Angelcare AC1100 User Manual

5 (1)
FOR YOUR PEACE OF MIND
OWNER’S MANUAL
DIGITAL VIDEO, MOVEMENT & SOUND BABY MONITOR
Model AC1100
IMPORTANT ADVICE FOR INITIAL SETUP
Your monitor comes with the movement alarm activated. When switching on your monitor it will alarm, with or without the Sensor Pad plugged in, if no movement is detected. Deactivate the movement function to use the monitor without the Sensor Pad.
DON’T
FORGET
Batteries
Insert the enclosed rechargeable batteries into the Parent Unit. If inserted incorrectly the Parent Unit will not charge when placed in the charging cradle. The battery icon will flash briefly on the Parent Unit screen to indicate charging.
Cord Safety
Ensure the Nursery Unit is at least 1 metre away from your baby’s cot. The Sensor Pad cord must always be kept out of reach of baby and secured using the cord cover kit provided.
PLEASE FOLLOW THE INSTRUCTIONS CAREFULLY FOR CORRECT SETUP
Please DO NOT return this product to the store. For assistance please
contact our helpline on 0845 009 1789 or email helpline@babyhelpline.co.uk Mon – Fri 10am – 4pm, excluding bank holidays.
TABLE OF CONTENTS
WARNINGS .................................................................................. 3
AC1100 SETUP REQUIREMENTS .................................................. 8
STEP 1 - Charging the Parent Unit ............................................... 9
STEP 2 - Installing the Sensor Pad ............................................ 10
STEP 3 - Setting up the Nursery Unit ........................................13
STEP 4 - Turning on your Monitor ..............................................14
STEP 5 - Testing and getting to know your Monitor ............15
STEP 6 - Activating and deactivating
additional functions .......................................................19
Troubleshooting ...............................................................................25
Limited warranty ..............................................................................27
Technical specifications .................................................................28
OWNER’S MANUAL
KEEP YOUR OWNER’S MANUAL FOR FUTURE REFERENCE.
PLEASE READ THE WARNINGS AND INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING & USING THE PRODUCT.
FAILURE TO FOLLOW THE WARNINGS AND THE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH OR DAMAGES TO THE PRODUCT.
THE SENSOR PAD FEATURE IS NOT FOR USE WITH ADULTS, CHILDREN OR INFANTS OLDER THAN 24 MONTHS.
THE SENSOR PAD IS NOT INTENDED TO BE USED TO DETERMINE IF A CHILD IS OUT OF THE CRIB.
WARNING
Adult assembly required. Keep small parts away from children when assembling.
This Angelcare Monitor is a Personal Care Product. Please DO NOT return this to the store where you purchased it from. If you have any questions or require assistance please call the Angelcare Helpline on 0845 009 1789 or email helpline@babyhelpline.co.uk.
The Baby Helpline is open Monday to Friday, 10am to 4pm. The helpline is closed on bank holidays.
For additional FAQs and to download instruction manuals visit; www.angelcare.co.uk. To order spare parts for your Angelcare Baby Monitor visit; www.megababy.co.uk.
WARNINGS
1. THIS PRODUCT CANNOT REPLACE
RESPONSIBLE ADULT SUPERVISION. This product is designed to aid in the monitoring of your child. When using the monitor, you must still provide the supervision necessary for the continued safety of your child. Monitoring of premature babies, or those considered to be at risk, should always be carried out under the supervision of a health professional. This monitor SHOULD NOT be used as a medical device, nor as a device to prevent Sudden Infant Death Syndrome (SIDS).
WARNING Strangulation Hazard —
2.
Children have STRANGLED in cords. Keep
use. Immediately discontinue use of Sensor Pad(s) if protective covering is damaged or broken.
3. Never use extension cords with AC adapters. ONLY use the AC adapters provided.
4. When an AC Adapter is plugged into an elec trical outlet, DO N OT touch the exposed end.
5. ALWAYS be sure tha t both the transm itter and receiver are working properly and are within range of each other. Test monitor before first use, periodically and when changing location of the Nursery Unit.
6. ALWAYS be sure to immediately check on baby whenever an alarm sounds.
7. DO NOT use monitor near water (such as bath tub, sink, etc .).
adapter cords out of the reach of children (more than 1 m away). NEVER use Sensor Pad(s) without the protective cord covering. Check protective cord covering before each
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
8. Keep monitor AWAY from heat sources (such as stoves, radiators, etc.).
9. ALWAYS place both th e Nursery Unit and Parent Unit on a flat surface in an upright position and allow for proper ventilation. DO NOT place on sofas , cushions, beds, etc. which may block ventilation.
