Survey Instructions and Form
Find and Measure
1. Find the serial plate of the case and
record the following information on the
Commercial Refrigeration Swing Door
Retro-fit Survey Information Form on
page 7:
a. Case Manufacturer
b. Case Model
c. End Panels
d. End Panel type
Figure 1 Cooler/Freezer Retrofit DoorReversible
e. Contour
2. Measure the overall length of the lineup
and record the following information on
the Commercial Refrigeration Swing
Door Retro-fit Survey form on page 7:
a. If the cases are in one single lineup,
measure the inside dimension of
the overall length from end to end.
b. If there are several cases, but not in
a lineup together, measure the
inside dimension of the overall length from end to end of each case
or section individually.
3. Measure the height of the opening and record the following information
on the Commercial Refrigeration Swing Door Retro-fit Survey Information
Form on page 7:
a. Measure the opening height (B) refer to Figure 1, every 4-6 feet of the
lineup. Cases can very for many reasons, so we are looking for the
widest, narrowest, and average opening height so that we can deter
mine the best net opening and door size to use.
b. Do this for each case or lineup the retrofit is being considered.
-
5/27/272010 2 A0146_A

Survey Instructions and Form
View/measuring the offset
Hanging the plum line
4. Measure the Canopy offset as compared to the handrail and record the
following information on the
Survey Information Form on page 4:
Hang a plum line or straight edge from the canopy so that the distance can be measured from the canopy to the handrail (D) refer to
Figure 1.
5. Measure the distance from the floor to the top of the handrail (A) refer to
Figure 1, and record the following information on the Refer to “Commerical Refrigeration Retro-fit Survey Information Form on page 4.
6. Measure the height/thickness of the canopy (C) refer to Figure 1, and
record the following information on the Refer to “Commerical Refrigera-
tion Retro-fit Survey Information Form on page 4.
Refer to “Commerical Refrigeration Retro-fit
7. Evaluate the end panels:
a. Note if the end panels are straight or contoured.
If contoured, a trace must be made. Do this by sliding a full length
sheet of butcher paper or equivalent between the panel and the case
and trace the contour with a pen or pencil onto the paper. This should
be returned to Anthony International with this completed survey.
b. Another option is to have an end panel made. If the end panel is
easily removable, this is a better option then trying to fill in or match
a contour.
8. Photograph the lineup(s):
a. Take detailed pictures of all items measured on the case. Take both
close ups and full view pictures.
b. Take pictures of ALL end panels.
c. Take pictures of any lighting and incoming electrical connections.
Note where the power come in.
d. Photograph the lineup as if you are standing on the end, looking down
the lineup.
e. Photograph underneath the canopy, if possible.
5/27/272010 3 A0146-A

Case Manufacturer:
Case Model:
End Panels :
Yes or No
End Panel type:
Solid
or Contour
Retrofit type 1 = Continuous Common door size Line-up
Number of cases= (from left to right) Case
width =
#1
#2 #3 #4 #5 #6
# 7
#8 #9 #10 #11 #12
Total N.O. width=
N.O. Height =
AI Door Model requirement:
Model:
Type of application: NT or LT
Number of doors:
Other standard order information requirements: Finish, Lights, Shelving, wire exit location, etc…
Retrofit type 2 = Per case width multiple door size Line-up
Number of cases= (from left to right) Case
width =
#1
#2 #3 #4 #5 #6
#7 #8 #9 #10 #11 #12
Each case N.O. width=
#1
#2 #3 #4 #5 #6
#7 #8 #9 #10 #11 #12
AI Door Model requirement:
Model:
Type of application NT/LT: # of doors per
case section:
#1
#2 #3 #4 #5 #6
#7 #8 #9 #10 #11 #12
Other standard order information requirements: Finish, Lights, Shelving, wire exit location, etc…
Case dimensional information (See Figure 1. Cooler/Freezer Retrofit Door Reversible)
Opening Height (B) Floor Handrail (A)
Canopy Offset (D) Canopy thickness (C)
Submit Query
Survey Instructions and Form
Commerical Refrigeration Retro-fit Survey Information Form