APC NET9RMBLK User Manual

SAVE THESE INSTRUCTIONS!
HORIZONTAL RAIL MOUNTING
INTERIOR HORIZONTAL MOUNTING RA ILS
BRACKET
VERTICAL EIA RAIL
(PERSPECTIVE ILLUSTRATES LOOKING INTO REAR O F CABINET)
THROUGH SIDE OF CABINET)
VERTICA L EIA RAIL
UNIVERSAL MOUNTING BRACKET
A
FORWARDS OR
3.50"
15' LONG
GROUND S CREW
PROTECTION WOR K ING
LED (GREEN)
FRONT VIEW
19.00"
o
LED(RE D)
CIRCUIT BREAKER
Thank you for selecting the SurgeArrest Rackmoun t from American Power Conversion! It is designed to provide the highest d e gree of protection from utility line spikes, surges and EMI/RFI noise. Please complete and return the enclosed w arranty registration card.
Surges are caused by nearby lightning activit y and motor load switch­ing created by air conditioners, elevators, refrigerators, and so on. The SurgeArrest Rackmount filters out EMI/RFI (electromagnetic and radio frequency interference) noise with components whose electrical resistance is very high at radio frequencies. EMI/RFI noise is com­monly created by the same activ ity, which produces surges, and can also be caused by nearby radio transmitters.
Important Safety, Grounding and Installation Instructions
Before installing the unit, ensure you have read and understand the following safety instructions:
The SurgeArrest Rac kmoun t supressor is int ended for in door use only. Do not install this product where it is exposed to excessive moisture or heat.
Never install any wiring or products during a lightning storm.
Plug the SurgeArrest Rackmount supressor into a 3-wire, grounded outlet only. If the illuminated, contact a qualified electrician to correct the service wiring.
The SurgeArrest Rackmount is designed to be mounted in a vari­ety of orientations in an equipment rack. Brackets with multiple hole patterns can be easily installed in either a horizontal or verti­cal orientation, as shown in the diagrams below, and to the right.
Do not use extension cords or adapters with this product.
CAUTION: Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and the electrical ser­vice panel.
SITE WIRING FAULT indicator is
ON/OFF ROCKER SWITCH
UNSWITCHED CONVENI ENCE OUTLET
•Two Wire Guides are provided to neatly bundle the line cord s of the equipment being protected. Four Plug P ull-out Guards are provided. Use these to prevent cord s from accidental disconnec­tion from suppressor receptacles, shown in the diagram below.
•The Switch Guard prevents power from acc ide ntally being turned off.
Rack mount ears are included, and are pre-i nstalled for conve­nience. If required, they can be att ached.
•A 15-foot power cord provides additional convenience in posi- tioning the rack system into place.
Operation
The Site Wiring Fault Indicator (red) will illuminate if the building wiring is faulty, regardless of the position of the On/Off Switch. This indicator signals ei ther: missing ground wiring, the hot and neutral wires are reversed, or the ne utral circuit is overloaded. If this indic ator is illuminated, a qualified electrician should be called to correct the service wiring. When Sur ge Arrest Rack mount is fully loaded , the S ite Wiring Fault indicator may flicker - this is normal and may not be indicative of a fault. Even if equipment appears to operate normally, faulty wiring could result in a shock hazard that can prevent the SurgeArrest Rackmoun t from providing rated surge and noise sup­pression.
The Protection Working LED (green) indicator is normally illumi-
Note:
nated when the switch is activated. The li g ht is off when SurgeAr rest Rack­mount has disconnected itsel f from th e utility due to a sustained ultra high energy surge, such as a direct lightning str ike . If you observe that this LED indicator is off, first check the Circuit breaker and On/Off Switch to make sure that the suppressor is on and receiving power. If the Protection Working LED still does not light, return the unit to APC to be repaired or replaced.
The Circuit Breaker is tripped when the button pops out. This indi­cates the suppressor is overloaded, and at least one supported device needs to be unplugged. The circuit breaker is rated to trip at the same overload point as most home and office utility service branch protec­tors (15 Amps).
