Charging the Parent Unit (9 hours) ............................................................................................................................................4
Positioning the movement Sensor Pad .....................................................................................................................................5
Setting up the Camera ....................................................................................................................................................................7
Turning on your monitor ................................................................................................................................................................7
Getting to know your monitor......................................................................................................................................................9
Activating and deactivating additional functions ................................................................................................................12
01m5_Manuel_AC315_UK_12703.indd 12017-10-16 9:19 AM
OWNER’S MANUAL
KEEP YOUR OWNER’S MANUAL FOR FUTURE REFERENCE.
PLEASE READ THE WARNINGS AND INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING & USING THE PRODUCT.
FAILURE TO FOLLOW THE WARNINGS AND THE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH OR
DAMAGES TO THE PRODUCT.
THE SENSOR PAD FEATURE IS NOT FOR USE WITH ADULTS, CHILDREN OR INFANTS OLDER THAN 24 MONTHS.
THE SENSOR PAD IS NOT INTENDED TO BE USED TO DETERMINE IF A CHILD IS OUT OF THE COT.
WARNING
Adult assembly required.
Keep small parts away from children when assembling.
We, at Angelcare®, stand behind all of our products.
If you are not completely satisfied or have any questions,
United States and Canada: Please contact us at: angelcare@cdecinc.ca
Other countries: Please contact your local distributor.
WARNINGS
1. THIS PRODUCT CANNOT REPLACE RESPONSIBLE ADULT SUPERVISION.
This produ ct is designed to ai d in the monitoring of y our child. When
using the m onitor, you must still pr ovide the supervi sion necessar y for the
continue d safety of your chil d. Monitoring of pr emature babies , or those
conside red to be at risk, sh ould always be car ried out under t he supervis ion
of a health pr ofessional. Th is monitor SHOU LD NOT be used as a medi cal
device, no r as a device to prevent Sudd en Infant Death Syn drome (SIDS).
2. WAR NING Strangul ation Hazard — Chil dren have STRAN GLED in cords.
Keep adapt er cords out of the reac h of children (more than 1 m etre away).
NEVER u se Wired Sensor Pa d(s) without the protecti ve cord covering.
Check prot ective cord covering be fore each use. Imme diately discontin ue
use, peri odically and wh en changing loc ation of the Camer a.
6. ALWAYS be sure to im mediately check o n baby whenever an al arm
sounds.
7. DO N OT use monitor near w ater (such as bath tub, sin k, etc.).
use of Wired S ensor Pad(s) if
protective c overing is damage d or
broken.
3. Neve r use extension cor ds with
adapters . ONLY use the adapters
provid ed.
4. Wh en an adapter is plu gged into
an electr ical outlet, DO N OT touch
the expose d end.
5. ALWAYS be sure tha t both the
transmitter and receiver are working
properly a nd are within ran ge of each
other. Test the mon itor before first
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
8. Kee p monitor AWAY from heat source s (such as stoves , radiators, etc.).
9. ALWAYS place both t he Camera and th e Parent Unit on a flat s urface
in an uprig ht position and all ow for proper ventila tion. DO NOT place on
sofas, cu shions, beds , etc. which may bloc k ventilation.
10. Th is monitor uses pub lic airwaves to transmi t signals. The Par ent Unit
may pick up sig nals or inter ference from ot her nurser y monitors in you r area.
Your monitor may e ven be picked up by other h ouseholds. To prote ct your
privacy, ma ke sure both units are tu rned OFF when not in use .
11. Th is product is NOT a toy. DO N OT allow children to pl ay with it.
12. T his product cont ains small part s. Adult assemb ly required. Exe rcise
care when unpacking and assembling the product and keep small parts
away from chil dren.
13. Wh en using the moni tor, the room temperat ure should be betwe en
10°C and 4 0°C.
BATTERY WARNING
14. Th e Parent Unit bat tery is a replacea ble Li-Ion batte ry. Only use the
Angelc are recommende d replacement ba ttery. Danger of exp losion if the
wrong batt ery is used or if rep laced incorrec tly. Refer to your user m anual
for correc t battery insta llation. DO NOT sho rt circuit suppl y terminals.
Only use th e Angelcare provi ded power adapter to c harge the batter y.
Remove the ba ttery from your Pa rent Unit if produc t is to be stored for
an extende d period of time. Disp ose of batteries ac cording to your loca l
ordinan ces. ALWAYS keep all batterie s away from children .
