Filtration Process .................................................... 10
2
OWNER INFORMATION
General
Antunes Filtration Technologies, Division of A.J.
Antunes & Co., has partnered with companies from
around the globe to produce the UFC-Series water fil
tration systems. The UFC-Series removes bacteria and
provides a substantial reduction of viruses that can
enter a typical water supply. This patented technology
is now available to you, sized for your particular appli
cation. All filter configurations utilize NeoH capillary
membranes, providing the latest innovation in reusable
surface filtration technology.
This manual provides the safety, installation and
operating procedures for the UFC-Series water filtration
systems. We recommend that all information contained
in this manual be read prior to installing and operating
the unit.
Your UFC-Series unit is manufactured from the finest
materials available and is assembled to AFT’s strict
quality standards. This unit has been tested at the
factory to ensure dependable trouble-free operation.
-
-
LED Display ...........................................................
Starting the System ................................................ 10
LIMITED WARRANTY ............................... Back Cover
Warranty Information
Please read the full text of the Limited Warranty in this
manual.
If the unit arrives damaged, contact the carrier imme
diately and file a damage claim with them. Save all
packing materials when filing a claim. Freight damage
claims are the responsibility of the purchaser and are
not covered under warranty.
The warranty does not extend to:
• Damages caused in shipment or damage as
result of improper use.
• Installation of electrical service.
• Normal maintenance as outlined in this manual.
• Malfunction resulting from improper maintenance.
• Damage from moisture leaking into electrical
components.
• Normal maintenance as outlined in this manual.
10
-
• Damage from tampering with, removal of, or
changing any preset control or safety device.
IMPORTANT! Keep these instructions for future reference. If the unit changes owner-
ship, be sure this manual accompanies the equipment.
2
P/N 1010907 07/05
UFC SERIES WATER FILTRATION SYSTEM
OWNER INFORMATION (continued)
Service/Technical Assistance
If you experience any problems with the installation
or operation of your unit, contact Antunes Filtration
Technologies at
United States at
Fill in the information in the next column and have it
handy when calling for assistance. The serial number
is on the specification plate located on the unit.
1-630-784-1000, or toll free in the
1-800-253-2991.
Purchased From:
Date of Purchase:
Model No.:
Serial No.:
Mfg. No.:
IMPORTANT
Antunes Filtration Technologies reserves the right to change specifications and product
design without notice. Such revisions do not entitle the buyer to corresponding chang
es, improvements, additions or replacements for previously purchased equipment.
IMPORTANT SAFETY INFORMATION
Throughout this manual, you will find the following
safety words and symbols that signify important safety
issues with regards to operating or maintaining the unit.
In addition to the warnings and cautions in this manual,
use the following guidelines for safe operation of the
unit.
-
WARNING
GENERAL WARNING. Indicates information important to the proper operation of
the equipment. Failure to observe may
result in damage to the equipment and/or
severe bodily injury or death.
WARNING
ELECTRICAL WARNING. Indicates information relating to possible shock hazard.
Failure to observe may result in damage
to the equipment and/or severe bodily
injury or death.
CAUTION
GENERAL CAUTION. Indicates information important to the proper operation of
the equipment. Failure to observe may
result in damage to the equipment.
• Read all instructions before using equipment.
• For your safety, the equipment is furnished with
a properly grounded cord connector. Do not
attempt to defeat the grounded connector.
• Install or locate the equipment only for its intend
ed use as described in this manual. Do not use
corrosive chemicals in this equipment.
• Do not operate this equipment if it has a dam
aged cord or plug; if it is not working properly, or
if it has been damaged or dropped.
• This equipment should be serviced by quali
fied personnel only. Contact Antunes Filtration
Technologies for repair.
• Do not immerse cord or plug in water.
• Keep cord away from heated surfaces.
-
-
-
P/N 1010907 07/05
3
UFC SERIES WATER FILTRATION SYSTEM
IMPORTANT SAFETY INFORMATION (continued)
The following warnings and cautions appear throughout
this manual and should be carefully observed.
• Turn the unit off and disconnect the power source
before performing any service or
maintenance on the unit.
• The equipment should be grounded according to
local electrical codes to prevent the possibility of
electrical shock. It requires a grounded recep
tacle with separate electrical lines, protected by
fuses or circuit breaker of the proper rating.
• All electrical connections must be in accordance
with local electrical codes and any other appli
cable codes.
• WARNING ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN SERIOUS INJURY OR
DEATH.
- Electrical ground is required on this
appliance.
- Do not modify the power supply cord plug. If
it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
-
-
- Do not use an extension cord with this appli
ance.
- Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
• If the supply cord is damaged, it must be
replaced by the manufacturer or its service agent
or a similarly qualified person.
• This equipment is to be installed to comply with
the local plumbing code and any other applicable
code.
• Water pressure must not exceed the membrane
differential pressure of 45 psig (3.1 bar). To
reduce water pressure, install a water pressure
regulator and set the system inlet water pressure
to 45 psi (3.1) bar.
-
WATER CONDITION EQUIPMENT GUIDELINES
Inlet Water
Pressure
(psi)
Less than 45 psiLess than 1 NTU
Greater than
45 psi
Less than 45 psiGreater than
Greater than
45 psi
Inlet Turbidity
(NTU)
Less than 1 NTURequired: Pressure regulator
1 NTU
Greater than
1 NTU
Required Additional Equipment
Installed
Required: No additional equipment
Recommended: Inlet water strainer
(150 micron/ 100 mesh screen)
Recommended: Permeate Tank
Recommended: Inlet water strainer
(150 micron/ 100 mesh screen)
Recommended: Permeate Tank
Required: Inlet water strainer (150
micron/ 100 mesh screen)
Required: Permeate Tank
Required: Pressure regulator
Required: Inlet water strainer (150
Maximum Operating Pressure 3 bar (45 psi)
Maximum Operating Temp. 40°C (104°F)
Trans Membrane Pressure 0.5-2.5 Bar (7-36 psi)
pH Range 3-10
MWCO 100 kD
Sanitizing Temp. 80°C (176°F)
Dimensions
WARNING
ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THE INSTRUCTIONS IN
THIS MANUAL COULD RESULT IN SERIOUS INJU
RY OR DEATH.
• Electrical ground is required on this appliance.
• Do not modify the power supply cord plug. If
it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
• Do not use an extension cord with this
appliance.
• Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other
applicable codes.
-
Figure 1. Dimensions
A
Width
7 inches
177.8 (mm)
B
Depth
3.125 inches
(79.35 mm)
Height
26.25 inches
(666.75 mm)
C
Operating
Weight
(w/ water)
13 lbs.
(5.9 kilos)
P/N 1010907 07/05
5
UFC SERIES WATER FILTRATION SYSTEM
SPECIFICATIONS
Components
Permeate
(Product Water)
Drain
LED Display
Start Button
Power Cord
Water Inlet
Figure 2. Components
6
P/N 1010907 07/05
Loading...