Residential Gas Water Heaters
®
STANDARD VENT
FEATURES
SIDE-MOUNTED RECIRCULATING TAPS
For installation with combination space heating/potable water heating applications
(such as ProMax XL, Heat Exchanger) or any system requiring a recirculating hot water loop.
DYNACLEAN™ II AUTOMATIC SEDIMENT-CLEANING SYSTEM
Specially designed dip tube directs incoming cold water to create turbulence in the tank,
to reduce lime and sediment buildup. DynaClean™ II helps maximize tank life, maintain
high energy-efficiency and increases hot water output. Made from long-lasting PEX
cross-linked polymer.
200/201 Series
GREEN CHOICE® GAS BURNER
Patented “Eco-Friendly” design reduces NOx emissions by up to 33%, and meets less than 40 ng/j
requirement for low NOx emissions.
COREGARD™ ANODE RODS
A. O. Smith’s exclusive aluminum anodes have a stainless steel core, protects tank against
corrosion longer versus ordinary mild steel anodes.
PUSH-BUTTON PIEZO IGNITOR
Makes lighting pilot fast and easy with one-hand push-button spark ignition.
Standard on C3 Technology™ models.
HEAT TRAP NIPPLES
Standard on all models.
DURABLE TAMPER-RESISTANT BRASS DRAIN VALVE
THICK CFC-FREE FOAM INSULATION
Improves efficiency.
BLUE DIAMOND® GLASS COATING
Provides superior corrosion resistance compared to industry-standard glass lining.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
Top-mounted T&P relief valve available as an option.
FVIR COMPLIANT
See other side.
CODE COMPLIANCE
UBC, CEC, SBCC, CABO, HUD, BOCA National Codes. Meets or exceeds the thermal efficiency and
standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA
90.1. Meets or exceeds the Federal Energy Efficency Standards effective January 20, 2004,
according to the National Appliance Energy Conservation Act (NAECA) of 1992.
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANSI Z21.10.1 - CSA 4.1 Standards governing storage-type water heaters.
10-YEAR LIMITED TANK AND PARTS WARRANTY
For complete information, consult written warranty or A. O. Smith Water Products Company.
September 2010R
®
Page 1 of 2
AOSRG46100
STANDARD VENT
Residential Gas Water Heaters
®
MODEL
NUMBER
FIRST
HOUR
RATING
GALLONS
ENERGY
FACTOR
GALLON
CAPACITY
BTU
INPUT
PER HOUR
NATURAL
BTU
OUTPUT
PER HOUR
†
NATURAL
RECOVERY
90ºF RISE
GALLONS
PER HOUR
R
VALUE
A B C D E F G H
DIMENSIONS IN INCHES
DRAFT
HOOD
OUTLET
APPROXIMATE
SHIPPING
WEIGHT
(LBS)
10-YEAR LIMITED TANK AND PARTS WARRANTY
XGV-40L 70 .63 40 40,000 30,400 41 16 61-3/4
58-1/4
20 13 8 51-3/4 14-1/4 51-3/4 3 or 4 150
XGV-50L 88 .62 50 40,000 30,400 41 16 61 57-1/4 22 13 8 50-1/2 14-1/4 50-1/2 3 or 4 165
Recovery capacity based on actual performance tests.
† Propane Gas – XGV-40L: 36,000 BTU; XGV-50L: 37,000 BTU
Models are ENERGY STAR® qualified.
Flammable Vapor Ignition
Resistant Water Heaters
A. O. Smith FVIR design meets or exceeds the American National Standards
Institute standards (ANSI Z21.10.1 - CSA 4.1 Standards) that deal with the accidental or unintended
ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor
built into the water heater base. In addition, a thermal cutoff (TCO) device, is
designed to shut off gas flow to the burner and pilot if poor combustion is detected.
HOT
CONNECTION
T&P VALVE
1/2" GAS
CONNECTION
E
C
D
ANODE ROD*
COLD
CONNECTION
H
F
G
A
B
*Location for optional top-mounted
T&P Valve if ordered from factory.
Maximum hydrostatic working
pressure: 150 psi
If flammable vapors accidentally enter the
combustion chamber, the arrestor is designed
so flames burn off the top surface and can not
escape down through the arrestor.
A. Industry standard thermocouple
B. Large View Port for easy burner inspection
0
C. 360
combustion air filter
D. Thermal Cutoff (TCO) with manual reset
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
September
2010R
www.hotwater.com
Page 2 of 2
AOSRG46100