10. This monitor uses public air waves to transmit signals. The Parent Unit may pick up signals or interfere nce from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use. If you experience interference, change the channel on both units.
11. This product is NOT a toy. DO NOT allow children to play with it.
12. This product contains small parts. Adult assembly required. Exercise care when unpacking and assembling the product and keep small parts away from children.
13. When using the monitor, the room temperature should be between 50°F (10°C) and 104°F (40°C).
BATTERY WARNING
14. Use ONLY AAA RECHARGEABLE
batteries for the Parent Unit. DO NOT mix old and new batteries. DO NOT mix alkaline, standard or rechargeable batteries. Insert batteries with correct polarity. DO NOT short-circuit supply terminals. ONLY use the recommended batteries or equivalent (volts and size) and the correct adapter. Remove batteries when product is stored for long periods of time or when batteries are exhausted. Dispose exhausted batteries properly. DO NOT recharge non-rechargeable batteries. Rechargeable batteries are ONLY to be charged under adult supervision. Keep all
UK0614
32
batteries away from children.
15. IMPORTANT SAFETY INSTRUCTIONS
15.1 Read these instructions - All the safety
instructions should be read before the product is operated.
15.2 Keep these instructions. The safety and ope rating instructions should be retained for future reference.
15.3 Heed all warnings – All warnings on the product and in the operating instructions should be adhered to.
15.4 Follow all instructions – All operating and use instructions should be followed.
15.5 Water and moisture - DO NOT use this apparatus near water. For example, near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet environment or near a swimming pool and the like. C are should be taken so that objects DO NOT fa ll onto units and that liquids are not spilled into either unit or Sensor Pad through its openings.
15.6 Cleaning - Disconnec t all units before cleaning. DO NOT immerse in water any part of the Nursery Unit, Parent Unit. Clean only with dry cloth. DO NOT spray with cleaning products or solvents. Wipe Sensor Pad with a cloth moistened very slightly with an antiseptic or mild detergent.
15.7 Ventilation - DO NOT block any ventilation openings. Allow for proper ventilation when units are in use. DO NOT cover the Nursery Unit or Parent Unit with any object such as a blanket. DO NOT place it in a drawer or in any location which would muffle the sound or interfere with the normal flow of air.
15.8 Heat sources - DO NOT install near any heat sources such as radiators, heat registers, stoves, TVs or other apparatus (including amplifiers) that produce heat. Heat can damage the case or electrical parts.
15.9 Power cord protection - Protect the Sensor Pad cord and Adapter’s power cord from being walked on or pinched by furniture or other items – Power supply cords should be routed so that they are not likely to be walked on or pinched by items upon or against them, paying particular
attention to cords and plugs, convenience receptacle, and the point where they exit from the product.
15.10 Accessories - Only use attachments/ accessories specified by the manufacturer. DO NOT place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious injury to a child or adult and serious damage to the product. Use ONLY with a cart, stand, tripod, bracket or table recommended by the manufacturer or sold with the product. Any mounting of the product should follow the manufacturer’s instructions.
15.11 Unplug this appliance during lightning storms or when not used for long periods of time.
15.12 Ser vicing - DO NOT attempt to service this product yourself as opening or removing covers (except battery doors) may expose you to dangerous voltage or other hazards.
15.13 Replacement parts - When replacement parts are required, be sure the replacement parts specified by the manufacturer have the same characteristic as the original part. Unauthorized substitution may result in fire, electric shock or other hazards.
15.14 Usage - This baby monitor is intended as an aid. It is NOT a substitute for responsible and proper adult supervision and should not be used as such. Use this appliance ONLY for its intended use as described in this manual.
15.15 Power S ources - Operate this product only from the type of power source indicated on the type plate of the adaptor. power supply to your home, consult your
If you are unsure of the type of
dealer or local power company.
15.16 Overloading - DO NOT overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or elec tric shock.
15.17 Object and Liquid Entr y - NEVER push objects of any kind into this produc t through casing slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. NEVER spill liquid of any
kind on the product.
15.18 Antenna - The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.9”) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
15.19 Power Lines - An outside antenna system should NOT be located in the vicinit y of overhead power lines or other electric light or power circuit, or where it can fall into such powe r lines or circuits as contac t with them may be fatal.
WARNING Strangulation Hazard —
15.20
Children have STRANGLED in cords. Keep
adapter cords out of the reach of children (more than 1 m away). NEVER use Sensor Pad(s) without the protective cord covering. Check protective cord
covering before each use. Immediately discontinue use of Sensor Pad(s) if protective covering is damaged
or broken.
