OPERATION MANUAL

BILIRUBIN METER

BR – 5000N

IMPORTANT!

READ THIS OPERATION MANUAL!

*Prior to operation, please read this manual carefully and retain it for future reference. Failure to read, understand and follow the instructions in this manual may result in damage to the unit, injury to operating personnel and/or poor equipment performance.

All rights are reserved. This material may not be reproduced or copied, in whole or part, without the written permission of APEL CO., LTD.

BR5N-1-OMA-103a

 

TABLE OF CONTENTS

 

Section 1 - Introduction

 

1.1

Introduction ---------------------------------------------------

2

1.2

Features ------------------------------------------------------

2

1.3

Important Safety Instruction ------------------------------

4

Section 2 – Contents of the unit

 

2.1 Description of the unit --------------------------------------

6

2.2 Control panel Keys, Display and Indicator --------------

7

Section 3 – Operation procedure

 

3.1

Preparation ----------------------------------------------------

8

3.2

Taking blood sample -----------------------------------------

8

3.3

Measurement of the specimen ------------------------------

10

3.4

Setting the name or ID number of the test ------------------

12

3.5

Other functions -----------------------------------------------

12

3.6

How to use Serum gauge ------------------------------------

15

Section 4 – Maintenance and inspection

 

4.1

Adjustment with standard solution ------------------------

16

4.2

Indication of alarms --------------------------------------------

17

4.3

Inspection abnormalities -------------------------------------

17

4.4

Light bulb replacement --------------------------------------

18

Section 5 – Specifications

 

5.1

Specifications --------------------------------------------------

19

1

BR5N-1-OMA-103a

Section 1 - Introduction

1.1 Introduction

Congratulations on purchasing an APEL product. It’s an important and very smart decision that’s sure to reward you for many years to come. To ensure that you take full advantage of our Bilirubin meter, BR-5000N’s offered features and warranty benefits, be sure to carefully read and fully comprehend this Operation Manual.

It is designed to acquaint you with the features and help you effectively operate the new instrument in safety. We sincerely hope you will enjoy many benefits of being associated with our product which represents both quality and customer satisfaction. We are proud of the advanced engineering and quality construction of each instrument we build. If you have any questions, please contact your supplier and refer to the model number and seven-digit serial number located at the back of your unit, when inquiring.

The BR-5000N Bilirubin meter is a digital, direct reading measuring equipment developed with the purpose of enabling the measurement of total bilirubin in serum of neonate while compensating for hemolysis, turbidity, and other components of obstruction. With the BR-5000N, an alarm is displayed automatically whenever there is a high-density specimen or a high level of obstruction that falls outside the tolerance.

1.2 Features

1.Handles hemolysis and turbidity easily

Careful selection of the dual wavelength color filters and the combination of electronic technology minimize the interference of hemolysis and turbidity.

2.Easy operation

Microprocessor enables the Auto Calibration and easy operation. And after the equipment is calibrated with a standard solution, you can measure specimen without using the standard solution after that.

3.Easy set of the sample tube

A serum gauge is provided on the surface of BR-5000N, which indicates the proper sample volume to be inspected. Only simple action is required to set the capillary tube into the holder.

4.Alarm lamp informs user of abnormalities

Alarm lamp signals either abnormal value or situations such as burned out of the bulb, bilirubin concentration of 30mg/ or more, or high hemolysis of 250mg/ or more.

2

BR5N-1-OMA-103a

5. The print out by the printer

The measurement data can be printed out by the option printer.

(The measurement data are memorized up to 100 samples in maximum while the power switch in being turned on.)

The printer connector is based on Centronics standard.

6. The equipment can be connected to computer by serial interface.

The measurement data can be sent to computer through RS-232C interface.

7.mg/ - and μmol/ℓ -indication

One of mg/ - and μmol/ℓ -indication can be selected by the control panel.

8.Easy to operate by on touch key.

Normal measurement can be performed by touching start button after inserting the capillary tube to the capillary tube holder.

9.Compact design

BR-5000N has a compact design that does not occupy much space.

10.Flexible power source

Power requirement is flexible, from 100 to 240VAC.

3

BR5N-1-OMA-103a

1.3Important Safety Instruction

When utilizing your BR-5000N, always take basic safety precautions and warnings, in order to avoid damage to your unit, property and/or personal injury, which may result from misusage, exposure to fire or electric shock. Important warnings and safety precautions are as follows:

1.To ensure accuracy of the measurement, always warm-up the instrument for at least 15 minutes, prior to operation.

2.Never cover the unit when it is turned-on. Doing so will prevent the electrical components from being cooled properly and cause damage.

3.Unplug the BR-5000N from the wall outlet prior to cleaning. Do not use organic liquid solutions such as alcohol or aerosol cleaners. Use a soft dry cloth for cleaning.

4.Do not directly expose your unit to water or liquid. Avoid spills, which could damage electronic components.

5.Always use appropriate capillary tube in specification, when obtaining bilirubin’s data or using standard solution.

6.Place this product on stable cart, stand, or table.

7.If stored in non-room temperature setting, allow the unit to reach room temperature before turning on. Do not place this instrument in an environment where there is severe temperature variation.

8.Place the unit away from dust, excessive moisture, or corrosive chemicals. Cover the instrument when not in use to protect electrical components from dust.

9.Do not dismantle or modify the instrument. Damage or performance problems resulting from disassembly or alteration of the unit, will not be covered under the warranty. Contact your supplier when maintenance, service or repair work are required.

10.When instrument is not in use, make sure the power switch has been turned-off and unplug the power cord from the electrical outlet. Do not pull the cord, but hold the receptacle of the plug and pull it.

11.Only use light bulb, capillary tubes and power cord that come with this instrument. Such replacement parts are available through your supplier.

12.Do not overload wall outlets with extension cords as this can result in the risk of fire or electric shock. Attaching multiple loads to the same wall outlet is dangerous and may cause improper operation of BR-5000N.

4

BR5N-1-OMA-103a

13.Do not allow anything to rest on the power cord. Do not locate this product where the power cord may trip any person or object.

14.To keep the accuracy of this instrument, calibration should be done periodically and after a period of long storage prior to operation.

15.Make sure that the GND code is grounded properly.

16.Unplug this product from the outlet and refer to your supplier under the following conditions:

*When the power cord or plug is damaged and/or frayed.

*If the unit has been directly exposed to water or liquid.

*If the instrument displays unusual change in performance.

*If the instrument has been abused or dropped.

*If the unit does not function normally by following the operating instructions. (Adjust only those controls that are presented and mentioned in the instruction.)

*IT IS OWNER’S RESPONSIBILITY TO MAKE SURE THAT THE SPECIFIED SAFETY AND OPERATING INSTRUCTIONS ARE FOLLOWED.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.