Ensure the Camera is at least 1 metre away from your baby’s
cot. The Sensor Pad cord must always be kept out of reach of
baby and secured using the cord cover kit provided.
For assistance, FAQs or guidance with your monitor
please visit our Customer Support page at angelcare.co.uk
STEP 1 - Charging the Parent Unit (9 hours) ...........................................................................................................................5
STEP 2 - Installing the Sensor Pad .............................................................................................................................................6
STEP 3 - Setting up the Camera ..................................................................................................................................................9
STEP 4 - Turning on your monitor ............................................................................................................................................ 10
STEP 5 - Testing and getting to know your monitor ........................................................................................................... 11
STEP 6 - Activating and deactivating additional functions ............................................................................................. 15
PLEASE READ THE WARNINGS AND
INSTRUCTIONS CAREFULLY BEFORE
ASSEMBLING & USING THE PRODUCT.
FAILURE TO FOLLOW THE WARNINGS AND THE
INSTRUCTIONS COULD RESULT IN SERIOUS
INJURY OR DEATH OR DAMAGES TO THE
PRODUCT.
THE SENSOR PAD FEATURE IS NOT FOR USE
WITH ADULTS, CHILDREN OR INFANTS OLDER
THAN 24 MONTHS.
THE SENSOR PAD IS NOT INTENDED TO BE USED
TO DETERMINE IF A CHILD IS OUT OF THE COT.
WARNINGS
1. THIS PRODUCT CANNOT REPLACE RESPONSIBLE ADULT SUPERVISION.
This prod uct is designe d to aid in the monitor ing of your child. W hen using
the monito r, you must still p rovide the s upervi sion nece ssary fo r the
continue d safety of yo ur child. M onitori ng of premat ure babies , or those
conside red to be at risk, sh ould always be ca rried out unde r the supervi sion
of a health pr ofession al. This monitor SH OULD NOT be u sed as a medical
device, no r as a device to prevent Sudd en Infant Death Synd rome (SIDS).
2. WAR NING Strangu lation Hazard — Ch ildren have STRA NGLED in cords .
Keep adapt er cords out of the reac h of children (more tha n 1 meter away).
NEVER u se Sensor P ad(s) without th e protective c ord covering . Check
protective c ord covering before ea ch use. Immediate ly discontinue use o f
location o f the Came ra.
6. ALWAYS be sure to im mediatel y check on ba by wheneve r an alarm
sounds.
7. DO N OT use monito r near water (su ch as bath tub , sink, etc .).
Sensor Pa d(s) if protective cov ering
is damaged or broken.
3. Neve r use extens ion cords wi th
adapters . ONLY use the ad apters
provid ed.
4. Wh en an adapt er is plugg ed into
an elect rical outl et, DO NOT tou ch
the expose d end.
5. ALWAYS be sure tha t both the
transmitter and receiver are working
properly a nd are within ran ge of each
other. Test the monitor before first
use, periodically and when changing
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
8. Kee p monitor AWAY from heat source s (such as stoves, radiato rs, etc.).
9. ALWAYS place both t he Came ra and the Pa rent Unit on a f lat surf ace
in an uprig ht position a nd allow fo r proper ven tilation . DO NOT place o n
sofas, cu shions , beds, etc . which may bl ock ventil ation.
10. Th is monitor uses publi c airwaves to transmit si gnals. The Parent U nit
may pick up sig nals or inte rferen ce from othe r monitors i n your area .
Your monitor may e ven be picked u p by other hou sehold s. To protect
your priva cy, make sure both units ar e turned OFF when not in use . If you
experien ce interf erence, c hange the c hannel o n both units .
11. Th is produc t is NOT a toy. DO NOT all ow childre n to play with it.
12. T his produ ct contai ns small pa rts. Ad ult assem bly requir ed. Exerc ise
care when unpacking and assembling the product and keep small parts
away from chil dren.
13. Wh en using th e monitor, the r oom tempe rature sho uld be bet ween
10°C and 4 0°C.
BATTERY WARNING
14. Da nger of exp losion if ba tteries a re incorre ctly repla ced. The P arent
Unit batte ry is a repl aceable L i-Ion ba ttery. Onl y use the Ang elcare
recommended replacement battery. Insert batteries with correct polarity.
DO NOT shor t-circuit su pply termi nals. O NLY use the recom mended
batterie s or equiva lent (volts an d size) and the cor rect ada pter. Remove
battery f rom Parent Unit when p roduct is s tored for lo ng period s of time
or when bat teries are ex hausted . Dispos e exhauste d batterie s properly.
WARNING
Adult assembly required.
Keep small parts away from children when
assembling.
We, at Angelcare®, stand behind all of our
products.
If you are not completely satisfied or have any
questions,
United States and Canada: Please contact us at:
angelcare@cdecinc.ca
Other countries: Please contact your local
distributor.
