Thank you for purchasing this Weather Station, Please read the operating instructions carefully
to familiarize yourself with the features and modes of operation before using the instrument.
Keep the manual for future reference and pass it on with the device, if you pass on the device
to other users.
NOTE: Always remember to use high quality batteries & change them at least once per year.
Package Contents
Carefully unpack and remove the contents:
• 1x Weather station main unit
• 1x Stainless steel mast
• 1x Thermo-hygro sensor
• 1x Rain sensor
• 1x Wind speed sensor
• 1x Wind direction sensor
• 1x Radiation shield
• Mounting screws
• Stainless steel accessory for fixing the mast.
Product overview
1 12 hour air pressure history bar
2 Moon phase
3 Air pressure
9 Alarm
10 Time
11 Day of week
4 Weather forecast
5 Wind direction
6 Wind speed
7 Indoor humidity trend
12 Month (in DM mode) / Date (in MD mode)
13 Date (in DM mode) / Month (in MD mode)
14 Daylight Saving Time
15 Outdoor humidity trend
16 Indoor humidity
17 Outdoor humidity
Press button
Hold button
(A) MODE
Time / Alarm1 / Alarm2 / In
temp alert / Out temp alert mode
switching
Setting the time, setting the alarm time, setting the
temperature alert
(B) DOWN
1. One step back in setting
2. View the rainfall 1hr / 24hr / TOTAL
3. Alarm on / off in alarm mode
Clear the rainfall reading
(C) OUT
View heat index and wind chill
Search for Radio Frequency outdoor sensor
(D) UP
1. One step forward in setting
2. View the Max / Min temperature and
humidity
3. Alarm on / off in alarm mode
Clear the Max / Min temperature and humidity record
(E) IN
View feel like / dew point
RCC reception or clear RCC reception
(F)
SNOOZE/
LIGHT
1. Activates alarm snooze
2. Display black light (when without
power adaptor plugged in)
3. Change display brightness (when
power adaptor plugged in)
Altitude and weather icon setting
18 Outdoor low battery indicator
19 Outdoor temperature
20 Outdoor temperature trend
29 Indoor MAX / MIN
30 Indoor information
31 Indoor temperature alert
32 Rainfall
21 Outdoor temperature alert
22 RF outdoor sensor reception indicator
23 Outdoor MAX / MIN
24 Wind Chill
25 Heat Index
26 Outdoor sensor information
27 Dew point
28 Feel like
33 Living space icon
34 Indoor temperature trend
35 Indoor temperature
36 Indoor low battery indicator
G Power adaptor socket
H Battery compartment
I Stand
Getting Start with Power Supply
Insert Batteries
1. Gently remove the stand downwards and remove battery compartment cover from the main
unit.
2. Insert the batteries, matching the polarities (+/-).
DC Power
1. Put the power cable pass through the hole in the stand, plug the power cable to the
power jack and plug the power adapter into a suitable power outlet.
NOTE It is recommended to insert the battery as a backup power
Remote Sensor
1. Pull away the radiation shield of the thermo-hrgro sensor to reveal the 2 sockets.( for
the wind sensor and rain sensor )
2. Open the thermo-hygro sensor battery door, insert the batteries, matching the
polarities (+/-)
Note: To prevent water from entering the sensor, it is important to make sure the
battery lid closes tightly.
3. Place the sensor near the main unit in order to establish an effective wireless
transmission. Do not place the sensor outside until the transmission have be
confirmed.
4. Observe the LCD screen to see OUT temperature and humidity displayed to confirm
the transmission completed
NOTES:
Every time the power adaptor unplugged and with no batteries inserted, the main unit will
lose all the weather data.
1) Mounting the outdoor sensor onto the stainless steel mast
Attention!! Before assembly the outdoor sensor, the transmission between main unit
and the thermo-hygro sensor must be established
For accurate results, the outdoor sensor mast should be securely mounted onto a horizontal
surface and in an open area away from trees and other coverings where rainfall or wind speed
may be reduced causing inaccurate reading.
The following diagram shows how the parts go together.
