capability after being derated for
operation at a case temperature of 200°C. To meet the high
temperature requirements for up to 200 hours, polyimid has
replaced the standard epoxy for attaching the small signal
devices.
These hybrid integrated circuits utilize thick film conductors,
ceramic capacitors and silicon semiconductors to maximize
reliability, minimize size and give top performance. Ultrasonically bonded aluminum wires provide reliable interconnections at all operating temperatures. The 8-pin TO-3 package
(see Package Outlines) is hermetically sealed and isolated.
The use of compressible thermal washers and/or improper
mounting torque will void the product warranty. Please see
“General Operating Considerations”.
CALCULATED LIFE EXPECTANCY
1000
100
EXPECTED LIFE, HOURS
10
188 192 196 200
SPECIFICATIONS
Specifications of the standard PA12 apply to the PA12H
with the exception of the temperature range extensions
1. The operating and storage temperature ABSOLUTE MAXIMUM RATINGS extend to +200°C.
2. Static and dynamic tests are performed at +125°C as
shown in SG 2 and SG 5 of the military PA12M data sheet.
3. Additional tests at T
A. Quiescent current = 100mA max at ±V
B. Voltage swing = ±V
= 200°C:
C
–4 (IO = 1A, ±VS = 15)
S
= 45.
S
GENERAL CONSIDERATIONS
The primary aim of the PA12H is to provide a reasonable
level of power output at a minimum cost. To achieve this end,
full dynamic tests are performed up to 125°C, with only
minimal 100% testing at 200°C. This approach saves nearly
an order of magnitude over the cost of a fully tested long life
product, but does require recognition of two limitations.
First, input parameters such as voltage offset and bias
current are not tested above 125°C. This could lead to accuracy problems if the PA12H is used as a precision computational element. Solutions to this limitation include contacting
the factory regarding additional testing at higher temperatures
or using high temperature small signal amplifiers for computational tasks.
The second limitation of life span requires the PA12H to be
used in short term applications. This requirement is mandated
by the low cost design concept. At 200°C component degradation is nearly as severe during storage as during actual
operation. This must be taken into account when scheduling
actual implementation of the finished package.
Please consult the PA12 data sheet for basic information on
this amplifier; the PA12M data sheet for details on +125°C
tests, and Power Operational Amplifier handbook section
“General Operating Considerations,” for recommendations on
supplies, stability, heatsinks and bypassing.
EXTERNAL CONNECTIONS
CL+
+IN
–IN
+V
S
4
5
–V
3
TOP VIEW
6
S
2
7
F.O.
R
CL+
OUT
1
8
R
CL–
CL–
OUTPUT
This data sheet has been carefully checked and is believed to be reliable, however, no responsibility is assumed for possible inaccuracies or omissions. All specifications are subject to change without notice.
APEX MICROTECHNOLOGY CORPORATION • 5980 NORTH SHANNON ROAD • TUCSON, ARIZONA 85741 • USA • APPLICATIONS HOTLINE: 1 (800) 546-2739
PA12HU REV. H FEBRUARY 1998 © 1998 Apex Microtechnology Corp.