2
15. IMPORTANT SAFETY INSTRUCTIONS
15.1 H eed all warnings – All w arnings on the pro duct and in the ope rating
instruc tions should be ad hered to.
15.2 Follow all instru ctions – All opera ting and use instru ctions should
be followed.
15.3 Water and moisture - D O NOT use this appar atus near water. For
example, n ear a bath tub, wash b owl, kitchen sink , laundry tub, in a we t
environm ent or near a swimmi ng pool and the like . Care should be ta ken
so that obje cts DO NOT fall onto u nits and that liqui ds are not spilled into
either un it or Sensor Pad thro ugh its opening s.
15.4 Cleaning - Disco nnect all units b efore cleaning . DO NOT immerse in
water any par t of the monitor. Clean o nly with dry cloth .
15.5 Ventilation - DO NOT blo ck any ventilation o penings. Al low for proper
ventilatio n when units are in use . DO NOT cover the Camer a or the Parent
Unit with any o bject such as a bla nket. DO NOT place it in a d rawer or in
any locati on which would muf fle the sound or inte rfere with the nor mal
flow of air.
15.6 Heat sources - DO NOT i nstall near any h eat sources suc h as radiators,
heat regis ters, stoves, TVs or o ther apparatus ( including ampl ifiers) that
produce h eat. Heat can dam age the case or ele ctrical part s.
15.7 Power cord protectio n - Protect the Senso r Pad cord and
Adapter’s p ower cord from being w alked on or pinche d by furniture
or other ite ms – Power supply cord s should be routed so th at they
are not likel y to be walked on or pinch ed by items upon or ag ainst
them, payi ng particular a ttention to cords an d plugs, convenie nce
receptac le, and the point wh ere they exit from the p roduct.
The socket o utlet shall be inst alled near the equ ipment and shall b e easily
accessib le. Make sure to plug th e adapter to the socke t outlet nearest
to the equip ment and that is eas ily accessible. To disc onnect from mai ns,
unplug the adapter.
15.8 Accessories - On ly use attachme nts/accessories s pecified by the
manufac turer. DO NOT place thi s product on an uns table cart, st and,
tripod, b racket or table. T he product may fal l, causing serio us injury to
a child or ad ult and serious d amage to the produc t. Use ONLY with a
cart, stand, tripod, bracket or table recommended by the manufacturer
or sold with th e product. Any mo unting of the produ ct should follow th e
manufacturer’s instructions.
15.9 Unplug this app liance during lig htning storms or wh en not used for
long peri ods of time.
15.10 Servicing - DO NOT a ttempt to service th is product yours elf as
opening o r removing covers (except b attery door) may expo se you to
dangerous voltage or other hazards.
15.11 Replacement pa rts - When repla cement parts ar e required, be sur e
the replacement parts specified by the manufacturer have the same
charac teristic as the orig inal part. Una uthorized substit ution may result
in fire, el ectric shock or oth er hazards.
15.12 Usage - This baby mo nitor is intended a s an aid. It is NOT a sub stitute
for respon sible and prop er adult supe rvision and s hould not be use d as such.
Use this ap pliance ONLY for its inte nded use as descr ibed in this manua l.
15.13 Power Sources - Ope rate this product o nly from the type of p ower
source ind icated on the type pla te of the adaptor. If you are uns ure of the
type of powe r supply to your home , consult your deal er or local power
company.
15.14 Overloading - DO NOT ove rload wall outlet s, extension cord s or
integral co nvenience recept acles as this can re sult in a risk of fire or
electric shock.
15.15 Objec t and Liquid Entr y - NEVER push obj ects of any kind into th is
product t hrough casing sl ots as they may touch dan gerous voltage po ints
or short o ut parts that co uld result in a risk of f ire or electric s hock. NEVE R
spill liqu id of any kind on the pro duct.
15.16 Antenna - The anten na used for this tra nsmitter must be i nstalled
to provide a se paration distan ce of at least 20 cm from a ll persons and
01m5_Manuel_AC315_UK_12703.indd 22017-10-16 9:19 AM
must not be c ollocated or ope rating in conjun ction with any othe r antenna
E
N
or tr ansmi tter.
15.17 P ower Lines - An outsi de antenna system s hould NOT be locate d
in the vicin ity of overhead powe r lines or other ele ctric light or power
circuit, o r where it can fall int o such power lines or ci rcuits as contac t
with them may b e fatal.