2) Mounting the wind speed sensor to the plastic bracket:first check the wind-fan
can rotate freely before fixing. The wind speed sensor should now be mounted onto the
bracket provided to allow the wind to travel around the sensor unhindered from all
directions.Then fix it with bolt and screw. Please follow the below display:
3) Mounting the wind direction sensor to the bracket: first check the wind direction
sensor before fixing, the wind direction sensor should now be mounted onto the bracket
provided to allow the wind to travel around the sensor unhindered from all directions.Then fix it
with bolt and screw. there is one cable from wind speed sensor, please insert it into the socket
under the wind direction sensor.please follow the below display:
Attention!! Please align the “North” indicator sticker with the NORTH direction to enable it to
record accurate reading
4) Mounting the rain sensor to the bracket: there are vertical engraved lines at the
bottom edge of the round cover and the sensor part, you only need adjust the two line into one
position, then turn clockwise, the rain sensor part will be connected well, then fix them with 4
screws and bolt onto the plastic bracket (don’t use only 2 screws) please follow the below
display:
Note: The cover of the Rain Gauge can be removed by rotating in an anti-clockwise
direction. When replacing the cover it will only fit in one position. When you find the
correct position it fits snugly on, and then rotate it clockwise to secure the cover in
place.
It is important that the cover is securely located.
5) Mounting the thermo-hygro sensor to the bracket:
Once the wind sensors and rain sensor are fixed onto the bracket, insert the cables from the
Wind Sensor & the Rain Gauge into the correct sockets. These are label on the plastic under
the sockets.
So that data can be transmitted to the main unit, then put the radiation shield onto the
thermo-hygro sensor, please follow the below display:
Note: please don’t put in or take off the plug very often,or put the plug outside in the
air so long time to avoid any damage of the plug , if so, there will be bad
connection.
6) Mounting all the sensors onto the stainless steel mast and fix the whole parts at
outdoor open area (please refer to the illustration above)
Note: please make sure all the cables are connected well into the sockets)
Initial Operation
After inserting the batteries, the altitude flshing in meters, press “UP “ or “DOWN “ to set
the altitude of your position, then press ”SNOOZE/LIGHT” to confirm
The weather icon flashing, press “UP “ or “DOWN “ to choose the weather, then
press ”SNOOZE/LIGHT” to confirm
This process takes about 3 minutes. Then the display shows the outdoor temperature
/humidity/wind speed/wind direction/rainfall, in case of failure of reception , please press
“OUT“ for more than 3 seconds to receive again.
Once radio signal receiving is successful, the display shows the symbol “radio
tower“ continuously
Information
Please observe a minimal distance of 2.5m to sources of interference such as televisions
or computer screens.
The radio signal is weaker in rooms with concrete walls (e.g. in the basement) and in
office buildings. For extreme cases, please put the main unit near a window.
There are less atmospheric disturbances at night. A radio time signal reception is usually
possible at that time. One synchronization per day is sufficient to keep the time display
accuracy at 1 second.
Manual set-up
Press “MODE“to switch to the “Time display mode“
Press and hold key “MODE“ for 3 seconds.
The 12/24 hour flashing. Use “UP “ and “DOWN “ to select
Press “MODE “ to confirm.
The DM/MD flashing, Use “UP “ and “DOWN “ to select
Press “MODE “ to confirm.
The display for the year is flashing. Use “UP “ and “DOWN “ to select the year.
Press “MODE “ to confirm.
The display for the month is flashing. Use“UP “ and “DOWN “ to select the month.
Press “MODE “ to confirm.
The display for the date is flashing. Use “UP “ and “DOWN “ to select the date.
Press “MODE “ to confirm.
The display for the hour is flashing. Use “UP“ and “DOWN “ to select the hour.
Press “MODE “ to confirm.
The display for the minutes is flashing. Use “UP “ and “DOWN “ to select the minutes..
Press “MODE “ to confirm.
The language selection for the display of the weekdays is flashing. Use “UP “ and
“DOWN “ to select the language (GER- German, ENG - English, ITA - Italian, FRE French, DUT - Dutch, SPA - Spanish, DAN - Danish).
Press “MODE “ to confirm
The F/C for temperature flashing, Use “UP “and “DOWN “to select.
Press “MODE “ to confirm.
The hPa/inHg for air pressure flashing, Use “UP “ and “DOWN“ to select .
Press “MODE “ to confirm.
The mm/inch for rainfall and kmh/mph flashing, Use “UP “and“DOWN “to select.
