Commercial Gas Water Heaters
POWERED BURNER MODELS
LIGHT-DUTY COMMERCIAL GAS WATER HEATERS
FEATURES
These BTP models are equipped with powered gas, non-forced-draft burners requiring a
negative draft. With 81 gallon storage capacities and inputs from140,000 to as high
as 370,000 BTUs, they are suitable for commercial applications. A. O. Smith provides a FREE
professional start-up that is required on the BTP models.
POWERED GAS BURNER
Electronic flame safeguard control with direct spark ignition
FULLY AUTOMATIC CONTROLS WITH SAFETY SHUTOFF
PERMAGLAS® ULTRA COAT™ GLASSLINING
BAROMETRIC DRAFT DAMPER
HANDHOLE CLEANOUT
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
MODELS
BTP-139/A
through
BTP-370/A
®
80% THERMAL EFFICIENCY
MAXIMUM HYDROSTATIC WORKING PRESSURE: 160 PSI
FACTORY START-UP INCLUDED
FLAME INSPECTION PORT OPENING
MOUNTED ON RUGGED CHANNEL IRON SKIDS
MUST BE INSTALLED ON NON-COMBUSTIBLE SURFACE
CODES AND STANDARDS
CSA4.3 standards governing storage-type water heaters
THREE-YEAR LIMITED TANK WARRANTY
OPTIONS
PG 1 OF 2
Revised June 2012
Revised April 2009
AOSCG10900
CAPACITY, INPUT AND RECOVERY
Model
Number
BTU
Input
Per
Hour
140,000
199,000
270,000
370,000
Gallons or
Litres
U.S. Gallons 81 GPH 0 136 97
U.S. Gallons 81 GPH 0 193 138
U.S. Gallons 81 GPH 0 262 187
U.S. Gallons 81 GPH 0 359 256
Tank
Size
306.6 0.0 514.8 367.1
306.6 0.0 730.4 521.7
306.6 0.0 991 707.8
306.6 0.0 1358 970
Recovery–Gallons
GPH
Per Hour At °F
Temperature Rise
or
LPH
40°F 100°F 140°F
22°C 56°C 78°C
Commercial Gas Water Heaters
Maximum
Amperes
120V, 60
Hz, 1
5
5
5
5
DIMENSIONS AND SHIPPING WEIGHTS
Model Number
Inches
or
Litres
cm 189.9 165.1 67.9 15.2 54.3 70.5 96.5 216.5 1.3 252.7 kg 299.1 kg 3.8 3.8
cm 189.9 165.1 67.9 15.2 54.3 70.5 96.5 216.5 1.3 247.7 kg 288 kg 3.8 3.8
cm 189.9 165.1 67.9 15.2 54.3 70.5 96.5 216.5 1.9 248.6 kg 287.3 kg 3.8 3.8
cm 189.9 165.1 67.9 15.2 54.3 70.5 96.5 216.5 1.9 248.6 kg 287.3 kg 3.8 3.8
A B C D E G H J Gas Standard ASME In Out
74.75 65 6 38 556 lbs. 658 lbs.
65 6 38 545 lbs. 635 lbs
65 6 38 547 lbs. 632 lbs.
65 6 38 547 lbs. 632 lbs.
thgieW gnippihSsnoisnemiD
SUGGESTED SPECIFICATION
a maximum hydrostatic working pressure of 160 PSI. Heater(s) shall meet the thermal efficiency and/ or standby
loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. Water heater(s)
shall have glass-lined tank, protected against elctrolytic corrosion by multiple factory-installed anode rods.
Other standard equipment shall include: 1) Powered gas burner with redundant main gas valves, electronic
T&P relief valve.
minimum shall be provided. A trial for ignition period of 5 seconds, after which if the flame is not proved or lost
during the running cycle, the system will lock out.
warranty.
Revised June 2012
Revised April 2009 PG 2 OF 2
www.hotwater.com
AOSCG10900