15.21 I nterferen ce - This monitor u ses public airwaves to transmit signals. The Parent Unit may pick up signals or inter ference from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned O FF when not in use. If you experience interference, change the channel on both units.
15.22 Vibration Source - When the monitor is in use, DO NOT use a crib mobile or other crib accessories that may produce vibrations. Other sources of vibrations may include fans, washing machines, loud music, etc. These sources of vibration may interfere with the performance of your Angelcare not sound if it continues to detect any
®
monitor and the alarm will
movement other than your baby’s. Be sure all vibration sources are eliminated before using the monitor.
You may experience false alarms for several reasons. The most common reason is the Nursery Unit has not been turned OFF after you have removed your baby from the crib. Another reason is the Sensor Pad has not
been placed under the mattress properly.
Be sure the Sensor Pad is on a flat, firm surface with the printed side facing up. The sensitivity level may also need to be adjusted. Refer to step 5.1.
15.23 Sensor Pad - Your Sensor Pad can be used in any crib that is stationary. If the crib has a spring or slat base, place a hard board between the crib base and the Sensor Pad measuring at least 13” x 13” (33 x 33 cm) and 1/4 inch (6 mm) thick. Only use your Angelcare stationary sleeping environment such as
®
monitor in a
a crib where the Sensor Pad can rest on a completely flat, firm surface.
54
16. IMPORTANT SAFETY INSTRUCTIONS RELATED TO USE OF BATTERIES
16.1 Use ONLY the type and size of
batteries specified in the owner’s manual. There is a risk of explosion if batteries are replaced with an incorrect t ype.
16.2 Use ONLY AAA rechargeable batteries and/or the AC Adapters provided for the Parent Unit. You must use only rechargeable batteries in the Parent Unit. DO NOT use alkaline batteries or you will severely damage the unit.
16.3 Charge the batteries for 15 hours prior to first use. Be sure to have the monitor in the OFF position during this period. ONLY use the AC Adapters included with your monitor.
16.4 DO NOT use these adapters with any other equipments.
16.5 When unplugging the AC Adapter from the N urser y Unit, be sure it is switched to the OFF position. If it isn’t, the unit will revert to battery mode if batteries are installed.
16.6 DO NOT use rechargeable batteries in the Nursery Unit. Use alkaline batteries ONLY.
16.7 DO NOT dispose batteries in fire. They may explode. Check with local regulations for possible special disposal instructions.
16.8 Exercise care in handling batteries in order not to short out the batteries with conducting materials such as rings, bracelets and keys . Overcharging, short circuiting, reverse charging, mutilation, or incineration of batteries must be avoided to prevent one or more of the following occurrences: release of toxic materials , release of hydrogen and/or oxygen gas, rise in surface temperature.
16.9 DO NOT attempt to recharge batteries provided with or identified for use with this product that are not intended to be charged. The batteries may leak corrosive electrolyte or explode.
16.10 DO NOT attempt to rejuvenate the batteries provided with or identified for use with this produc t by heating them. Sudden release of battery electrolyte may occur, causing burns or irritation to eyes or skin.
16.11 If and when necessary, the batteries must be replaced with identical new ones or equivalent (volts and size). If a battery to be replaced is connected with other batteries in series, replace the other batteries at the same time as well. DO NOT mix old and new batteries.
16.12 Reverse polarity installation of the batteries in the end product must be avoided. Reverse insertion of batteries can cause charging, and that may result in leakage or explosion.
16.13 Remove batteries from this product if you store the produc t over 30 days because the batteries could leak and damage the product.
16.14 Discard ‘dead’ batteries as soon as possible since ‘dead’ batteries are more likely to leak in a product. If a battery has leaked or vented, it should be replaced immediately using protective gloves.
16.15 DO NOT store this product, or the batteries provided with or identified for use with this product, in high-temperature are as.
WARNING
(North America Only)
17.1 Modifications not authorized by the
manufacturer may void users authority to operate this device.
17.2 NOTE: This equipment has been tested and found to comply with part 15 of the FCC Rules and the Industry Canada licence­exempt RSS standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
17.3 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between
the equipment and receiver.
• Connect the equipment into an
outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced
radio/TV technician for help.
FCC AND IC REGULATIONS
17.4 This device complies with the part 15
of the FCC Rules and the Industry Canada licence - exempt RSS standards(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
RF radiation exposure statement
The Nursery Unit complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. Caution: To maintain the compliance with the FCC’s RF exposure guideline, install the Nursery Unit at least 20 cm from ALL persons. The transmitter of this device must not be co-located or operating in conjunction with any other antenna or transmitter.
