Keep user’s guide for future reference. Please read the warnings and
safety instructions carefully before assembling & using the product.
Failure to follow the warnings and the instructions could result in serious
injury or death or damage to the product.
IMPORTANT INTENDED USE
is product is NOT intended and should NOT be used to prevent Sudden Infant Death Syndrome (SIDS).
is product is NOT intended to diagnose, treat, mitigate, cure or prevent any disease or condition.
is is a product to monitor the movement of healthy babies and is not a substitute for parental care.
is baby monitor is compliant with all relevant standards regarding electromagnetic fields and is,
when handled as described in the User’s Guide, safe to use
WARNINGS
1. Because of the serious strangulation risk to infant & toddlers, parents & careg ivers should
note the following Warnings
WARNING
- Strangulation Hazard –
Children have STRANGLED in cords
• KEEP the Nursery Unit and adaptor cords OUT of the
reach of children more than 3 feet or 1 metre away
• NEVER use extension cords with adaptors. ONLY use
adaptors provided
• is product is NOT a Toy. NEVER allow children to
play with it
2.
WARNING
- MOVEMENT SENSOR PAD - NO ALARM
• Sources of vibration & movement, other than your baby’s, can be detected by
the Sensor Pad and interfere with the performance of your Angelcare monitor
• e alarm will not sound if it detects movement other than your baby’s
• High sensitivity settings can pick up other sources of vibration & movement please read instructions on sensitivity setting to adjust accordingly
• Other active and older babies (toddlers) in the same room can be detected and
the alarm will not sound
• Ensure the baby’s environment is FREE from any movements or vibrations when
using the Sensor Pad - see below warnings 3 to 11
3. DO NOT use a cot mobile and other cot accessories
that may produce movements or vibrations
4. Fans (including ceiling), washing machines, floor
boards, central heating or loud music are all forms
of movement and vibration and may interfere and be
detected by the Sensor Pad
5. If an additional Nurser y Unit is added then it
must be positioned at least 2 metres minimum from
Nursery Unit 1 and Sensor Pad as this could interfere
with performance
6. DO NOT use with bedside cot touching parent’s/
carer’s bed as the S ensor Pad will detect your
movements
7. DO NOT place the co t against a wall or skirting
board as vibra tions may be detected
8. Following removal of baby from the cot, some
mattresses may still de tect mattress movement
due to it forming back in to shape and alarm may not
sound
9. Ensure cot is stable to eliminate any movement
2
2
10. Cot should not be placed in reaching distance of
another cot or bed
11 . DO NOT use o ther wireless devices in the same
room as the monitor (including mobile phones,
microwaves...). ey may interfere with signal and
performance
12 . e Sensor Pad is made of plastic and does
not permit air to circulate. erefore, mildew
build up could develop underneath the mattress in
the Sensor Pad area
We suggest rotating & airing /dr ying the mat tress
regularly to prevent any mildew. AVOID CONTACT WITH MOISTURE. Clean - wipe with a dry lint free
cloth
13. e Sensor Pad is not suitable for use
above age 24 months
• is product is designed to aid in the monitoring of
your child. When using the monitor, you must still
provide the supervision necessary for the continued
safety of your child
• Use this appliance ONLY for its intended use as
described in this manual
15. e Sensor Pad is not intended to be used
to determine if a child is out o f the cot
16. ALWAYS be sure to immediately check on
baby whenever an alarm sounds
17. Keep cords out of the reach of ANY
children
18. ONLY use the chargers and power
adaptors provided. Do not use other types as
this may damage the device and battery pack
(if included in your model)
19. Adult assembly required. Keep small parts
away from children when assembling
20. Follow instructions and test this monitor
and its functions so you are familiar with it
prior to actual use. ALWAYS be sure that both the
transmitter and receiver are working properly and
are within range of each other – check periodically
and when changing location of the Nurser y Unit
21 . DO NOT touch the plug contacts especially
with sharp or metal objects
22 . DO NOT use the baby monitor near water
Care should be taken so that objects DO NOT fall
onto units and that liquids are not spilled into either
unit or Sensor Pad through i ts openings
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
23. Keep monitor AWAY from heat sources
(such as stoves, radiators, etc.). Hea t can
damag e the case or electrical par ts
24. ALWAYS place both the Nursery Unit and
the Parent Unit on a flat solid surface in
an upright position that allows for proper
VENTILATION. DO NOT place on sofas, cushions,
beds, e tc. which may block ventilation or anywhere
that would muffle the sound or interfere with the
normal flow of air
25. e baby monitor can only be used
between 10°C and 40°C (50°F and 10 4°F)
WARNINGS AND SAFETY
INSTRUCTIONS BATTERY
SPECIFIC
26. A LWAYS keep all batteries away from
children
27. e Parent Unit battery is a replaceable
Li-Ion battery. e Wireless Sensor Pad uses
a replaceable Button Cell Lithium Battery.
Only use the Angelcare recommended
replacement bat tery (see Technical
Specification)
• Danger of explosion if the wrong battery is used
or if replaced incorrectly. Refer to User’s Guide for
correct battery installation
• DO NOT short circuit supply terminals
28. DO NOT mix old and new batteries and only
use Angelcare recommended replacement
batteries (see Technical Specification)
29. is product contains a Button Cell Battery
and if swallowed can cause internal chemical
burns in as little as two hours and lead to
death. Dispose of used batteries immediately.
