American Power Conversion S10, S10BLK, S15BLK, S15 User Manual

Model S15 Shown
S Type Power Conditioner
with Battery Backup
Owner's Manual
Models: S10, S10BLK, S15,
and S15BLK
Safety Information
1. Read this manual - Read all of the safety and operating instructions before
installing and operating this device.
2. Keep this manual - Retain this manual, and all of the safety information that
came with this device.
3. Warnings - Comply with all warnings presented in this manual, as well as any
found on the device.
4. Follow Instructions - Follow all operating and use instruction.
5. Cleaning - Shut off and unplug this device from the wall outlet before
cleaning. Use a soft cloth dampened with mild soap or water only. Do not use ammonia or alcohol-based cleaning agents. Note: Any equipment connected to this device will not be powered or protected from uninterrupted service during this process.
6. Water and Moisture - Do not use this product near any source of water, or in
an environment where the relative humidity may exceed 95% (non­condensing).
7. Placement - Do not install this device on any unsteady surface. Do not install
this device on any heat source. If the APC unit is not being rack-mounted, place it on a surface capable of supporting at least 60 lbs.
8, Ventilation - Do not install this device in an area where the vents provided for
cooling purposes may become obstructed.
9. Power - Ensure this device is connected to a properly grounded AC power
source. Further ensure the device is plugged into a source providing the required 120 Vac. Do not use a plug adapter which defeats the ground pin of the AC plug.
10. Polarization - This device has a polarized AC line plug with two blades and a
ground pin. This plug fits into the wall outlet only in one orientation because of
!
the ground pin. This is a safety feature. Do not remove the round grounding pin, or use an adapter that defeats this safety feature.
11. Power Cord - Ensure power cords are routed in a manner that will preclude
them being pinched, frayed, or stepped on. After connecting other devices to this device, do not push the rear panel of the device up against any surface (wall or shelving unit), as this may create an undesired bend in the power cords which may break the wire strands of the cord.
12. Antenna Grounding - Although this device provides protection against
electrical surges, when connecting an outside antenna or cable system to devices connected to this device, ensure the antenna or cable system is grounded so as to provide additional protection against voltage surges and static charges in accordance with Section 810 of the National Electric Code, ANSI/NFPA No.70 (see illustration - next page).
13. Other Grounding - This device provides a grounding lug at the rear panel for
grounding the device to an external Transient Voltage Surge Suppression (TVSS) device. Ensure this connection is made in accordance with the instructions provided by the TVSS device.
14. Lightning - This device employs Metal Oxide Varisters (MOVs), and other
circuitry to protect against lightning and other sources of voltage surges and sags. It is not necessary to turn this device or the devices connected to this device, off during a lighting storm.
15. Power Lines - Do not locate outside antenna systems near overhead power
lines, or other electric light or power circuits, or where it may fall or otherwise come in contact with these power sources. Do not allow the ladder being used, or the antenna itself to come into contact with these power sources, as such contact may be fatal.
Safety Information (continued)
16. Overloading - Do not overload the wall outlet where this device is being
connected. Do not overload this device. Ensure the total load to this device does not exceed that which is listed in the Specifications section of this manual.
17. Openings - Do not push any object into the vents provided for cooling, as
such an object may come into contact with high-voltage components.
Warning: This may cause injury, death, or damage to the device. Do not allow liquids to enter any opening in this device.
18. Servicing - There are no user-serviceable components within this device
other than the battery pack. Removal of any cover, other than the front bezel, from this device may present a shock hazard, and/or void the warranty.
19. Damage Requiring Service - If any type of damage occurs to this device,
immediately disconnect it from the wall outlet. Do not use the Power switch or line cord into the rear of the device to disconnect power. Notify APC Technical Support or Customer Service at once.
20. Replacement Parts - There are no components within this device that can or
should be removed/replaced, other than the battery pack, unless it is performed by an APC-qualified technician.
21. Periodic Inspection - Inspect the line cords, telephone/data line cords, and/
or DSS/Cable TV coaxial cables connected to this device to ensure they remain fully pushed in or attached and have no apparent damage.
EXAMPLE OF ANTENNA GROUNDING AS PER NATIONAL ELECTRIC CODE (NEC)
Ground
Electric Service
Equipment
ii
Clamp
Antenna Lead-In Wire
Antenna Discharge Unit
Grounding Conductors
Ground Clamps
Power Service Grounding
Electrode System
Protect Your Investment
Thank you for selecting APC's S Type Power Conditioner with Battery
Backup. At APC, we know you have made an intelligent choice sure to reward
you for many years. To ensure you receive all the benefits and protection
which accompany your purchase, please take a few minutes to fill out and
mail the enclosed Warranty Registration Card, or complete the online form at
www.apcav.com.