15.18 Vibration Sourc e - When the monito r is in use, DO NOT use a b edside
crib, cot mo bile or other cot a ccessories th at may produce vib rations. Oth er
sources of vi brations may inc lude fans, wa shing machine s, loud music , etc.
These sou rces of vibration may i nterfere with the pe rformance of you r
Angelcare® monitor an d the alarm will not so und if it continues to d etect
any movemen t other than your baby ’s. Be sure all vibr ation sources are
elimina ted before using the m onitor.
15.19 You may experi ence false alarm s for several reason s. The
most comm on reason is the Cam era has not been tu rned OFF
after you hav e removed your baby from t he cot. Another rea son is
the Senso r Pad has not been pl aced under the ma ttress properly.
Be sure the S ensor Pad is on a flat , firm surface with th e Angelcare® logo
side faci ng up. The sensitiv ity level may also nee d to be adjusted. Ref er
to St ep 5.1. Always be sur e to immediately che ck on baby whenever a n
alarm sounds.
15.20 Sensor Pad - Your Se nsor Pad can be u sed in any cot that i s stationary.
If the cot has a s pring or slat ba se, place a hard b oard between th e cot base
and the Sen sor Pad measuri ng at least 33 x 33 cm an d 6 mm thick. Only
use your Angelcare® monitor in a s tationary sle eping environme nt such
as a cot where th e Sensor Pad can res t on a completely fla t, firm surface .
The Senso r Pad is made of plast ic and does not perm it the air to circulate .
Therefor e, milde w build up c ould deve lop und erneat h the matt ress in th e Sensor
Pad area. We su ggest rotatin g the mattress re gularly to prevent a ny mildew.
16. IM PORTANT SAFETY IN STRUCTIONS R ELATED TO USE OF BATTER IES
16.1 U se ONLY the type and s ize of battery spe cified in the own er’s manual.
There is a ris k of explosion if bat tery is replaced wi th an incorrect ty pe.
SETUP REQUIREMENTS
INCLUDED:
16.2 Charge the bat tery for 9 hours pri or to first use. Be su re to have the
monitor in th e OFF position during th is period. ONLY use th e adapters
included with your monitor.
16.3 DO NOT use these ada pters with any other e quipments.
16.4 When un plugging the a dapter from the C amera, be sure i t is switched to the OFF posit ion.
16.5 DO NOT dispose of bat teries in fire. Th ey may explode. Che ck with
local reg ulations for poss ible special dis posal instruc tions.
16.6 Exercise care in ha ndling batteri es in order not to shor t out the
batterie s with conductin g materials such as r ings, bracelet s and keys.
Overcharging, short circuiting, reverse charging, mutilation, or incineration
of batteri es must be avoided to pr event one or more of the fo llowing
occurren ces: release of t oxic materials , release of hydrog en and/or oxygen ,
gas and ris e in surface tempe rature.
16.7 DO NOT attempt to rejuve nate the batter y provided with or id entified
for use with th is product by heati ng them. Sudde n release of batter y
electro lyte may occur, causin g burns or irritati on to eyes or skin.
16.8 If and when nece ssary, the batter y must be replace d with identical
new ones or e quivalent (volts an d size).
16.9 Remove the batter y from the Parent Un it if you store the produ ct
over 30 days bec ause the batter y could leak and da mage the produc t.
16.10 Discard ‘dead ’ batteries as soon a s possible since ‘d ead’ batterie s
are more like ly to leak in a produc t. If a battery has l eaked or vented, it
should be r eplaced immed iately using protec tive gloves.
16.11 DO NOT store this prod uct, or the batte ry provided with or i dentified
for use with th is product, in hig h-temperature a reas.
Model AC315
Baby Video, Sound and
Movement Monitor
Hardware
(Screwdriver
required
for wall mounting)
AC adapter
(for Camera)
Touch control Parent Unit
Camera
AC adapter
(for Parent Unit)
Tabletop stand with
removable wall
mount metal ball
(for Camera)
Lithium ion
battery pack
(for Parent Unit)
Wired movement
Sensor Pad
* Always place
Angelcare logo side up *
6 Pre-threaded cord covers with
Split USB cable
3
01m5_Manuel_AC315_UK_12703.indd 32017-10-16 9:19 AM
STEP 1 - CHARGING THE PARENT UNIT (9 HOURS)
WARNING
1) Unlock the battery compartment
1
Battery compartment lock
2
Rear View
PARENT UNIT:
on the rear and remove the
cover. Insert the provided
rechargeable battery into the
compartment.
battery and the contacts in the
compartment must be aligned.
