Disposal of Electronic Equipment WEEE Directive 2002/9
Description – Disco Bulkhead, 16Watt 2D / 28Watt 2D
® Installation Instructions
Luminaire Code(s) – ADI16 & ADI28
General Installation Instructions
These instructions should be read carefully prior to any installation and retained after completion for further
reference and maintenance. Please give these instructions to the building owner/occupier after installation.
Important Safety
1. Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and the circuit
supply fuses are removed or the circuit breaker is turned off.
2. It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the luminaire is
installed in compliance with the current edition of the IEE Wiring Regulations.
3. The person carrying out the installation is to check and verify that the total load on the circuit, including that of this luminaire does
not exceed the rating of the circuit cable, fuse or circuit breaker.
4. Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful sizing to
avoid nuisance tripping of the protective device used in the installation.
5. Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions are of a
suitable size for the luminaire being installed.
Ratings
1. All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
2. All luminaires carrying the “F” mark are suitable for installation on to normal flammable surfaces.
3. All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed.
4. All luminaires are designed to operate at 230Volts AC +10% / -2% = 225Volts to 253Volts. Do not operate outside these voltages
5. All luminaires are only suitable for applications within their rated Ingress Protection limits as stated.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
INSTALLATION
• Remove the diffuser from the base by turning 45 degrees anti-clockwise and pulling away from the base of the luminaire.
• Remove the CFL lamp by pulling away from the gear tray, care should be taken not to use undue force and not to pull
using the glass of the CFL lamp.
• Loosen but do not remove the gear tray retaining screws.
• Adjust the position of the gear tray to align the hole in the keyhole slots with the retaining screws, and remove the gear tray
from the base.
• Select a suitable cable entry point provided or by drilling into the base.
• Position and fix the base to a suitable solid surface using screws supplied.
• Pass supply cable into the luminaire through previously selected opening ensuring that the hole is smooth or a grommet is
fitted.
• Secure the supply cable by way of the cable clamp in the base of the fitting.
• Terminate the cable into the terminal block mounted on the underside of the gear tray ensuring correct polarity is observed
and the luminaire is earthed and any bare conductors are sleeved.
• Replace the gear tray by aligning the holes in the keyhole slots with the retaining screws on the base, adjust the gear tray
so the retaining screws now are aligned with the slots of the keyhole slots, re-tighten the retaining screws.
• Plug the lamp into the lamp holder on the gear tray.
• Re-fit the diffuser by placing over the base and turning anti-clockwise until it locks into position.
• Restore the mains supply, switch on and test for satisfactory operation.
IP44
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Maintenance:
1. Where applicable, it is important to ensure failed lamps are replaced immediately in order to prevent damage to the control gear.
2. Always replace lamps with the same lamp type and wattage as supplied. When replacing Metal Halide Lamps it is important to
note that there are different types of Metal Halide Lamps and some types of lamps will not be suitable for use with the control gear
fitted within this luminaire. If you are in doubt, please contact your equipment supplier or Ansell Lighting for further advice.
Blue / Black
Brown / Red
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
This product falls within the scope of the Waste Electrical & Electronic Equipment Directive
(WEEE), which means the product should not be disposed of as normal household waste.
Ensure that this luminaire and lamp is disposed of in accordance with the WEEE Directive.
Contact a local Council Waste Dept. Local Amenity Site, or the DTI for further information.
RoHS - All components and materials used in this product are RoHS 2002/95/EC compliant.
www.anselluk.com Issue Date: pd 20070413