Press “MODE “ to confirm.
Information:
The clock automatically exit the set-up mode if no keys are pressed for 20 seconds.
Daily alarm set-up
Press “MODE” to switch to “Alarm1” mode, “A1” and the alarm displayed
Press and hold the key “MODE” for 3 seconds ,the flashing alarm time are shown
The hour display of the alarm time is flashing. Use “UP “and “DOWN “to select the hour.
Press “MODE” to confirm.
Then follow the minutes. Use “UP “ and “DOWN “ to select the minutes,
Press “MODE” to confirm.
Then press “MODE” to switch from A1 display to A2 display
The same setting as for A2.
Daily alarm on/off
Press “MODE” to switch from time display to “Alarm 1” or “Alarm 2” mode
When showing A1 or A2 alarm time, press “UP“or “DOWN” to activate the alarm with
alarm symbol showing.
Press “UP’ or “DOWN” again to cancel the alarm
Information:
The clock automatically changes from set-up mode to time mode if no keys are pressed
for 20 seconds.
The alarm sounds for 2 minutes if no key is pressed to stop it.
Snooze function
To activate the snooze function, follow the steps below
Press the key “SNOOZE/LIGHT“, while the alarm sounds, to activate the snooze function.
If the snooze function is activated, alarm symbol is flashing.
The alarm repeat after 5 minutes.
The snooze function can be stopped by pressing any key.
Temperature alert set-up
Press “MODE” to switch to “Temperature alert” mode
In the “Temperature alert” mode, the indoor / outdoor temperature alert upper limit and the
icon displayed.
Press “MODE” again the indoor / outdoor temperature alert lower limit and icon
displayed.
In the “Temperature alert” mode, press and hold the “MODE” key, the “alert up / down”
icon flashing.
Press “UP” or “DOWN” to set the alert on or off. The “alert up / down” icon showed
when it turned on.
Press “MODE” to confirm
The indoor upper limit temperature alert and the upper alert icon are flashing, press
“UP” or “DOWN” to set the maximum alert temperature.
Press “MODE” to confirm
The indoor lower limit temperature alert and the lower alert icon are flashing, press
“UP” or “DOWN” to set the minimum alert temperature.
Press “MODE” to confirm
The outdoor upper limit temperature alert and the upper alert icon are flashing,
press “UP” or “DOWN” to set the maximum alert temperature.
Press “MODE” to confirm
The outdoor lower limit temperature alert and the lower alert icon are flashing, press
“UP” or “DOWN” to set the minimum alert temperature.
Press “MODE” to confirm, the weather station will return to the “Time display mode”
Information
The clock automatically changes from temperature alert mode to time mode if no keys are
pressed for 20 seconds.
The lower alert temperature selected must at least be 1°C below the upper alert selected
temperature.
Temperature alert ring:When the temperature reach the alert level and when alert turned on, the alert symbol
flash with alert sound
Press any key to stop the alert sound, the alert symbol and corresponding temperature still
flash until the temperature is out of alert range
Or press“MODE” to switch to the “Temperature alert mode”, press and hold the “MODE”
key to enter setup, then press “UP” or “DOWN” to deactivate the alert
12/24 hours mode
The time display can be in 12(AM/PM)or 24 hours mode, please follow the “Manual
set-up” section to select
°F /°C temperature display
The temperature display can be in °F or °C , please follow the “Manual set-up” section to
select.
Max. / Min. for the indoor/outdoor temperature and humidity
Press“MODE” to switch to “Time display” / “Indoor temperature alert” / “Outdoor
temperature alert” mode
Press “UP” to display indoor and outdoor max temperature and humidity,
Press ”UP” again to display indoor and outdoor min temperature and humidity
Hold “UP” for more than 3 seconds to clear up the max./min.
Wind speed in mph/kmh ( 0~256kmh)
The wind speed can be shown in mph and kmh, please follow the “Manual set-up”
section to select mph/kmh, the display of the speed is updated in case of the sensor
updated every 1 minute.
Wind direction
There will be 16 wind directions, the display of the direction is updated in case of the
sensor updated every 1 minutes
Rainfall display ( 0~999.99mm)
Rain fall can be shown in mm and inch, please follow the “Manual set-up” section to
select the mm/inch.