Keep new and used batteries away from
children. If you think batteries might have
been swallowed or placed inside any of the
body, seek medical attention.
30. e Button Cell Batter y represents a small
part and a choking hazard – KEEP away from
children!
31. Exercise care in handling batteries in order
not to short out the batteries with conduc ting
materials such as rings, bracele ts and keys
32. Overcharging, short circuiting, reverse
charging, mutilation, or incineration of
batteries must be avoided to prevent one or
more of the following occurrences: release of toxic
materials, release of hydrogen and/or oxyg en, g as
and rise in surf ace temperature
33. DO NOT attempt to recharge batteries
provided with or identified for use with this
product that are no t intended to be charged
e batteries may leak corrosive electrolyte or
explode
34. Incorrect polarity installation of the
batteries in the end product must be avoided
Reverse insertion of batteries can cause charging,
and that may result in leakag e or explosion
35. Remove batteries from units if you store
the product over 30 days because the batteries
could leak and damage the product
36. Discard ‘dead’ bat teries as soon as possible
since ‘dead’ batteries are more likely to leak in a
product. If a battery has leaked or vented, discard
product responsibly
37. DO NOT store this produc t, or the
batteries provided with or identi fied for use
with this product, in hig h-temperature &
high humidity environments and avoid direct
sunlight
IMPORTANT SAFETY INSTRUCTIONS
38. Sensor Pad –
• If your cot does not have a solid, stationary,
completely flat, firm surface including a spring or
slat base, place a hard board between the cot base
and the Sensor Pad, to ensure correct operation
(see specification on STEP 2)
• e Sensor Pad functions with standard cot sprung
and foam mattresses and not memory foam (partial
or full), hollow frame construction mattresses and
water beds. Please consult Angelcare if unsure of
mattress compatibility
39. is monitor uses public airwaves to transmit
signals. e Parent Unit may pick up signals or
inter ference from other nursery monitors in your
3
3
E
E
N
N
area. Your monitor may even be picked up by o ther
households. To protec t your privacy, make sure both
units are turned OFF when not in use
40. Power cord protection - Protect the
Adaptor’s power cord from being walked on
or pinched by furniture or other items – Power
supply cords should be routed so that they are not
likely to be walked on or pinched by items upon or
against them, paying par ticular at tention to cords
and plug s, convenience receptacle, and the point
where they exit from the product . e socket ou tlet
should be installed near the equipment and should
be easily accessible. Make sure to plug the adaptor
to the socket outlet nearest to the equipment and
that is easily accessible. To disconnect from mains,
unplug the adaptor
41. Only use attachments/accessories
and replacement parts specified by the
manufacturer. Any mounting of the product
should follow the manufacturer’s instructions
• DO NOT position this product on an unstable cart,
stand, tripod, bracket or table. e product may fall,
causing serious injury to a child or adult and serious
damage to the product
• Use ONLY the stand sold with the product
SET UP REQUIREMENTS
• Be sure replacement parts are supplied by Angelcare
and have the same characteristics as original
part. Unauthourised substitution may result in fire,
electric shock or fire
42. Unplug this appliance during lightning
storms or when not used for long periods of
time
43. Servicing - DO NOT attempt to service
this product yourself as opening or removing
covers (except battery door) may expose you
to dang erous voltage or other hazards
• Power Supply – see Technical Specification within
this guide
44. Overloading - DO NOT overload wall
outlets, extension cords or integ ral
convenience receptacles as this can result in a
risk of fire or electric shock
45. Nursery Unit Antenna - e antenna used
for this transmitter must be installed to provide a
separation distance of at least 8’’ (20 cm) from all
persons and must not be collocated or operating in
conjunction with any other antenna or transmitter
46. Cleaning - Disconnect all units before cleaning.
DO NOT immerse any part of the monitor in water.
Clean only with a dry cloth
WHAT’S IN THE BOX
1
Nursery Unit
2
Stand (for Nursery Unit)
3
2 x AC Adaptors
4
Parent Unit
5
Lithium Ion Battery Pack
(for Parent Unit)
6
Sensor Pad (on model AC327
and AC337)
7
CR2450 Battery (for Sensor Pad)
(on model AC327 and AC337)
8
Hardware (for wall mounting)
WHAT YOU NEED
Hardboard, if the cot does not have
a firm surface
(see specification on STEP 2)
4
1
2
3
2X
4
5
6
7
8
1 SETTING UP THE PARENT UNIT
2
1
3
Charge the Parent
Unit 8 hours
8H
prior to first use
Regular charging time
is 4 hours
2 SETTING UP THE SENSOR PAD ON MODEL AC327 AND AC337
e Sensor Pad is designed to detect subtle baby movements on the surface of the
mattress.e alarm will only sound if NO movement is detected for 20 seconds.
1
2
1. Remove the battery cover
and insert the battery face
with + face up
2. Replace the battery cover,
align 2 dots and click to secure
E
N
3
3. Remove the mattress from
the cot, place Sensor Pad
- Angelcare® logo side
up - on base in approximate
centre of mattress. It should
be centred on the hardboard if
your cot requires a hardboard
support (see ‘IMPORTANT’ note
below)
4. Replace the mattress
Correct positioning
for slatted base
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.