Note: Under California law, failure to register your purchase may not exclude
you from provisions of the Warranty and Equipment Protection Policy.
Benefits of warranty registration are outlined below.
Registration Verification Confirmation
By registering your purchase now, it guarantees you will receive all the information and special offers you qualify for as the owner of this product.
By registering your purchase now, it confirms your right to maximum protection under the terms and conditions of the Warranty, and Equipment Protection Policy.
By registering your purchase now, you have a way to confirm yourself as the owner of the product in the event of fire, theft or loss.
Safety Symbols
This “bolt of lightning” indicates uninsulated material within your unit that may cause an electrical shock. For the safety of everyone in your home, please do not remove the product cover.
This “exclamation point” calls attention to features for which
!
you should read about in this Manual to prevent operating and maintenance problems.
Warnings, Cautions and Notes
Warnings Cautions Notes Warnings provide information about a procedure that, if not performed exactly as stated, may result in injury or death.
Cautions provide information about a procedure that, if not performed exactly as stated, may result in equipment damage.
iii
Notes provide information that is essential to highlight.
iv
Table of Contents
Safety Information i
Protect Your Investment iii
Introduction 1-1
Proven Expertise… Proven Reliability 1-2 Safety Precautions 1-2 Package Contents 1-2 Unit Power Capacity 1-3 Features 1-3 Front and Rear Panels 1-5
Installation 2-1
Removing the Battery Pack 2-1 Placing the Unit 2-1 Inserting and Connecting the Battery 2-3 Powering On and Connecting Equipment 2-5 Performing the System Test 2-5 Status and Informational Screens 2-9 Connecting the Components 2-14 Setting Up the S10 or S15 Using the Front-Panel Controls 2-15
Warranty 3-1
Contact Information 4-1
Specifications A-1
Troubleshooting B-1
Unit will not turn on. B-1 Connected equipment reboots or turns off during or after the unit switches to battery power. B-2 Replace Battery” LED is illuminated. B-3
v
vi
Chapter
1
Introduction
Congratulations on your purchase of APC’s Model S Type Power Conditioner with Battery Backup (Model S15 shown in Figure 1). Your unit will protect your high performance audio and video (AV) system from damaging power surges, spikes and lightning, as well as power outages. Protection is guaranteed. Isolated noise filter banks and Automatic Voltage Regulation (AVR) will eliminate power as a source of audio and video signal degradation. Pure sine wave battery backup power will prevent interruptions, lost pre-sets, missed DVR recordings and lost media server data when the power goes out. Data-line surge protection jacks will stop surges traveling over phone or data lines.
Digital Satellite System, Cable Modem, and CATV Coaxial Cable lines are equally protected. With APC’s S Type, your entire home entertainment experience is bullet-proofed from damage or interruption as a result of bad power. With APC’s Power Conditioner with Battery Backup, you can enjoy your home theater experience with the peace of mind that performance is optimized and protection is guaranteed.
Figure 1. S15 Power Conditioner with Battery Backup (Front View)
1-1
Proven Expertise Proven Reliability
From corporate data centers to home offices, APC is regarded as an innovator, designer and manufacturer of high-quality power protection solutions. With a proven reputation for Legendary ReliabilityTM, leading companies depend on APC every day to protect and support many of the most critical networks in the world, including those at Microsoft®, Toyota® Motor Sales, Inc., and IBM®. Over the last 20 years, APC has been a pioneer in the development of new power protection technologies that have resulted in countless industry awards, design patents and an installed-base numbering in the tens of millions of units. Multiple R&D centers, along with APC-owned and controlled factories ensure APC solutions are the safest, most advanced and reliable products available. When you buy APC, you buy “peace of mind”.
Safety Precautions
Please ensure you have read and understand all of the safety information located at the front of this manual. If you have any questions about the safety information, or are concerned that your home may not be properly wired for this equipment, please contact APC Technical Support or a qualified and licensed electrician.
Package Contents
NOTE: The Sxx and SxxBLK models have the same performance, features and functionality. The only difference is color. In this manual, "S10" and "S15" will be used to refer to both the silver and black models.
