Antunes UFC-216 Installation Manual

MANUFACTURING
9700600 9700602 9700603
WATER FILTRATION
P/N 1010907 07/05
SYSTEM
UFC 216 Series
Owner’s Manual
UFC SERIES WATER FILTRATION SYSTEM
TABLE OF CONTENTS
Owner Information .....................................................
General ......................................................................2
Warranty Information .................................................2
Service/Technical Assistance ....................................3
Important Safety Information ....................................3
Specifications .............................................................5
Electrical Ratings .......................................................5
Electrical Cord & Plug Configurations .......................5
Specifications (Filter Cartridges) ...............................5
Dimensions ................................................................5
Specifications .............................................................6
Components ..............................................................6
Installation ...................................................................7
Unpacking ..................................................................7
Equipment Setup .......................................................7
Locating and Mounting the system ...........................8
Operation ...................................................................10
Filtration Process .................................................... 10
2
OWNER INFORMATION
General
Antunes Filtration Technologies, Division of A.J. Antunes & Co., has partnered with companies from around the globe to produce the UFC-Series water fil tration systems. The UFC-Series removes bacteria and provides a substantial reduction of viruses that can enter a typical water supply. This patented technology is now available to you, sized for your particular appli cation. All filter configurations utilize NeoH capillary membranes, providing the latest innovation in reusable surface filtration technology.
This manual provides the safety, installation and operating procedures for the UFC-Series water filtration systems. We recommend that all information contained in this manual be read prior to installing and operating the unit.
Your UFC-Series unit is manufactured from the finest materials available and is assembled to AFT’s strict quality standards. This unit has been tested at the factory to ensure dependable trouble-free operation.
-
-
LED Display ...........................................................
Starting the System ................................................ 10
Programming Timer ................................................11
Setting the Flush Interval (Fi) .................................. 11
Setting Flush Duration (Fd) ..................................... 11
Programming Timer While Unit is in Flush Interval (Fi)
Mode ....................................................................... 12
Manual Flushing ..................................................... 13
Maintenance .............................................................. 14
Checking the Timer Program .................................. 14
Changing the Cartridges ........................................ 14
Troubleshooting .......................................................15
Replacement parts UFC-216 ................................... 16
Recommended Equipment Schematic ...................17
Wiring Diagram .........................................................18
Notes..........................................................................19
LIMITED WARRANTY ............................... Back Cover
Warranty Information
Please read the full text of the Limited Warranty in this manual.
If the unit arrives damaged, contact the carrier imme diately and file a damage claim with them. Save all packing materials when filing a claim. Freight damage claims are the responsibility of the purchaser and are not covered under warranty.
The warranty does not extend to:
• Damages caused in shipment or damage as result of improper use.
• Installation of electrical service.
• Normal maintenance as outlined in this manual.
• Malfunction resulting from improper maintenance.
• Damage from moisture leaking into electrical components.
• Normal maintenance as outlined in this manual.
10
-
• Damage from tampering with, removal of, or changing any preset control or safety device.
IMPORTANT! Keep these instructions for future reference. If the unit changes owner-
ship, be sure this manual accompanies the equipment.
2
P/N 1010907 07/05
UFC SERIES WATER FILTRATION SYSTEM
OWNER INFORMATION (continued)
Service/Technical Assistance
If you experience any problems with the installation or operation of your unit, contact Antunes Filtration Technologies at United States at
Fill in the information in the next column and have it handy when calling for assistance. The serial number is on the specification plate located on the unit.
1-630-784-1000, or toll free in the
1-800-253-2991.
Purchased From:
Date of Purchase:
Model No.:
Serial No.:
Mfg. No.:
IMPORTANT
Antunes Filtration Technologies reserves the right to change specifications and product
design without notice. Such revisions do not entitle the buyer to corresponding chang
es, improvements, additions or replacements for previously purchased equipment.
IMPORTANT SAFETY INFORMATION
Throughout this manual, you will find the following safety words and symbols that signify important safety issues with regards to operating or maintaining the unit.
In addition to the warnings and cautions in this manual, use the following guidelines for safe operation of the unit.
-
WARNING
GENERAL WARNING. Indicates informa­tion important to the proper operation of the equipment. Failure to observe may result in damage to the equipment and/or severe bodily injury or death.
WARNING
ELECTRICAL WARNING. Indicates infor­mation relating to possible shock hazard. Failure to observe may result in damage to the equipment and/or severe bodily injury or death.
CAUTION
GENERAL CAUTION. Indicates informa­tion important to the proper operation of the equipment. Failure to observe may result in damage to the equipment.
• Read all instructions before using equipment.
• For your safety, the equipment is furnished with a properly grounded cord connector. Do not attempt to defeat the grounded connector.
