Back-UPS® Pro Battery Pack
Installation and Operation
Installation
bu149a
Battery Maintenance and Storage Guidelines
Please follow these Guidelines to get the best performance
possible from your UPS.
1. Keep the UPS in a cool location.
2. Turn the UPS OFF when connected equipment is not in
use. If the connected equipment will not be used for a long
period of time, turn the UPS OFF to preserve the bat tery.
3. Manage UPS Shut down in regions having frequent
outages. Promptly save your file s and shut down your
computer at the onset of a power outage to preserve battery
life and reduce rechar ge time. If the UPS was supplied with
a computer cable, you can automate this process by down
loading and configuring Power Chute
®
software .
4. Replace the battery after extended storage. If it is not
possible to rechar ge the stored UPS battery following 6
months of storage, it is recommended to purchase a genuine
APC Replacement Battery Cartridge (APCRBC) to
maintain optimal perf ormance of the UPS. Note: AP C's UPS
inventory policy is to recharge the UPS before storage
causes loss of run time performance.
5. Battery wea r and warranty. Eventually, the battery will
become worn from use and require replacement. Normal
battery wear is not covered by the Limited Warranty.
Contact APC to purchase a genuine APC Replacement
Battery Cartridge (APCRBC).
Contact Information
Technical Support http://www.apc.com/support
Worldwide +1 800-555-2725
bu0151a
Specifications
Model BR24BPG
Battery Voltage 24 Vdc (nominal)
Typical Recharge Time 24 hours
o
Operating Te m p erature 0
Storag e Temperature -5
Operating / Storage
Relative Humidity
Size (H x W x D) 30.1 x 1 1.2 x 38.2 cm
Weight 13.4 kg (29.5 lb)
Shipping Weight 14.6 kg (32.2 lb)
to 40oC (32o to 104oF)
o
to 45oC (23o to 113oF)
0 to 95% non-condensing
(11 .9 x 4.4 x 15 in)
Limited Warranty
The standard warrant y is three (3) years f rom the date of
purchase. (Valid in U.S., Canada, and European
Community only. For all other regions, the standard
warranty is two (2) years from the date of purchase ).
APC’s sta ndard procedure is to replace the original unit
with a factory recondition ed unit. Customers who must
have the original unit back due to the assig nment of
asset tags and set depreciation schedules must declare
such a need at first contact with an APC Technical
Support representat ive. APC will ship the replacement
unit once the defective unit has been rec eived by the
repair department, or cross-ship upon the receipt of a
valid credit card number. The customer pays for
shipping the unit to APC. APC pays ground freight
transportation costs to ship the replacement unit to the
customer.