On/Off Control regulates power to the eight switched outlets, and
The can be used as a system master switch to all nine switched outlets.
Mounting Procedures
Study the diagrams on this page for rack mounting options. All required brackets and screws are provided.
(9) SWITCHED OUTLETS
REAR VIEW
15A POWER CORD
SurgeArrest Rackmount -- Front and Rear Views
RACKMOUNT SURGE ARREST
VERTICAL MOUNTING OPTIONS
UNIVERSAL MOUNTING
22.50" MAX
SSEMBLY MOVEMENT BACKWARDS UP TO 2''
VERTICAL EIA RAIL MOUNTING
(PERSPECTIVE ILLUSTRATES LOOKING
990-2466A 11/09
RACKMOUNT SURGEARREST
VERTICAL EIA RAIL
BRACKET
IF SO DESIRED, ASSEMBLY CAN BE ROTATED 180? SO OUTLETS FACE UP
o
HORIZONTAL MOUNTING OPTIONS
RACKMOUNT SURGEARREST
REVERSE MOUNTING OPTIONS
ASSEM B LY MOVEME NT IS FORWARD OR BACKWARD UP TO 2"
UNIVERSAL MOUNTING
American Power Conversion
Limited Factory Warranty
Surge Products Factory Warranty
Terms of Warranty
American Power Conversion warrants its products to be free from defects in materials and workmanship under normal use based on the following terms:
Product Region Warranty Period
Protect Net D ata
Line Surge
Protectors
Surge Arrest Surge
Protectors
APC’s obligation under this warranty is limited to repairing or replacing, at its sole descretion, any such defective products . This warranty does not ap ply to equipment that h a s been damaged by accident, negligence or misapplication, or has been altered or modi­fied in any way. Repair or replacement of a defe ctive product or part thereof does not extend the original warranty period. Any parts furnished under this warranty may be new or factory remanufac­tured. T o obtain se rvice und er warranty you must obtain a Returne d Material Authorization (RMA) number from APC or an APC Service Center. The product must be returned with an RMA num­ber, with transportation charges prepaid to and from APC or and APC Service Center, and only to the purchaser.
Non-transferable Warranty This warranty applies only to the original purchaser who must have properly registered the product. Th e product may be registered at warranty.apc.com Exclusions APC shall not be liable under the warranty if its testing and exami­nation disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation or testing. Further APC shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair, installa­tion, startup by non-APC designated personnel, a change in location or operating use, exposure to the element s, Acts of God, fire, theft, or installation contrary to APC recommendations or specifications, or in any event if the APC serial number has been altered, defaced, or removed, or any other cause beyond the range of the intended use.
USA, Canada, European
Union, UK, Australia, New
Zealand
All other Regions 10 Years
USA, Canada, European
Union, UK, Australia, New
Zealand
All other Regions 5 Years
.
Lifetime of O riginal
Purchaser
Lifetime of O riginal
Purchaser
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERA­TION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREE­MENT OR IN CONNECTION HEREWITH. APC DIS­CLAIMS ALL IMPLIED WARRANTIES OF MERCHANT ABI LITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. APC EXPRESS WAR­RANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, APC RENDERING OF TECHNICAL OR OTHER AD V ICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRAN­TIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC SOLE LIABILITY AND PURCHASER’S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. APC WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL APC, ITS OFFICERS, DIREC­TORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUEN­TIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PROD­UCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSI­BILITY OF SUCH DAMAGES. SPECIFICALLY, APC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROF­ITS OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE.
NO SALESMAN, EMPLOYEE, OR AGENT OF APC IS AUTHORIZ ED TO ADD TO OR VARY THE TERMS OF THIS WARANTY. WARRANTY TERMS MAY BE MODI­FIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL DEPARTMENT.
Warr an t y Cl aim s
Customers with warranty claims issues may access the APC world­wide customer support network through the APC Web site: support.apc.com
. Select your country from the co unt ry selection pull-down menu. Open the support tab at the top of the Web page to obtain contact information for customer support in your region.
990-2466A 11/09
Loading...