A. O. Smith GCN-100 User Manual

Residential Gas Water Heaters
PROMAX® ULTRA-LOW NOX HIGH RECOVERY
FEATURES
FULLY AUTOMATIC CONTROLS WITH SAFETY SHUTOFF — Accurate, dependable control system requires no electric connections. Fixed automatic gas shutoff device for added safety.
HEAVY GAUGE STEEL JACKET — Finished with baked enamel over bonderized undercoat.
GLASSLINED TANK — Maximizes tank life.
FOAM INSULATION — Saves fuel, helps reduce standby heat loss.
ULTRA-LOW NOx Emissions — Complies with SCAQMD Rule 1146.2 and other
Air Quality Management Districts with similar requirements of 14 ng/j or 20 ppm.
EASY-TO-INSTALL — Completely factory-assembled. Only gas, water and vent connections need to be made. All connections are located in front and top of heaters for ease-of-installation and service.
GCN-100
DRAFT DIVERTER — Low profile diverter furnished as standard equipment.
MAXIMUM WORKING PRESSURE — 150 psi.
MAXIMUM GAS INLET PRESSURE — 14” W.C.
ANODIC PROTECTION — Coregard™ Anode Rod.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
SIX YEAR LIMITED TANK AND PARTS WARRANTY — For complete warranty
information, consult written warranty or contact A. O. Smith.
Revised June 2013
Page 1 of 2
AOSRG45820
DRAIN VALV E
K
HOT WATER
OUTLET
J
A
Residential Gas Water Heaters
HOT
TOP VIEW
H
L
COLD
C
F
D
K
COLD WATER
INLET
TEMPERATURE AND PRESSURE RELIEF VALVE
G
B
DRAIN VALVE
E
M
GAS INLET
FRONT VIEW
BTU
MODEL
GCN-100 100 75,100 60,080 81 70-1/2 66-1/2 30-15/16 27-3/4 15-3/16 4 15-3/4 16 1-1/4 1-1/4 1/2 11-15/16 350
Water heater(s) shall be Model ________________ as manufactured by A. O. Smith or an approved equal. Water heater(s) shall be of glasslined design, equipped to burn __________ gas and design certified by UL and shall be approved by the National Sanitation Foundation (with optional leg kit). Heaters must meet all applicable energy codes and comply with ultra-low NOx emissions of 14 ng/j or 20 ppm. Heaters shall have an input rating of _____ BTU/H and a recovery capacity of _____ GPH at a temperature rise of 90°F with a storage capacity of _____ gallons. Heater shall have a working pressure of 150 psi. Heater(s) shall be provided with an automatic gas shutoff device and safety shutoff in event pilot flame is extinguished; a gas pressure regulator set for the type of gas supplied; an approved draft diverter, and extruded anode rod rigidly supported for cathodic protection. A CSA Certified and ASME Rated T&P Relief Valve shall be furnished and installed by the manufacturer. The tank shall be foam insulated. The outer jacket shall have a baked enamel finish over a bonderized undercoating. Fully illustrated instruction manual. All internal surfaces of the heater(s) exposed to water shall be glasslined with an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature range of 1400° to 1600°F. Heater tank shall have a six year limited tank and parts warranty against corrosion and tank failure due to sediment build-up as outlined in the written warranty. Heater(s) shall be design certified by UL for operation of the heater in a closed system where thermal expansion has not been compensated for with a properly sized expansion tank will void the warranty.
GALLON
CAPACITY
INPUT
PER
HOUR
BTU
OUTPUT
PER
HOUR
RECOVERY
90°F RISE GALLONS
PER HOUR
DIMENSIONS IN INCHES
SUGGESTED SPECIFICATION
APPROX.
SHIPPING
WEIGHT
(LBS.)ABC DEFGHJKLM
For Technical Information and Automated Fax Service, call 800-527-1953. A. O . Smith Corporation reserves the right to make product changes or improvements without prior notice.
www.hotwater.com
Page 2 of 2
AOSRG45820