• Install or locate the equipment only for its intend ed use as described in this manual. Do not use corrosive chemicals in this equipment.
• Do not operate this equipment if it has a dam aged cord or plug; if it is not working properly, or if it has been damaged or dropped.
• This equipment should be serviced by quali fied personnel only. Contact Antunes Filtration Technologies for repair.
• Do not immerse cord or plug in water.
• Keep cord away from heated surfaces.
-
-
-
P/N 1010907 07/05
3
UFC SERIES WATER FILTRATION SYSTEM
IMPORTANT SAFETY INFORMATION (continued)
The following warnings and cautions appear throughout this manual and should be carefully observed.
• Turn the unit off and disconnect the power source before performing any service or maintenance on the unit.
• The equipment should be grounded according to local electrical codes to prevent the possibility of electrical shock. It requires a grounded recep tacle with separate electrical lines, protected by fuses or circuit breaker of the proper rating.
• All electrical connections must be in accordance with local electrical codes and any other appli cable codes.
• WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH.
- Electrical ground is required on this appliance.
- Do not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.
-
-
- Do not use an extension cord with this appli ance.
- Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person.
• This equipment is to be installed to comply with the local plumbing code and any other applicable code.
• Water pressure must not exceed the membrane differential pressure of 45 psig (3.1 bar). To reduce water pressure, install a water pressure regulator and set the system inlet water pressure to 45 psi (3.1) bar.
-
WATER CONDITION EQUIPMENT GUIDELINES
Inlet Water
Pressure
(psi)
Less than 45 psi Less than 1 NTU
Greater than 45 psi
Less than 45 psi Greater than
Greater than 45 psi
Inlet Turbidity
(NTU)
Less than 1 NTU Required: Pressure regulator
1 NTU
Greater than
1 NTU
Required Additional Equipment
Installed
Required: No additional equipment Recommended: Inlet water strainer
(150 micron/ 100 mesh screen)
Recommended: Permeate Tank
Recommended: Inlet water strainer
(150 micron/ 100 mesh screen)
Recommended: Permeate Tank
Required: Inlet water strainer (150
micron/ 100 mesh screen)
Required: Permeate Tank
Required: Pressure regulator Required: Inlet water strainer (150
micron/ 100 mesh screen) Required: Permeate Tank
Water Use
(Gallons Per
Day)
Less than
300 GPD
Greater than
300 GPD
Less than
300 GPD
Greater than
300 GPD
Any Flush Program:
Any Flush Program:
Flush Program
Flush Program: Interval: 6 hour Duration: 15 seconds
Flush Program: Interval: 1 hour Duration: 15 seconds
Flush Program: Interval: 6 hour Duration: 15 seconds
Flush Program: Interval: 1 hour Duration: 15 seconds
Interval: 1 hour Duration: 15 seconds
Interval: 1 hour Duration: 15 seconds
4
P/N 1010907 07/05
UFC SERIES WATER FILTRATION SYSTEM
WHT
BLK
GRN
A
B
C
SPECIFICATIONS
Electrical Ratings
Voltage Watts Hertz
120 10 50/60
230 10 50/60
Electrical Cord & Plug Configurations
Letter
Description Configuration
Code*
C
H
(H)C CEE 7/7, 16 Amp.,
(C)F 5-15P, 15 Amp., 120
(H)K
Commercial Cord
Harmonized Cord
250 VAC
(Assembly Only).
VAC., Non– Locking
(Assembly Only).
Chinese/Australian,
10 Amp., 250 VAC.
(Assembly only)
Specifications (Filter Cartridges)
Maximum Operating Pressure 3 bar (45 psi) Maximum Operating Temp. 40°C (104°F) Trans Membrane Pressure 0.5-2.5 Bar (7-36 psi) pH Range 3-10 MWCO 100 kD Sanitizing Temp. 80°C (176°F)
Dimensions
WARNING
ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESULT IN SERIOUS INJU RY OR DEATH.
• Electrical ground is required on this appliance.
• Do not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.
• Do not use an extension cord with this appliance.
• Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes.
-
Figure 1. Dimensions
A
Width
7 inches
177.8 (mm)
B
Depth
3.125 inches (79.35 mm)
Height
26.25 inches (666.75 mm)
C
Operating
Weight
(w/ water)
13 lbs.
(5.9 kilos)
P/N 1010907 07/05
5
UFC SERIES WATER FILTRATION SYSTEM
SPECIFICATIONS
Components
Permeate
(Product Water)
Drain
LED Display
Start Button
Power Cord
Water Inlet
Figure 2. Components
6
P/N 1010907 07/05
Loading...
+ 14 hidden pages