Residential Gas Water Heaters
®
HIGH EFFICIENCY RESIDENTIAL MODELS
FEATURES
ENERGY STAR
■ Meets ENERGY STAR requirements for the .67 EF tier II efficiency increase
initiated September 1, 2010 and is eligible for most utility rebate programs based
on Energy Factor (EF) Ratings.
AUTOMATIC FLUE DAMPER
■ Increases efficiency as it auto-matically opens and closes to reduce heat loss in the
standby mode.
ELECTRONIC GAS CONTROL
■ Intelligent control logic provides enhanced operating paramet
differentials for precise sensing and faster heating response to optimize performance.
DIAGNOSTICS
■ The electronic gas control incorporates an LED status indicator that monitors system
operation and service diagnostics.
ELECTRONIC IGNITION
■ Heater operates with an automatic pilot relight system that shuts off the pilot during
stand-by modes to reduce gas consumption and eliminates nuisance pilot outage issues
associated with standing pilot models.
POWER REQUIREMENTS
■ Plugs into standard 110/120v outlet (10 foot power cord included).
DYNACLEAN™ DIFFUSER DIP TUBE
■ Helps reduce lime and sediment buildup, maximize hot water output. Made from
long-lasting PEX cross-linked polymer.
GREEN CHOICE
■ Patented “Eco-Friendly” design reduces Low NOx emissions by up to 33% and meets
less than 40 ng/j requirements for Low NOx.
COREGARD™ ANODE ROD
■ An A. O. Smith exclusive. Anode has stainless steel core, protects tank against corrosion
longer than ordinary steel anodes.
DURABLE, BRASS TAMPER-RESISTANT DRAIN VALVE
BLUE DIAMOND® GLASS COATING
■ A. O. Smith BLUE DIAMOND
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
■ Top-mounted T&P Relief Valve available as option on all models.
CODE COMPLIANCE
■ UBC, CEC, SBCC, HUD and BOCA National Codes. Meets the thermal efficiency and
standby loss requirements of the U. S. Department of
current edition of ASHRAE/IESNA 90.1. Meets the Federal Energy
Efficiency Standards effective January 20, 2004, according to the National
Appliance Energy Conservation Act (NAECA) of 1992.
DESIGN-CERTIFIED BY CSA INTERNATIONAL
■ According to ANSI Z21.10.1 - 4.1 CSA Standards governing storage-type water heaters.
®
QUALIFIED
®
GAS BURNER
ers and tighter
®
process provides superior protection against corrosion
Energy and
®
FLAMMABLE VAPOR IGNITION RESISTANT COMPLIANT DESIGN
6-YEAR LIMITED TANK AND PARTS WARRANTY
■ For complete information, consult written war
Revised April 2013
rant
Page 1 of 2
AOSRG45250
®
Residential Gas Water Heaters
RESIDENTIAL GAS MODELS
FIRST
ENERGY
MODEL
NUMBER
SERIES
HOUR
RATING
GALLONS
FACTOR
(EF)
GALLON
CAPACITY
TALL MODELS
GCF-40 100 67
GCF-50 100 81
.67 40 40,000 42 2 64-1/4 58-1/4 20 13 8 51-3/4 3 or 4 152
.67 50 40,000 42 2 63-1/2 57-1/4 22 13 8 50-1/4 3 or 4 167
SHORT MODEL
GCFL-40 100 67
GCFL-50 100 86
Recovery capacity based on actual performance tests.
Water Connections - 3/4” on all models.
External heat trap nipples are factory-installed on all models
Order SMR S45 for Top T&P - Example GCF-40 S45
All models are ENERGY STAR
A
ll models are certified from sea level to 10,100 ft. elevations
*Propane (LP) gas - 37,000 BTU input for 50-gallon tall models and 36,000 BTU for 40-gallon models
50-gallon short model, not available in LP gas
®
qualified.
.67 40 40,000 42 2 54 47-3/4 22 13 8 41 3 or 4 149
.67 50 40,000 42 2
BTU
INPUT
PER
HOUR
NATURAL*
ANODE ROD*
RECOVERY
90°F RISE
GALLONS
PER HOUR
FOAM
THICKNESS
(INCHES)
DIMENSIONS IN INCHES
A B C D E F
55-3/4
49-1/2
24
13-1/4
8
42-1/2
DRAFT
HOOD
OUTLET
APPROX.
SHIPPING
WEIGHT
(LBS)
3 or 4 175
HOT
CONNECTION
T&P VALVE
1/2" GAS
CONNECTION
COLD
CONNECTION
E
C
A
B
F
D
* Location for optional top-mounted T&P Valve if ordered from factory.
Maximum Hydrostatic Working Pressure: 150 PSI.
For Technical Information call 1-800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised April 2013
Page 2 of 2
www.hotwater.com AOSRG45250