Antunes UTX-200L User Manual

A. J. ANTUNES & CO.
180 Kehoe Blvd., Carol Stream, Illinois 60188
UTX-200 DIAGNOSTIC FLOWCHART SHEET
CAUTION To avoid possible personal injury and/or damage to the unit, all inspections, tests, and repair of electrical equipment should be performed by QUALIFIED SERVICE PERSONNEL. The unit MUST be completely shut down and unplugged before servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.
TOOLS: Clamp-on Ammeter.
AFFECTED PRODUCTS: All UTX-200 units.
Introduction
The purpose of this document is to provide diagnostic infor­mation for the UTX-200 Universal Toaster. The diagnostic areas covered in this document include:
Upper IR Heaters (Infrared) Circuit•
Lower IR Heaters (Infrared) Circuit•
Platen Heater Circuit•
Conveyor System•
This document also includes the wiring diagrams and sche­matics to assist in diagnosing problems with the UTX-200.
This document includes the UTX-200 Diagnostic Service Mode document (p/n 1011010). This document describes the Diagnostic Service Mode for the UTX-200 and will help with troubleshooting the system.
Because of the size and scope of the diagnostic flow­charts, they begin on the next page. Please continue to the next page for more information.
1-877-392-7854 Fax: 630-784-1649 P/N 1011016 02/09
Page 1 of 16
McDonald’s
A. J. ANTUNES & CO.
High Limit
Tripped?
Upper IR Heater Errors
no
Manually reset
High Limit
yes
Enter Diagnostic Mode
(refer to doc. #1011010)
Step to Is contactor
On? Are all SSRs Off?
no
Is Amperage
flowing in
L1, L2, or L3?
(should be < 1.0 A)
Shorted SSR
yes
Press NEXT once.
Measure amps & compare
Table 1 to the Upper IR
display
Components in Upper IR Circuit
· Contactor C1
· IR Heaters 1, 2, 3 and 5, 6, 7
· Upper IR Circuit Solid State Relay (SSR)
· Wires-9,16,18,21,26, 27, 28, 30 thru 33
· 4 wire Cable from I/O board to SSR plug
· 6 wire Cable from Display Board to Current Sense board
· Current Sense board
· Refer to Diagrams page in this document
yes
Is the I/O
board “TOP”
Led on?
yes
I/O board may
be faulty.
Is the
I/O board “TOP”
Led on?
no
Continued on
next page
no
DIAGNOSTIC MODE
· Turn off power switch, then back on. Listen for 3 “Clicks.”
· Press and hold the ADJUST and UT buttons for 5 seconds
· Press the NEXT twice, then the SELECT
· This will place the toaster in Diagnostics mode
End
End
Turn power on with rear
rocker switch
Hear 3 clicks?
yes
Refer to
PLATEN
chart
no
Repeat Power- On and
watch the
CONTACTOR LED on
the I/O board
LED flashes
3 times?
yes
The 208V/240V power from the I/O board
is not reaching the contactor coil.
Possible open coil: faulty harness; open
Hi-Limit, power switch, or switch wiring
Possible faulty I/O
board
no End
The High Limit senses the internal Platen temp. If tripped, It prevents the contactor C1 from closing. This prevents Amperage flow to ALL heaters. A tripped Hi-Limit is an indication of a PLATEN problem such as a shorted/grounded thermocouple or shorted Platen SSR. It is set to trip at 700F
UPPER I/R DIAGNOSTIC FLOWCHART
180 Kehoe Blvd., Carol Stream, Illinois 60188
1-877-392-7854 Fax: 630-784-1649 P/N 1011016 02/09
Page 2 of 16
McDonald’s
A. J. ANTUNES & CO.
Does display
agree with
Table 1?
yes
Do the measured
amps equal Table 1?
yes
no
yes
The amps are correct. This may indicate an Intermittent connection on the current Sense board or connecting cable Inspect cable and board
The Amperages are correct but are not being measured correctly by the toaster, possibilities:
· faulty connection on the current Sense board or connecting cable
· Inspect cable and board
· Wires passing through the current Sense Board are incorrectly routed. Refer to current sense board for correct wiring
The measured amps are not correct so the problem exist in the heaters, wiring, SSRs or cables.