Industry Canada
This product meets the applicable Industry Canada technical specifications. CAN ICES-3 (B)/NMB-3 (B)
76
SETUP REQUIREMENTS
6
5
4
32 1
6
5
4
32 1
Keep
at least
1 m.
IMPORTANT
INCLUDED:
VIDEO, MOVEMENT & SOUND MONITOR
Model AC1100
STEP 1 - CHARGING THE PARENT UNIT
1 2
IMPORTANT
Never use regular alkaline batteries in the Parent Unit; they may explode.
Rechargeable
Parent Unit
1 Sensor Pad (AC1100) or 2 Sensor Pads (AC1100-2SP)
with pre-installed cord covers
Nursery Unit Charging Cradle Belt Clip
YOU MUST PREPARE:
One hardboard (not included) Thickness: 6 mm Minimum dimensions:
33 cm x 33 cm
Maximum dimensions: equal to the mattress size
Hardboard
IMPORTANT
The hardboard must be larger than the Sensor Pad surface area.
BABY’S ROOM:
IMPORTANT
Place the crib near a supporting wall and far from air currents. Install the Nursery Unit on a flat, stable surface facing the crib at a distance of at least 1 meter.
3X
2X
2 AC Adapters
WHAT YOU WILL NEED (NOT INCLUDED):
3 Rechargeable
AAA Batteries
3X
3 AAA Alkaline
Batteries
Miniature Philips
Screwdriver
3 4
PARENT UNIT:
A
B
D
1) Remove the Belt Clip.
2) Remove the battery door and insert
the Rechargeable Batteries (included).
15
3) Connect the AC Adapter to the
Charging Cradle and into an electrical outlet.
4) Charge the unit for 15 continuous hours (prior to first use).
NOTE:
To optimize your battery performance please refer to Battery Guidelines in the Trouble Shooting section.
A) LCD Touchscreen
F
G
H
C
I
E
J
B) POWER ON/OFF
C) Microphone
D) Speaker
E) Charging Cradle
F) Belt Clip
G) Speaker
Volume Buttons
H) Talk Back Button
I) Battery Door
J) AC Adapter Outlet
(not shown)
Sensor Pad
Front Side Left Side
98
STEP 2 - INSTALLING THE SENSOR PAD
WARNING
6
5
4
32 1
Sensor Pad with pre-installed cord covers
Cord covers 1, 2, 3, 4:
Position on floor
Cord cover 4: Contains double sided tape to securely install beneath crib leg
Cord cover 5: Position vertically between mattress support and floor
Cord cover 6: Place under the mattress
2.2 - SELECT THE CRIB LEG YOU WILL BE USING TO SECURE THE CORD COVERS
RECOMMENDED
6
5
4
3
Fig 1
2
1
1) Use the crib leg by the wall closest to the Nursery Unit (fig 1). In cases where the Nursery Unit is across the room, use the leg closest to the Nursery Unit to position the covered wire (fig 2). It is always preferable that the covered cord run along a wall.
OR
6
STRANGULATION HAZARD.
Children have STRANGLED in cords:
•Keep adapter cords out of the reach of children (more than 1 m away).
•Because of the serious strangulation risk to infants and toddlers, parents and caregivers should never place the Nursery Unit within 1 meter of a crib.
•NEVER use Sensor Pad without the cord covers. Check cord covers before each use to ensure it is securely placed under the leg of the crib. Discontinue use of Sensor Pad if any cord covers are damaged or broken.
•NEVER use extension cords with AC adapters. ONLY use the AC adapters provided. This product is not a toy. Never allow children to play with it.
2.1 - SELECT A LOCATION FOR THE NURSERY UNIT
Select a location for the Nursery Unit that is at least 1 meter away from the crib.
IMPORTANT
Keep
6
at least
1 m.
5
4
3
2
1
2.3 - INSTALL THE SENSOR PAD ON THE MATTRESS SUPPORT
3
4
Fig 2
1) Remove the mattress from the crib.
5
6
4
3
2
1
2) Place the Sensor Pad - printed side up
- on top of the hardboard at the center of the crib.
3) Run the connection pin, warning label
and the first 5 cord covers down along the backside of the crib leg, between
the mattress support and the inside edge of the crib.
4) Bring the first 4 cord covers down
the floor, and keep the 5 vertically, along the backside of the crib leg, (between the mattress and the
inside edge of the crib).
5) Remove any cord slack to make sure
no parts of the cord are loose.
5
5
th
cord cover
5
4
32 1
1110
Loading...