80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
6-3 Amps
50-60 Hz
500 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 9.22%, 50% Load)
0.56 0.94 16.06% 10% 61.35 12/0.02 3.34/0.98 5.06/0.98 5.04/0.2 51.18 83.42%
1.03 0.98 10.83% 20% 115.90 12.01/0.05 3.34/1.96 5.08/1.95 5.02/0.41 102.76 88.67%
2.54 0.98 9.22% 50% 286.40 12.17/0.12 3.32/4.9 5.14/4.86 4.98/1.02 258.40 90.22%
5.23 0.99 7.38% 100% 595.90 12.7/0.24 3.3/9.8 5.23/9.7 4.9/2.03 521.36 87.49%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current