Press “MODE”to switch to “Time display” mode.
Press “DOWN” to switch to 1Hour, press again to 24 Hour, then Total wind speed and
rainfall
Press and hold “DOWN“ to clear up the volume accordingly, such as if showing 1 hour,
clear up the data in 1 hour, others unchanged, if showing 24 hours, clear up the data in 24
hour, others unchanged.
The max. of the rainfall is up to 999.99mm (99.99inch), the display is flashing in case of
Sunny
Slightly Sunny
Cloudy
Rainy
Heavy Rain
Indications on the
display
Temperature and
Rising
Constant
Falling
the max., you have to clear up the data by hand, otherwise, the data can not be updated
any more.
Weather forecast
Remarks:
As the weather forecast is calculated by air pressure only, the display will have
discrepancy with the actual weather.
Currently displayed icon means the forecast for the next 12–24 hours. It may not reflect
the current state of the weather.
Altitude setting and barometer
After inserting batteries or plugged in adaptor into the weather station, or by pressing
and holding the “SNOOZE/LIHGT” button, set your altitude for more precise pressure
calculation.
Use the “UP” and “DOWN” buttons to set a value in the range -190 m to 2000 m (10
m increment). , press “SNOOZE/LIHGT” to confirm.
After setting the altitude, use “UP” and “DOWN” buttons to set the weather forecast
icon, press “SNOOZE/LIHGT” to confirm
For accurate barometric pressure trends, the weather station should operate at the
same altitude for recordings (i.e. it should not be moved from the ground to the second
floor of the house). When the unit is moved to a new location, discard readings for the
next 12 hours and correct the height adjustment (see "Initial operation") if needed.
Temperature, humidity and pressure trends
The arrow shows the trends of values of the temperature and humidity measurements on
sensor or station.
humidity trends
New
moon
Waxing
crescent
First
quarter
Waxing
gibbous
Full moon
Waning
gibbous
Last
quarter
Waning
crescent
Comfortable
Dry
Wet
Moon phase display
Icons for the main phases of the moon are as follows:
Living space icon
The weather station uses saved data to determine the indoor humidity in the living space to
show the respective symbols for your health and home environment.
If the indoor humidity is within 40–70 % RH and the temperature within 20–28 °C, the
icon (comfortable environment) will be displayed.
If the indoor humidity is lower than 40 % RH, the icon (dry environment) will be
displayed.
If the indoor humidity is higher than 70 % RH, theicon (wet environment) will be
displayed.
If the temperature is not within 20–28 °C and humidity is within 40–70% RH, no icon will
be displayed.
Feel Like and Dew Point
Press “IN”to display “Feel Like”, press “IN” again to display “Dew Point”
Display screen not working
Check the batteries in main unit are inserted and power
adaptor is plugged in correctly
No outdoor sensor
reception
Check the batteries in sensor are inserted correctly
Battery may need to be replaced
"Feel Like” temperature is a measurement of how hot or cold you really feel like. It is
measured by the temperature, humidity, and wind speed.
“Dew point” is the temperature to which air must be cooled to become saturated
with water vapor.
When the dew point value is below 0°C, “LL.L” display
When the dew point value is above 60°C, “HH.H” display
Heat Index and Wind Chill
Press “Out”to display “Heat Index”, press “Out” again to display “Wind Chill” “Heat Index” combines the factors of heat and humidity. It is the apparent temperature of
how hot it feels to a human being.
Note: Heat Index is only displayed when temperature above 26.7°C
“Wind Chill” is a measure of how cold felt by the body on exposed skin due to the flow
of air.
Note: Wind Chill is only displayed when temperature below 5°C and wind speed above
3kmh
Backlight
When plugged in power adaptor, press “Snooze/Light” to dim the backlight
brightness or turn the display off
When powered by batteries only, the backlight will be automatically off after 10
seconds without pressing any keys, press “Snooze/Light” to activate it for 10
seconds.
Low battery condition display
The weather station displays the low battery condition symbol to remind the batteries of the
weather station or the outdoor sensor need to be exchanged.
