A. O. Smith FCG-100 User Manual

Residential Gas Water Heaters
®
HIGHEST RECOVERIES AND FIRST HOUR RATINGS
Capacity/input combinations up to 98 gallons/75,100 BTUs produce recoveries up to 81 gallons per hour, with deliverable hot water up to 150 gallons.
DYNACLEAN™ DIFFUSER DIP TUBE
Helps reduce lime and sediment buildup, maximizes hot water output. Made from long lasting PEX cross-linked polymer.
GREEN CHOICE® GAS BURNER
Pateneted “Eco-Friendly” design reduces NOx emissions by up to 33% and complies with less than 40 ng/j requirements for NOx emissions.
COREGARD™ ANODE ROD
A.O. Smith’s exlusive aluminum anode has a stainless steel core, protects tank against corrosion.
HEAT TRAP NIPPLES
Factory-installed on most models
PUSH-BUTTON PIEZO IGNITOR
Makes lighting pilot fast and easy with one-hand push-button spark ignition.
DURABLE, TAMPER-RESISTANT BRASS DRAIN VALVE
BLUE DIAMOND® GLASS COATING
Provides superior corrosion resistance compared to industry-standard glass lining.
THICK, “ENVIRONMENTALLY-FRIENDLY” NON CFC-FOAM INSULATION Improves efficiency.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
Top-mounted T&P relief valve available as option.
CODE COMPLIANCE
Meets UBC, CEC, SBCC, HUD and BOCA National Codes. Meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 and meets the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992.
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANSI Z21.10.1 - CSA 4.1 standards governing storage-type water heaters.
FLAMMABLE VAPOR IGNITION RESISTANT COMPLIANT DESIGN
See other side.
6-YEAR LIMITED TANK AND PARTS WARRANTY
For complete information, consult written
Series 100/101
®
Revised November 2012
Low Lead Content
Page 1 of 2
AOSRG45400
®
Residential Gas Water Heaters
MODEL
NUMBER
SERIES
FIRST HOUR
RATING
GALLON
CAPACITY
(GPH)
GCVT-40
GCVT-50
GCVX-50
GCV-65
FCG-75*
FCG-100*
300
300
100
100
300
300
Recovery capacity based on actual performance tests. Water Connections – 1" on 75-gallon model, 1-1/4" on 100-gallon model, 3⁄4" on all other models. * Not equipped with FVIR Technology. 75 and 100-gallon models have factory-installed (non-heat trap) nipples, 75-gallon model has 80% efficiency, 998 BTU/hr. standby loss; 100-gallon model has 80% efficiency, 1146 BTU/hr. standby loss.
† Propane Gas – GCVT-40: 45,000 BTU input; GCVT-50: 45,000 BTU input; GCVX-50: 55,000 BTU input; GCV-65: 62,500 BTU input.
For 10-Year Tank and 6-Year Parts Warranty, change “G” to “X” in Model Number (example: XCVT-40), or change “F” to “P” in model number (example: PCG-75). The FVIR Series 100 models are certified from sea level to 7,700 ft. elevations. The FVIR Series 300 models are certified from sea level to 10,100 ft. elevations. The 75 & 100-gallon models are certified to 7,700 ft. elevations.
75 40 51
90 50 51
93 50 67
116 65 67
N/A 74 81
N/A 98 81
RECOVERY
90°F RISE
PER HOUR
ENERGY FACTOR
BTU INPUT
PER HOUR NATURAL
0.60 50,000 16
0.58
0.58
0.57
50,000 8
65,000 16
65,000
N/A 75,100 16
N/A
75,100 10
R
VALUE
A B C D E F
61-3/4 58-1/4 20 13 8 51-3/4
60-3/4 57 20 13 8 50-1/4
63-7/8 59-1/2 22 15-1/2 8 54-1/8
65 60 24 15-1/2 8 54-1/4
16
61 57 26-1/2 14-3/4 16 50-1/4
68-1/2 65 27-3/4 15-3/16 16 57-3/8
Flammable Vapor Ignition Resistant FVIR
DIMENSIONS (INCHES)
HOT CONNECTION
DRAFT
HOOD
OUTLET
4
4
4
4
4
4
Water Heaters
FVIR design meets American National Standards Institute standards
(ANSI Z21.10.1 - 4.1 CSA Standards) that deal with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
FVIR gas water heaters feature a sealed combustion chamber with air intake screen and a fireproof Corderite flame arrestor built into the water heater base. In addition, a thermal cutoff (TCO) device, integral with the thermocouple, is designed to shut off gas flow to the burner and pilot if poor combustion is detected.
E
C
APPROX.
SHIPPING
WEIGHT
(LBS)
138
153
195
215
275
350
ANODE ROD*
COLD CONNECTION
If flammable vapors accidentally enter the combustion chamber, the Corderite flame arrestor is designed so flames burn off the top surface and cannot escape down through the arrestor.
A. Easy-to-light
piezo ignitor
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Revised November 2012
B. View port for easy
burner inspection inside sealed combustion chamber
www.hotwater.com
T&P VALVE
1/2" GAS CONNECTION
D
*Location for optional top-mounted T&P Valve if ordered from factory.
(FVIR models only)
A
B
F
Page 2 of 2
AOSRG45400