A.O. Smith EQ - EQB User Manual

Page 1
Innovation has a name.
EQ / EQB
Gas-fi red residential / light commercial water heater
EQ - 115/155/200/280/380 EQB - 115/155/200
Atmospheric water heater with thermal fl ue spillage protection
• Suitable for natural or LP gas • Optional ancillaries: Unvented kits • Destratifi cation pump kit • Powered anode
• Time clock kit • Flue fan kit • Solenoid valve kit
Page 2
EQ / EQB
Technical specifications
EQ 115
EQ 155
EQ 200
EQ 280
EQ 380
EQB 115
EQB 155
Gas data natural gas 2H (G20)
Input* kW 9.3 11.3 18.3 23.1 27.4 9.3 11.3 18.3 Output kW 7.4 9.0 14.0 16.0 19.2 7.4 9.0 14.0 Inlet pressure mbar 20 20 20 20 20 20 20 20 Burner pressure mbar 12.5 12.5 10.5 11.5 10.0 12.5 12.5 10.5 Gas consumption** m3/h 0.9 1.1 1.7 2.2 2.6 0.9 1.1 1.7 Diameter pilot orifice mm 2 x 0.27 2 x 0.27 2 x 0.27 2 x 0.27 2 x 0.27 2 x 0.27 2 x 0.27 2 x 0.27 Diameter main orifice mm 2.35 2.60 3.5 3.9 4.5 2.35 2.60 3.5
Max. ue gas temperature °C 255 200 160 255 290 255 200 160
Gas data butane 3+ (G30)
Input* kW 10.1 12.2 17.6 21.8 29.6 10.1 12.2 17.6 Output kW 8.2 9.9 13.7 15.5 21.2 8.2 9.9 13.7 Inlet pressure mbar 30 30 30 30 30 30 30 30 Burner pressure mbar - - - - - - - ­Gas consumption** kg/h 0.7 0.9 1.3 1.6 2.2 0.7 0.9 1.3 Diameter pilot orifice mm 0.22 0.22 0.22 2 x 0.16 2 x 0.16 0.22 0.22 0.22 Diameter main orifice mm 1.40 1.50 1.95 2.20 2.50 1.40 1.60 1.95
Max. ue gas temperature °C 255 200 160 255 290 255 200 160
Gas data propane 3+ (G31)
Input* kW 9.8 11.8 17.2 20.9 26.6 9.3 11.7 17.6 Output kW 7.9 9.6 13.4 14.8 19.0 7.6 9.5 13.7 Inlet pressure mbar 37 37 37 37 37 37 37 37 Burner pressure mbar - - - - - - - ­Gas consumption** kg/h 0.7 0.8 1.2 1.5 1.9 0.7 0.8 1.2 Diameter pilot orifice mm 0.22 0.22 0.22 2 x 0.16 2 x 0.16 0.22 0.22 0.22 Diameter main orifice mm 1.40 1.50 1.95 2.20 2.50 1.40 1.60 1.95
Max. ue gas temperature °C 255 200 160 255 290 255 200 160
Draw-off capacity
Storage capacity l 109 144 181 265 355 109 144 181
Max. temperature setting °C 71 71 71 71 71 81 81 81
30 min. T=44°C l 169 216 296 394 508 169 216 296 60 min. T=44°C l 241 304 433 550 695 241 304 433 90 min. T=44°C l 314 392 569 707 883 314 392 569 120 min. T=44°C l 386 480 706 864 1070 386 480 706 Continuous T=44°C l/h 144 175 273 313 375 144 175 273 Heating-up time T=44°C min. 45 49 40 51 57 45 49 40 30 min. T=50°C l 149 190 260 347 447 149 191 260 60 min. T=50°C l 212 268 381 484 612 212 268 381 90 min. T=50°C l 276 345 501 622 777 276 345 501 120 min. T=50°C l 339 422 621 760 942 339 422 621 Continuous T=50°C l/h 127 154 241 275 330 127 154 241 Heating-up time T=50°C min. 51 56 45 58 65 51 56 45 30 min. T=55°C l 135 173 237 315 406 135 173 237 60 min. T=55°C l 193 243 346 440 556 193 243 346 90 min. T=55°C l 251 313 455 565 706 251 313 455 120 min. T=55°C l 309 384 565 691 856 309 384 565 Continuous T=55°C l/h 116 140 219 250 300 116 140 219 Heating-up time T=55°C min. 57 62 50 63 71 57 62 50
General
Anodes - 1 1 Maximum working pressure bar 8 8 Maximum weight kg 156 196 256 382 499 156 196 256
EQB 200
Shipping data
Weight empty kg 47 52 75 117 144 47 52 75 Weight incl. packaging kg 51 57 81 135 162 51 57 81 Width packaging mm 530 580 570 780 780 530 580 570 Height packaging mm 1140 1250 1580 1640 1830 1140 1250 1580 Depth packaging mm 570 630 650 870 870 570 630 650
* Gas data on gross value
** Gas consumption at 15°C and 1013.25 mbar
Page 3
EQ / EQB
EQ / EQB
Dimensions
A 1280 1370 1600 1670 1585 1780
B 1120 1210 1440 1540 1450 1640
D 465 515 515 515 645 675
E 545 595 595 605 735 765
G 80 80 100 100 130 130
K 325 325 325 380 375 375
M 1180 1270 1500 1590 1505 1685
N 1180 1270 1500 1590 1505 1685
R 230 230 230 255 285 285
S 945 1030 1265 1380 1280 1460
1 Cold water 3/4 - 14 NPT
(EQ 280: 1 -11.5 NPT) (EQ 380: 1 1/4 - 11.5 NPT)
2 Hot water 3/4 - 14 NPT
(EQ 280: 1-11.5 NPT) (EQ 380: 1 1/4 -11.5 NPT)
3 Gas control Rp 1/2 4 Tank drain valve 3/4 - 14 NPT 5 T&P valve 3/4 - 14 NPT
Dimensions in mm. All EQ water heaters receive a fi ve years warranty on the tank and one year on parts. All EQB water heaters have a one year warranty period.
EQ/EQB 115
EQ/EQB 155
EQ 200
EQB 200
EQ 280
EQ 380
Page 4
EQ / EQB
Installation diagrams
EQ / EQB
1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve
A Cold water B Hot water C Return circulation D Gas supply E Overflow pipe H Expansion vent pipe
A.O. Smith unvented system kits utilise combination valves.
An EQ / EQB water heater should be installed in accordance with local standards and ventilation requirements (category B11BS).
Further installation and connection details can be found in the Installation & Commissioning Manual.
For the parts numbers of components please refer to the “Maintenance and accessories” tab.
www.aosmithinternational.com
Data subject to change INT/0808/EQ/02
Terms and conditions apply, please refer to our website.
Loading...