Weather station low battery condition display: within indoor area of the display
Outdoor sensor low battery condition display: in the outdoor area of the display
Troubleshooting
Relocate the weather station and the sensor. The
maximum transimission range is 100m without obstriction
Press and hold “OUT“ key for RF reception again
Try to reset the units, take the sensor near the weather
station, reinstall the batteries and replug power adaptor,
place the sensor outdoor until reception success
Check the distance of the weather station and the sensor
from the sources of interference (computer monitors or
television sets). It should be at least 1.5 to 2 m during the
reception of the signal.
Rainfall display error
Remove rain gauge cover to see if any obstruction inside
Make sure the rain gauge is mounted securely
Make sure the outdoor sensor cable connect properly
Inaccurate weather
forecast
Currently displayed icon means the forecast for the next
12–24 hours. It may not reflect the current state of the
weather.
Set the correct altitdue
For accurate barometric pressure trends, the weather
station should operate at the same altitude for recordings
(i.e. it should not be moved from the ground to the second
floor of the house). When the unit is moved to a new
location, discard readings for the next 12 hours and
correct the height adjustment if needed
Wrong temperature
Press “MODE“ to check if it is in alert mode. In the alert
mode, the unit will display the alert upper or lower limit.
Care and maintenance
Read carefully the manual before using this product.
Do not expose the main unit to direct sunlight, extreme cold and moisture, and sudden
changes in temperature. This would reduce the accuracy of detection.
Do not place the product in locations prone to vibration and shocks – these may cause
damage.
Do not expose the product to excessive force, impacts, dust, high temperatures or
humidity - these may cause malfunction, shorter battery life, damage to batteries and
deformation of plastic parts.
Do not expose the main unit to rain or moisture, if it is not intended for outdoor use.
Do not place any open flame sources on the product, e.g. a lit candle, etc.
Do not place the product to places with inadequate air flow.
Do not insert any objects in the product vents.
Do not tamper with the internal electric circuits of the product – you may damage it, which
will automatically terminate the guarantee. The product should only be repaired by a
qualified professional.
To clean the product, use a slightly moistened soft cloth. Do not use solvents or cleaning
agents - they could scratch plastic parts and damage electric circuits.
Do not immerse the product in water or other liquids.
The main unit may not be exposed to dripping or splashing water.
In the event of damage or defect of the product, do not perform any repairs by yourself.
The transmitter of the wireless indoor/outdoor thermometer works down to -20°C, but at
low temperatures, especially for a long period of time, the batteries may freeze, which
may prevent the transmitter from transmitting the signal to the receiver and at the same
time the transmission range is reduced at very low temperatures.
This device is not intended for use by persons (including children) whose physical,
sensory or mental disability or lack of experience and expertise prevents safe use, unless
they are supervised or instructed regarding use of the appliance by a person responsible
for their safety. It is necessary to supervise children to ensure they do not play with the
device.
Note
Manufacturer reserves the right to change specifications of the product.
Manufacturer and supplier are not responsible for malfunction where interference occurs.
This product is not intended for medical or commercial purposes.
Technical data
a) Main Unit
Barometer unit: hPa / inHg
Barometer pressure measuring range: 850hPa to 1050hPa
Weather display: Sunny, Slightly Sunny, Cloudy, Rainy, Storm
Temperature unit: °F / °C
Temperature measurement range: 32~122°F ( 0 °C to +50 °C)
Indoor temperature / humidity trend and max / min function
Moon phase
Humidity measurement range: 20 to 95%
Living space humidity display
Time display: 12/24 hour format
Calendar: DD/MM or MM/DD
Weekday in 7 languages: German, English, French, Italian, Dutch, Spanish, Danish
Dual alarm with snooze function (5 minutes alarm interruption)
Blue back light
Power supply : 3 X AAA, UM-4, LR03 1.5V batteries, DC 5.0V power adapter
b) Outdoor sensor
Transmission frequency: 433 MHz
Transmission range: up to 100 m in open area with no obstruction
Temperature measurement range: -68 to 158°F ( -20 °C to +70 °C)
Humidity measurement range: 20 to 95%
Outdoor temperature / humidity trend and max / min function
Rainfall measurement range: 0 to 999.99mm
Wind speed measurement range: 0 to 256kmh
Wind direction in 16 directions
Power supply: 2 X AA, UM-3, LR6 1.5V batteries
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2)This device must
accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio / TV technician for help.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.