anvil international 459, 551, 552 User Manual

MALLEABLE IRON FITTINGS
Malleable Iron Unions • Class 150; 250; 300
BRONZE TO IRON
Unions
FIGURE 459
q
Class 300 Union
300lb. wsp · 600lb. wog non-shock
For Listings/Approval Details and Limitations,
visit our website at www.anvilintl.com
or contact an Anvil Sales Representative.
FIGURE 551
q
Class 300 Union male & female
300lb. wsp · 600lb. wog non-shock
Size End to End
NPS DN in mm lbs kg lbs kg
1
8 6 15⁄16 33 0.14 0.06 0.14 0.06
1
4 8 113⁄16 47 0.48 0.22 0.48 0.22
3
8 10 113⁄16 47 0.42 0.19 0.42 0.19
1
2 15 21⁄16 52 0.64 0.29 0.64 0.29
3
4 20 21⁄4 57 1.00 0.45 1.00 0.45
1 25 2
1
1
4 32 23⁄4 70 2.30 1.04 2.30 1.04
1
1
2 40 3 76 2.74 1.24 2.74 1.24
2 50 3
1
2
2 65 37⁄8 98 5.05 2.29 5.05 2.29 3 80 4 4 100 4
1
2 15 3 76 0.62 0.28
3
4 20 33⁄16 81 0.92 0.42
9
16 65 1.56 0.71 1.56 0.71
3
8 86 4.34 1.97 4.34 1.97
1
4 108 7.66 3.47 7.66 3.47
7
8 124 17.70 8.03 17.70 8.03
Unit Weight
Black Galv.
1 25 3
1
2 40 41⁄4 108 2.60 1.18
1
2 50 4
FIGURE 552
q
Class 300 90° Elbow
Female Union 300lb. wsp
Size
NPS DN in mm in mm lbs kg
3
8 10 11⁄16 27 21⁄16 52 0.51 0.23
1
2 15 11⁄4 32 25⁄16 59 0.79 0.36
3
4 20 17⁄16 37 23⁄4 70 1.24 0.56
1 25 1
See following page for pressure-temperature ratings.
• Anvil Malleable Iron Unions conform to ASME B 16.39.
• Dimensions conform to ASME B 16.39 for Class 150, 250 & 300 Unions.
5
8 92 1.54 0.70
5
8 117 4.21 1.91
Center to End Unit Weight
Elbow Union Black
5
8 41 3 76 1.88 0.85
wsp=working steam pressure wog=water, oil, gas
PROJECT INFORMATION APPROVAL STAMP
Project:
Address:
Contractor:
Engineer: Remarks:
Submittal Date:
Notes 1:
Notes 2:
PF-11.16
Approved
q
Approved as noted
q
q
MALLEABLE IRON FITTINGS
Malleable Iron Threaded Pipe Unions
Pressure - Temperature Ratings
Temperature
(°F) (°C) psi bar psi bar psi bar
-20°
150°
200° 93.3° 265 18.3 455 31.4 550 37.9
250° 121.1° 225 15.5 405 27.9 505 34.8
300° 148.9° 185 12.8 360 24.8 460 31.7
350° 176.7° 150 10.3 315 21.7 415 28.6
400° 204.4° 110 7.6 270 18.6 370 25.5
450° 232.2° 75 5.2 225 15.5 325 22.4
500° 260.0° 180 12.4 280 19.3
550° 287.8° 130 9.0 230 15.9
Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F
For Listings/Approval Details and Limitations, visit our website at
-28.9°
to
to
65.6°
www.anvilintl.com or contact an Anvil Sales Representative.
Class 150 Class 250 Class 300
300 20.7 500 34.5 600 41.4
Pressure
Malleable Iron Threaded Fittings
Pressure - Temperature Ratings
Pressure
Temperature
(°F) (°C) psi bar psi bar psi bar psi bar
-20° to
150°
200° 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7
250° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9
300° 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7
350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8
400° 204.4 935 64.5 750 51.7 560 38.6
450° 232.2 725 50.0 600 41.4 475 32.8
500° 260.0 510 35.2 450 31.0 385 26.5
550° 287.8 300 20.7 300 20.7 300 20.7
Class 150
-28.9° to
300 20.7 2,000 137.9 1,500 103.4 1,000 68.9
65.6°
Sizes 1⁄4"–1"
(6–25 mm)
Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39.
ALL ELBOWS & TEES 3⁄8" (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar)
Class 300
Sizes 11⁄4"–2"
(32–51 mm)
Sizes 21⁄2"–3"
(64–76 mm)
Standards and Specifications
Dimensions Material Galvanizing
*
Thread Pressure Rating
MALLEABLE IRON FITTINGS
Class 150/PN 20 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3 Class 300/PN 50 ASME B16.3 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.3
MALLEABLE IRON UNIONS
Class 150/PN 20 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 250 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39 Class 300/PN 50 ASME B16.39 ASTM A-197 ASTM A-153 ASME B1 20.1 ASME B16.39
* ASTM B 633. Type I, SC 4, may be supplied as alternate zinc coating per applicable ASME B16 product standard.
PF-11.16
MALLEABLE IRON FITTINGS
General Assembly of Threaded Fittings
1) Inspect both male and female components prior to assembly.
• Threads should be free from mechanical damage, dirt, chips and excess cutting oil.
• Clean or replace components as necessary.
2) Application of thread sealant
• Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant may be utilized.
• Thoroughly mix the thread sealant prior to application.
• Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads.
3) Joint Makeup
• For sizes up to and including 2" pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1⁄2" through 2" thread varies from 41⁄2 turns to 5 turns.
• For 21⁄2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21⁄2" through 4" thread varies from 51⁄2 turns to 63⁄4 turns.
PF-11.13