UF-216CC WATER FILTRATION SYSTEM
TABLE OF CONTENTS
Owner Information .....................................................2
General ......................................................................2
Warranty Information .................................................2
Service/Technical Assistance ....................................3
Important Safety Information ....................................4
Specifications .............................................................5
Dimensions ................................................................5
Replacement Cartridges ............................................5
Ultra Filter Cartridge Capacities ................................5
Electrical Ratings .......................................................5
Electrical Cord & Plug Configurations .......................5
Overview......................................................................7
Overview ....................................................................7
Manual Flushing ........................................................7
Installation ...................................................................8
Unpacking ..................................................................8
Equipment Setup .......................................................8
Mounting the System .................................................9
OWNER INFORMATION
General
Inlet Water Plumbing .................................................9
Permeate Line Plumbing .........................................10
Drain Valve Connection ...........................................10
Starting the Controller .............................................10
Rinsing the Ultra Filter Cartridge ............................. 11
Sanitizing the System and Lines .............................11
Installing and Rinsing the Carbon Element ............12
Maintenance ..............................................................13
Replacing the Ultra Filter Cartridge .........................13
Rinsing and Replacing the Carbon Element ...........14
System Sanitization .................................................14
Changing the Interval Setting ..................................15
Resetting the Timer Program ..................................15
Troubleshooting .......................................................16
Replacement Parts .................................................. 17
Notes..........................................................................18
Limited Warranty ......................................................20
Warranty Information
VIZION, a division of A.J. Antunes & Co., has partnered with companies from around the globe to produce the UF-216CC Series water filtration system. The
UF-216CC Series reduces cysts and turbidity that can
enter a typical water supply. This patented technology
is now available to you, sized for your particular application. All filter configurations utilize NeoH capillary
membranes, providing the latest innovation in reusable
surface filtration technology.
This manual provides the safety, installation and
operating procedures for the UF-216CC Series water
filtration system. We recommend that all information
contained in this manual be read prior to installing and
operating the unit.
Your UF-216CC Series unit is manufactured from the
finest materials available and is assembled to VIZION’s
strict quality standards. This unit has been tested at the
factory to ensure dependable trouble-free operation.
Please read the full text of the Limited Warranty in this
manual.
If the unit arrives damaged, contact the carrier immediately and file a damage claim with them. Save all
packing materials when filing a claim. Freight damage
claims are the responsibility of the purchaser and are
not covered under warranty.
The warranty does NOT extend to:
• Damages caused in shipment or damage as
result of improper use.
• Installation of electrical service.
• Normal maintenance as outlined in this manual.
• Malfunction resulting from improper maintenance.
• Damage from moisture leaking into electrical
components.
• Normal maintenance as outlined in this manual.
• Damage from tampering with, removal of, or
changing any preset control or safety device.
IMPORTANT! Keep these instructions for future reference. If the unit changes
ownership, be sure this manual accompanies the equipment.
2
P/N 1011135 Rev. C 10/15
UF-216CC WATER FILTRATION SYSTEM
OWNER INFORMATION (continued)
Service/Technical Assistance
If you experience any problems with the installation or
operation of your unit, contact us at 86-512-6841-3637,
or toll free in the United States at 1-800-253-2991.
Fill in the information in the next column and have it
handy when calling for assistance. The serial number
is on the specification plate located on the unit.
Purchased From:
Date of Purchase:
Model No.:
Serial No.:
Mfg. No.:
IMPORTANT
A.J. Antunes and Co. reserves the right to change specifications and product design without
notice. Such revisions do NOT entitle the buyer to corresponding changes, improvements,
additions or replacements for previously purchased equipment.
P/N 1011135 Rev. C 10/15
3
UF-216CC WATER FILTRATION SYSTEM
IMPORTANT SAFETY INFORMATION
In addition to the warnings and cautions in this manual,
use the following guidelines for safe operation of the unit:
• Read all instructions before using equipment.
• Install or locate the equipment only for its intended
use as described in this manual. Do NOT use
corrosive chemicals in this equipment.
• Do NOT operate this equipment if it has a damaged
cord or plug; if it is not working properly, or if it has
been damaged or dropped.
• This equipment should be serviced by qualfied personnel only. Contact A.J. Antunes & Co. for repair.
• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
The following warnings and cautions appear throughout
this manual and should be carefully observed:
• Unplug the power cord before performing any
service or maintenance on the unit.
• All electrical connections must be in accordance
with local electrical codes and any other applicable
codes.
• WARNING ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN SERIOUS INJURY OR DEATH.
- Do NOT modify the power supply cord plug. If
it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
- Do NOT use an extension cord with this unit.
• If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or a similarly qualified person.
• This equipment is to be installed to comply with the
local plumbing code and any other applicable code.
• Water pressure must not exceed 100 psig (690
kPa). To reduce water pressure, install a water
pressure regulator and set water pressure to suit
application.
• The trans membrane pressure (inlet water pressure minus the permeate water pressure) must not
exceed 45 psi (310 kPa).
• System should be supplied only with cold water.
• Commonwealth of Massachusetts Plumbing Code
248 CMR shall be adhered to. The use of saddle
valves are not permitted, please consult your local
plumber.
• A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system
• When installed on metallic plumbing, a properly
sized electrical bonding jumper must be installed
across the inlet and outlet pipes serving this device.
4
P/N 1011135 Rev. C 10/15
UF-216CC WATER FILTRATION SYSTEM
SPECIFICATIONS
Electrical RatingsDimensions
Model &
Mfg. No.
UF-216CC
9700407
A
Electrical Cord & Plug Configurations
Voltage Watts Amps Hertz
100‒240 10 0.8 50/60
B
Model &
Mfg. No.
UF-216CC
9700407
Width
(A)
14”
(26 cm)
Depth
(B)
7”
(18 cm)
Replacement Cartridges
Replacement Cartridge Part No.
C
Height
(C)
26”
(66 cm)
Kit Model
Number
0012146
Description Configuration
DC Power Supply
100 - 240 VAC
Includes the
4 plug adaptors
below
NOTE: PLUG STYLE
MAY VA RY
US
NEMA 1-15 (2 pin)
or NEMA 5-15
(3 Pi n)
Euro
CEE 7/16
AS/NZS
3112
AUS
(2 Pi n)
UK
BS 1363
UF-216CC Ultra Filter Cartridge 2090162
UF-216CC Carbon Element 7001103
Ultra Filter Cartridge Capacities
Max.Operating Pressure 100 psig (690 kPa)
Max. Operating Temp. 100°F (38°C)
Min. Operating Temp. 40°F (4°C)
Max. Trans Membrane Pressure 45 psi (3.1 bar)
pH Range 3-10
MWCO 100 kD
P/N 1011135 Rev. C 10/15
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other
applicable codes.
A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system.
When installed on metallic plumbing, a properly
sized electrical bonding jumper must be installed
across the inlet and outlet pipes serving this
device
5