Your Power Conditioner with Battery Backup package includes the following components:
• 1 Power Conditioner with Battery Backup (battery pack included)
• 1 Front Display Panel (Bezel)
• 1 Input Power Cord
• 3 Coaxial Patch Cables
• 1 DC Trigger Cable
• PowerChute Personal Edition Software CD
• USB Interface Cable
• 1 Telephone Patch Cable
• 1 Ethernet Patch Cable (not available with S10)
• 1 User Manual
• 1 Equipment Protection Policy Sheet
• 1 Warranty Card
1-2
• 1 Rack-mount Kit (2 rails, 2 ear brackets, screws, and instruction sheet)
If any items are missing, please contact APC Customer Service.
Unit Power Capacity
The S10 Power Conditioner is rated for 700 watts (continuous), and the S15 is rated for 900 watts (continuous). They have been designed, however, to support component inrush currents that are much higher than their continuous power rating. The S10 and S15 are capable of supplying the dynamic peak current draws required by any component designed to work on a 15 amp circuit. Despite their nameplate power ratings, high performance AV equipment draw much less than their listed power ratings. The S10 and S15 can inform the user how much of the power capacity is available as equipment is connected to the unit.
Features
The following are major features of the Model S10 and S15.
Pure Sine Wave Battery Backup
Both models provide battery backup power to maintain pure, uninterrupted power for your home theater and automation systems in the event of a power blackout. Battery backup power not only prevents interruptions in your entertainment, it also helps prevent lost pre-sets, lost multi-media server data, damaged hard drives, and premature projector bulb wear and tear.
Automatic Voltage Regulation (AVR)
The S10 and S15 are unique in that they provide AVR, which is engaged to correct low and high voltage conditions. In doing so, all equipment connected to the S10 or S15 are protected against these undesired voltage fluctuations, thus prolonging the life of the equipment. Low voltage conditions can also negatively impact video quality. AVR, therefore, may help improve picture quality if low voltage conditions are present.
Surge Protection
The S10 and S15 provide guaranteed protection against damaging surges, spikes and even lightning. The S-Type not only provides protection from surges traveling over AC power lines, protection is also offered against surges traveling over system data lines including COAX, telephone and Ethernet lines (varies by model, see Specifications table). With APC your entire investment in component hardware is protected.
1-3
Isolated Noise Filter Banks
Both models eliminate electromagnetic and radio frequency interference (EMI/RFI) that, when severe enough, can negatively impact sound and video quality. Each filter bank is electrically isolated from each other to prevent noise generated by one component from polluting other connected components. APC's noise filtering helps enable your system perform to its maximum capabilities.
DC Trigger
When connected to a component acting as a DC trigger, that component controls the turning on/off, as well as sequencing of the ‘delayed’ outlet banks. The S10 and S15 also allows that DC signal to pass through to another connected component.
Rack-mountable
Rack-mount hardware is included to mount the unit into any 4-post, 19" rack. See below for more information.
Sequenced Turn ON/OFF
This feature ensures that connected equipment is powered-up/down in the proper order and with the right amount of delay between the stages. It allows the user to program a delay into the sequence between 0 and 10 seconds. This delay eliminates transients that can affect connected components or cause the building circuit breaker to trip.
1-4
Front and Rear Panels
The following sections describe the controls and indicators on the front and rear panels.
Front Panel Controls and Indicators
The front panel controls and indicators for the S10 and S15 Power Conditioners are identical, and are detailed in Figure 2. Each numbered callout refers to the numbered description found immediately following the picture.
1 3 5 6 7
DELAYED 1 Status Indicator
1
2
13
14
Figure 2. S15 Front Panel Controls and Indicators
4
1112
10
8
9
When lit (blue), conditioned power is being supplied to equipment connected to the rear-panel outlets marked Delayed 1 .
ON BATTERY Status Indicator
2
When lit (orange), the Power Conditioner is operating on power from the internal Battery Pack and is providing clean power to the connected equipment. The unit will go On Battery when the input utility voltage has either dropped below the user-selectable level, gone above the user-selectable level, or is experiencing an outage, or momentary drops or surges of the input utility voltage.
1-5
STATUS Push Button
3
25
When pressed, provides unit status for: Input and Output Voltage,
Input and Output Frequency , Telephone and Internet contact
information, Model and Serial Number , Firmware (FW) Version number, Source ( Standby , Battery , or Utility ) and Estimated
Runtime (in hours or minutes), Estimated Runtime (in hours)
with a Fuel (as a percentage with bar graph) indication, as well as
System Load (in watts), and Load (as a percentage with bar
graph).
This push button can also be used to set a default screen, a screen that is displayed all the time.
Vacuum Fluorescent Display (VFD)*
4
Conveys information about unit and power status. It is also used to display information when making settings changes to the unit.
*Note - The VFD and Light Emitting Diodes (LEDs) can be
dimmed or turned off independently of each other via the front control panel SETUP push button.