2) Connect the USB plug to the
Parent Unit and connect the power
adapter with an electrical outlet.
3) Charge the unit for 9 continuous
hours prior to first use.
Contacts of the
Power indicator
Power
On/Off
Main Menu
Microphone
Navigate back
Visual sound
indicator
Navigate Down
Confirm Selection
Front SideRear Side
Volume control +/-
(on the side)
Microphone
Navigate Up
Micro USB charging
port (on the side)
Rechargeable battery
compartment
Folding stand
(on rear)
STRANGULATION HAZARD.
Children have STRANGLED in cords:
• Keep adapter cords out of the reach of children
(more than 1 metre away).
• Because of the serious strangulation risk to infants
and toddlers, parents and caregivers should never
place the Camera within 1 metre of a cot.
• NEVER use Sensor Pad without the cord covers. Check
cord covers before each use to ensure it is securely
placed under the leg of the cot. Discontinue use of
Sensor Pad if any cord covers are damaged or broken.
• NEVER use extension cords with adapters. ONLY
use the adapters provided. This product is not a toy.
Never allow children to play with it.
4
01m5_Manuel_AC315_UK_12703.indd 42017-10-16 9:19 AM
STEP 2 - POSITIONING THE MOVEMENT SENSOR PAD
E
N
2.1 - SELECT A LOCATION FOR THE CAMERA
Camera can be installed on the wall (see included parts) or using the tabletop stand.
Depending on the position you choose, you’ll need to remove the metal ball from the stand
to wall mount Camera.
IMPORTANT
Place the cot near a supporting wall and far from air currents. Install the Camera on a
flat, stable surface facing the cot at a distance of at least 1 metre. Make sure to plug the
adapter to the socket outlet nearest to the equipment and that is easily accessible.
MUST BE MORE THAN
1 METRE AWAY
MUST BE MORE THAN
1 METRE AWAY
Sensor Pad
6
5
4321
OR
Sensor Pad
6
5
4321
6543 21
1) Insert jack 1 into the Sensor Pad and twist it clockwise to lock it.
2.2 - SELECT THE COT LEG TO SECURE THE CORD COVERS
RECOMMENDED
6
5
4
3
Figure 1Figure 2
2
OR
3
2
1
1
6
5
4
Use the cot leg by the wall closest to the Camera (Figure 1). In cases where the Camera is
across the room, use the leg closest to the Camera to position the covered wire (Figure 2).
It is always preferable that the covered cord run along a wall.
5
01m5_Manuel_AC315_UK_12703.indd 52017-10-16 9:19 AM
2.3 - INSTALL THE SENSOR PAD ON THE MATTRESS SUPPORT
8 cm
4132
4
3
2
1
IMPORTANT
If your cot does not have a solid, stable surface for the Sensor
Pad, you will need to place a support under it, to ensure correct
operation of the system.
This hardboard support should be at least 6 mm thick and should
have minimum dimensions of 33 cm x 33 cm. This support board
must be larger than the Sensor Pad surface area.
The Sensor Pad functions with any size and type of mattress except memory-foam
mattresses, hollow frame mattresses and water beds. The hardboard maintains a
constant pressure on the Sensor Pad, enabling it to detect the baby’s movements even
when the baby is at the edges of the cot.
2
Sensor Pad
5
4
6
3
3
2
1
1) Remove the mattress from
the cot.
2) Place the Sensor Pad –
Angelcare logo side up – on
top of the hardboard.
3) Run the connection pin,
warning label and the first
5 cord covers down along
the backside of the cot
leg, between the mattress
support and the inside edge
of the cot.
4) Bring the first 4 cord covers
4
5
down the floor, and keep
the 5th cord cover vertically,
along the backside of
the cot leg, between the
mattress and the inside
edge of the cot.
5) Remove any cord slack to
make sure no parts of the
cord are loose.
6
6) Place the 6th cord cover
approximately 8 cm from
the edge of the mattress
support.
Hardboard
7
CLICK!
7) Snap together the remaining
cord covers that will run
along the floor.
8) Remove any cord slack to
make sure no parts of the
89
cord are loose.
9) Peel off the double-sided
tape on the 4th cord cover
and place it securely under
the cot leg.
10) Check to make sure the
Sensor Pad has not moved
from position and place the
6
01m5_Manuel_AC315_UK_12703.indd 62017-10-16 9:19 AM
mattress back inside the cot.
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.