Commercial Semi-Instantaneous Water Heaters
FEATURES
A. O. S mith’s HWI mo dels are available for operation with steam or boiler water
as the ene rgy source. T hey are factory assembled with co mponents sized, piped
and checked at the fa ctory before shipment. HWI models are all space saving
ver tical models.
INSUL ATION AND JACKETING - T he HWI systems will be insulated with
fiberglas s to an R value of 12.5 and enclosed in a baked enamel ja cket.
CODE LISTING
ASME “U” code 3/4” diameter copper tube heat exchang er.
INTEGRAL PUMP
pump.
STEAM UNITS
auxiliary steam traps, inlet and auxiliar y strainers, steam pressure gauge with
siphon , vacuum breaker and air vent.
BOILER UNITS
water temperature gauge.
CONTROL FEATURES
n
SINGLE POINT WIRING
Single 120V connection, controls including integral circulation
n
ON/OFF SWITCH
Allows local on/off for service
n
TEMPERATURE READOUT
LED readout of water temperature
n
PID TEMPERATURE CONTROL
Modulates electrical control valve
n
HIGH TEMPERATURE LIMIT
Closes main valve under over temperature condition
n
REMOTE TEMPERATURE SIGNAL
n
2-WIRE RS485 COMMUNICATION (MODBUS or ASCII)
- The system will employ an A SME”U” code shell. fitted with an
- The HWI system will employ an integral bronze circulator
- Steam trim consists of temperature control valve, inlet and
- Boiler water trim includes temperature control valve and boiler
HWI Models
LIMITED WARRANTY OUTLINES
If the shell should leak any time during the first five years, under the terms of the
warranty A. O. Smith will repair or replace the shell. Installation, labor, handling and
local delivery extra.
THE COIL HAS A ONE YEA R LIMITED WARRANTY.
NOTE: THIS OU TLINE IS NOT A WA RR ANTY. For complete information, consult the
written warrant y or A. O. Smith.
U
Revised November 2012
Page 1 of 8
AOSCG40100
Commercial Semi-Instantaneous Water Heaters
TO SPECIFY HWI SERIES PACKAGE WATER HEATER:
1. Determine what t ype of heating medium will be used; steam or b oiler water.
• If STEAM - Determine pressure in coil.
• If BOILER WATER - Determine available boiler water temperature.
2. From the recovery table, obtain the required GPH capa cit y and temperature rise.
Selecting heating coil size.
3. Decide whether single or double wall coil is required.
SE LE CT YOUR M OD EL
ST YL E CO IL M OD EL TY PE
CAPACITY CHARTS:
Temp Range Heater Model
40°F
To
120°F
40°F
To
140°F
HWI-W 0848
HWI-W 1048
HWI-W 1248
HWI-W 1448
HWI-W 1648
HWI-W 1848
HWI-W 0848
HWI-W 1048
HWI-W 1248
HWI-W 1448
HWI-W 1648
HWI-W 1848
HWI
CHOS EN F ROM TABLE S TO
DETE RMIN E CODE SI ZE
ST EA M = S WATE R = W
0 8 4 8S E15 D
Boiler Water 180°F - 160°F
DOM water
flow GPM
11
19
26
35
47
59
7
12
17
22
30
39
DOUB LE
WALL = D
SING LE
WALL = S
ST EA M PRE SS UR E
WATER TEMPERATURE
Boiler Water
flow GPM
45
77
106
143
192
241
35
61
86
112
152
198
BTU/HR Passes
438,000
756,000
1,035,000
1,393,000
1,870,000
2,347,000
347,000
596,000
844,000
1,092,000
1,489,000
1,936,000
2
2
2
2
2
2
4
4
4
4
4
4
Boiler Water 190°F - 170°F
Temp Range Heater Model
HWI-W 0848
40°F
To
120°F
40°F
To
140°F
For Technical Information and Automated Fax Service, call 800-527-1953. A . O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised November 2012
HWI-W 1048
HWI-W 1248
HWI-W 1448
HWI-W 1648
HWI-W 1848
HWI-W 0848
HWI-W 1048
HWI-W 1248
HWI-W 1448
HWI-W 1648
HWI-W 1848
DOM water
flow GPM
13
22
31
41
55
68
8
14
19
26
35
44
Boiler Water
flow GPM
53
90
127
167
225
278
41
71
97
133
178
224
BTU/HR Passes
517,000
875,000
1,234,000
1,631,000
2,189,000
2,706,000
397,000
695,000
943,000
1,291,000
1,738,000
2,185,000
www.hotwater.com
2
2
2
2
2
2
2
2
2
2
2
2
Page 2 of 8
AOSCG40100
CAPACITY CHARTS (Continued):
Commercial Semi-Instantaneous Water Heaters
Temp Range Heater Model
40°F
To
120°F
40°F
To
140°F
Steam pressure in lines/steam pressure in tubes.
*
Temp Range Heater Model
40°F
To
120°F
40°F
To
140°F
Steam pressure in lines/steam pressure in tubes.
*
HWI-S 0648 05
HWI-S 0848 05
HWI-S 1048 05
HWI-S 1248 05
HWI-S 1448 05
HWI-S 1648 05
HWI-S 0648 05
HWI-S 0848 05
HWI-S 1048 05
HWI-S 1248 05
HWI-S 1448 05
HWI-S 1648 05
HWI-S 0648 10
HWI-S 0848 10
HWI-S 1048
HWI-S 1248
HWI-S 1448
HWI-S 1648
HWI-S 0648 10
HWI-S 0848 10
HWI-S 1048
HWI-S 1248
HWI-S 1448
HWI-S 1648
10
10
10
10
10
10
10
10
Steam 5/2*
DOM water flow GPM Ibs /HR
11
20
33
47
61
82
7
14
23
34
43
58
Steam 10/5*
DOM water flow GPM Ibs /HR
11
21
35
51
66
87
8
15
25
36
48
63
617
778
1285
1848
2369
3185
363
686
1130
1648
2096
2821
459
846
1373
2030
2649
3472
410
755
1250
1807
2380
3119
Temp Range Heater Model
HWI-S 0648 15
40°F
To
120°F
40°F
To
140°F
Steam pressure in lines/steam pressure in tubes.
*
For Technical Information and Automated Fax Service, call 800-527-1953. A . O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised November 2012
HWI-S 0848 15
HWI-S 1048
HWI-S 1248
HWI-S 1448
HWI-S 1648
HWI-S 0648 15
HWI-S 0848 15
HWI-S 1048
HWI-S 1248
HWI-S 1448
HWI-S 1648
15
15
15
15
15
15
15
15
Steam 15/10*
DOM water flow GPM Ibs /HR
12
23
38
56
73
96
9
17
28
40
53
69
512
946
1546
2268
2968
3889
467
861
1420
2045
2691
3510
www.hotwater.com
Page 3 of 8
AOSCG40100