5
Up Arrow Push Button
This button is used to change parameters (increase or turn on) for various user-selectable settings such as: Audible Alarms,
Sensitivity, Display Dimmer, LED Dimmer, Go To Bat If, Outlet 1 & 2 Delay (in seconds), Low Bat Warning, Bat Rep Date, etc.
LOW BATTERY Status Indicator
6
When lit (orange) indicates the Battery Pack charge level is low. When this indicator turns on, the user can set the value (from 2 to
minutes) to allow time to shut off power before the Battery Pack is fully discharged. When lit, leave the unit plugged in to allow batteries to recharge. The unit does not have to be powered on for batteries to recharge.
1-6
LINE OK Status Indicator
7
When lit, input voltage from the utility is within acceptable range. If not lit, the Automatic Voltage Regulation circuit is correcting high or low voltage levels to maintain safe voltage conditions for connected components, or the unit is operating on battery power due to a blackout or extreme voltage level conditions.
8
FILTERING
Status Indicator
When lit, notifies the user that the Electromagnetic Interference/Radio Frequency Interference (EMI/RFI) noise reduction circuit is active.
OVERLOAD Status Indicator
9
When lit (red) the unit is overloaded; unplug equipment connected to the unit until the indicator is no longer lit.
10
Down Arrow Push Button
Is used to change parameters (decrease or turn off) for various user-selectable settings such as: Audible Alarms, Sensitivity,
Display Dimmer, LED Dimmer, Go To Bat If, Outlet 1 & 2 Delay (in seconds), Low Bat Warning, Bat Rep Date , etc.
On/Off Switch
11
Controls power to all 12 outlets. APC recommends the unit be left ‘on’ at all times. Control power to your system and components using their own controls as you normally would.
SETUP Push Button
12
This push button is used to advance the display through the various user-selectable set up functions provided by the unit such as:
Audible Alarms , Sensitivity , Display Dimmer , LED Dimmer , Go To Bat If , Outlet 1 & 2 Delay (in seconds), Low Bat Warning , Bat Rep Date , etc.
REGULATING Status Indicator
13
When lit (blue), indicates Automatic Voltage Regulation (AVR) is engaged to correct low or high voltage conditions.
1-7
DELAYED 2 Status Indicator
14
When lit (blue), conditioned power is being supplied to equipment connected to the rear-panel outlets marked Delayed 2
.
1-8
Rear Panel Connectors, Indicator, and Circuit Breaker
The rear panel connectors for the S10 and S15 Power Conditioner are detailed in Figure 3. The only difference between the rear panels of the two models is that the S15 provides a coaxial cable splitter and jacks for surge-protection of Ethernet equipment, as well as a connector for an external Battery Pack (sold separately). Each numbered callout refers to the numbered description found immediately below the picture.
1 2 3 4 5
13
12
Figure 3. S15 Rear Panel Connectors, Indicator, and Circuit Breaker
12
91011
7
8
Note: All outlets provide surge protection, voltage regulation, noise filtering
and pure sine wave battery backup power.
1-9
6
1
Outlets -
The S10 and S15 Power Conditioner provides for connection of up to twelve (12) components. The outlets are arranged according to the type of filtering protection provided for a given component type. These Isolated Noise Filter Banks (INFBs) eliminate EMI and RFI that can negatively impact sound and video quality. APC recommends plugging your devices into the outlets as marked, in order to assure optimum protection for your equipment. The outlets are further defined in the following:
DIGITAL FILTER
Components (CD, DVD, DVR, CATV/SAT, Flat Panel Monitors, Hi-Def tuners, etc.).
Note
: Any digital device can be plugged into the
FILTER
outlets, any video device can be plugged into either of the
VIDEO FILTER
Outlets
outlets, etc. Example, if you have a cable box and
eliminate noise interference for Digital
DIGITAL
a satellite receiver, but no monitor, you can plug the cable box into the "
CATV/SAT
"
Monitor
VIDEO FILTER
and
VCR
).
ANALOG FILTER
" outlet, and the satellite receiver into the
" outlet.
Outlets provide filtering for video devices (TV
Outlets provides filtering for analog-based
equipment (TUNER/AUX and Preamp/Receiver).
HIGH CURRENT FILTER Outlets provide filtering for high-current devices (POWERED SUBWOOFER and
AMPLIFIER).
EXTERNAL BATTERY Connector
2
For the S15 only, it provides a connection for APC’s optional S-Type Extended Battery Pack. For additional information, please go to www.apcav.com, or inquire at your APC retailer.
1-10
Loading...