· Open heater (H1, 2, 3, 5, 6, 7)
· faulty wire connection on heater or top IR SSR
· Open SSR - TOP
· Faulty SSR DC cable from I/O board
· Burnt Plug Prongs
· Open Pole on Contactor
· Missing 3 Phase 208-240 Volt Supply
· Open/Burnt Terminal at 4 Pole Terminal Block
Measure the
Amperage in wires
BLK # 9 & RED
# 16 at Upper IR
SSR
no
Control boards are
functioning OK in
Upper IR mode
End
End
Continued from
Previous page
UPPER I/R DIAGNOSTIC FLOWCHART (CONTINUED)
180 Kehoe Blvd., Carol Stream, Illinois 60188
1-877-392-7854 Fax: 630-784-1649 P/N 1011016 02/09
Page 3 of 16
McDonald’s
A. J. ANTUNES & CO.
Enter Diagnostic Mode
(refer to doc. #1011010)
Step to Is contactor
On? Are all SSRs Off?
no
Is Amperage
flowing in
L1, L2, or L3?
(should be < 1.0 A)
Shorted
SSR
no
yes
Press NEXT once.
Measure amps & compare
Table 1 to the Lower IR display
yes
Is the I/O
board “BOTTOM”
Led on?
yes
I/O board may
be faulty.
Is the
I/O board
“BOTTOM” Led
on?
no
Continued on
Next Page
no
DIAGNOSTIC MODE
· Turn off power switch, then back on. Listen for 3 “Clicks.”
· Press and hold the ADJUST and UT buttons for 5 seconds
· Press the NEXT twice, then the SELECT
· This will place the toaster in Diagnostics mode
Components in Lower IR Circuit
Contactor C1 IR Heaters 4, 8 & 9 Lower IR Circuit Solid State Relay (SSR) Wires-10, 13, 15, 19, 22, 29, 35 4 wire Cable from I/O board to SSR plug 6 wire cable from Display Board to Current Sense board Current Sense board Refer to Diagrams page in this document
High Limit
Tripped?
Lower IR Heater Errors
no
Manually reset
High Limit
yes
no
Turn power on with rear
rocker switch
Hear 3 clicks?
Refer to
PLATEN
chart
Repeat Power- On and
watch the
CONTACTOR LED on
the I/O board
LED flashes
3 times?
yes
The 208V/240V power from the I/O
board is not reaching the contactor coil.
Possible open coil: faulty harness; open
Hi-Limit, power switch, or switch wiring
no End
yes
Possible faulty I/O
board
The High Limit senses the internal Platen temp. If tripped, It prevents the contactor C1 from closing. This prevents Amperage flow to ALL heaters. A tripped Hi-Limit is an indication of a PLATEN problem such as a shorted thermocouple or shorted/grounded Platen SSR. It is set to trip at 700F
End
End
LOWER I/R DIAGNOSTIC FLOWCHART
180 Kehoe Blvd., Carol Stream, Illinois 60188
1-877-392-7854 Fax: 630-784-1649 P/N 1011016 02/09
Page 4 of 16
McDonald’s
A. J. ANTUNES & CO.
Does display
agree with
Table 2?
yes
Do the measured
amps equal Table 2?
yes
no
yes
The amps are correct. This may indicate an Intermittent connection on the current Sense board or connecting cable Inspect cable and board
The Amperages are correct but are not being measured correctly by the toaster, possibilities:
· faulty connection on the current Sense board or connecting cable
· Inspect cable and board
· Wires passing through the current Sense Board are incorrectly routed. Refer to current Sense board for correct wiring
The measured amps are not correct so the problem exist in the heaters, wiring, SSRs or cables.
· Open heater (H4, H8, H9)
· Faulty wire connection on heater or bottom IR SSR
· Open SSR - BOTTOM
· Faulty gray SSR DC cable from I/O board
· Burnt Plug Prongs
· Open Pole on Contactor
· Missing 3 Phase 208-240 Volt Supply
· Open/Burnt terminal at 4 Pole Terminal Block
Measure the
Amperage in wires
BLK # 10 & RED # 15 at Lower IR
SSR
no
Control boards are
functioning OK in
Lower I/R mode
Continued from
Previous page
End
End
LOWER I/R DIAGNOSTIC FLOWCHART (CONTINUED)
180 Kehoe Blvd., Carol Stream, Illinois 60188
1-877-392-7854 Fax: 630-784-1649 P/N 1011016 02/09
Page 5 of 16
McDonald’s
Loading...
+ 11 hidden pages