Keep all bat teries away f rom childr en.
15. IMPORTANT SAFETY INSTRUCTIONS
15.1 H eed all warnings – Al l warnings on the prod uct and in the operat ing
instruc tions sho uld be adh ered to.
15.2 Follow all instru ctions – Al l operati ng and use in structi ons shoul d
be followed.
15.3 Water and moisture - D O NOT use this a pparatus n ear water. For
example, n ear a bath tu b, wash bowl , kitchen sin k, laun dry tub, in a w et
environm ent or near a s wimming p ool and the l ike. Care s hould be t aken
so that obje cts DO NOT fall ont o units and that liqu ids are not spilled in to
either un it or Senso r Pad throug h its open ings.
15.4 Cleaning - Disco nnect al l units befo re cleani ng. DO NOT im merse in
water any par t of the moni tor. Clean onl y with dry cl oth.
15.5 Ventilation - DO NOT blo ck any ventilatio n openings. A llow for proper
ventilatio n when units are in us e. DO NOT cover the Came ra or the Parent
Unit with any o bject su ch as a blanke t. DO NOT pla ce it in a drawer
or in any loc ation whic h would muf fle the sou nd or inter fere with th e
normal fl ow of air.
15.6 Heat sources - DO NOT in stall near any h eat sources such a s radiators,
heat regis ters, stove s, TVs or oth er appara tus (inclu ding amp lifiers) tha t
produce h eat. Heat c an damag e the case or e lectri cal part s.
15.7 Power cord protectio n - Protect the S ensor Pa d cord and
Adapter’s p ower cord fro m being wal ked on or pinc hed by furn iture
or other ite ms – Power supp ly cords sh ould be route d so that they
are not likel y to be walked on o r pinche d by items upon o r against
them, payi ng parti cular atte ntion to cord s and plugs , convenie nce
receptac le, and the p oint wher e they exit from t he produc t.
The socket o utlet shall be inst alled near the eq uipment and shal l be easily
accessib le. Make su re to plug the a dapter to the s ocket outle t nearest
to the equip ment and that is easil y accessible. To disconn ect from mains,
unplug the adapter.
15.8 Accessories - Only use attachments/accessories specified by the
manufac turer. DO NOT pl ace this pro duct on an u nstable c art, st and,
tripod, b racket or ta ble. The p roduct may f all, cau sing seri ous injur y to
a child or ad ult and ser ious dam age to the prod uct. Use O NLY with a
cart, stand, tripod, bracket or table recommended by the manufacturer
or sold with th e produc t. Any moun ting of the pro duct sho uld follow t he
manufacturer’s instructions.
15.9 Unplug this app liance dur ing lightn ing storms o r when not u sed for
long peri ods of time .
15.10 Servicing - DO N OT attempt to se rvice this p roduct yo urself as
opening o r removing c overs (except batte ry door) may ex pose you to
dangerous voltage or other hazards.
15.11 Replacement pa rts - Whe n replacem ent par ts are requ ired, be su re
the replacement parts specified by the manufacturer have the same
charac teristic as t he origin al part. U nauthor ized substi tution may res ult
in fire, el ectric sh ock or othe r hazards .
15.12 Usage - This baby mo nitor is intende d as an aid. It is NOT a su bstitute
for respon sible and pro per adult supe rvision an d should not be us ed as such.
Use this ap pliance O NLY for its intend ed use as described i n this manu al.
15.13 Power Sources - Ope rate this prod uct only f rom the typ e of power
source ind icated on th e type pla te of the adapto r. If you are uns ure of
the type of p ower suppl y to your home , consult you r dealer o r local
power company.
15.14 Overloading - DO N OT overload wal l outlets , extensio n cords or
integral co nvenienc e receptac les as this c an result in a r isk of fire or
electric shock.
15.15 Objec t and Liqu id Entry - NE VER push objects of a ny kind into th is
product t hrough casing sl ots as they may touch da ngerous voltag e points
or short o ut parts that co uld result in a risk o f fire or electr ic shock. NEV ER
spill liqu id of any kind o n the produ ct.
2
15.16 Antenna - The anten na used for t his transm itter mus t be insta lled
to provide a se paration d istance of a t least 20 cm f rom all per sons and
must not be c ollocated or op erating in conjun ction with any othe r antenna
or tr ans mit ter.
15.17 P ower Lines - A n outside a ntenna sys tem shoul d NOT be loca ted
in the vicin ity of overhe ad power lin es or other e lectric l ight or powe r
circuit, o r where it ca n fall into suc h power line s or circuit s as contac t
with them may b e fatal.
15.18 Vibration Sourc e - When the mo nitor is in use , DO NOT use
a bedside c ot, cot mobi le or other cot a ccessor ies that may pr oduce
vibratio ns. Other s ources of vi brations m ay include f ans, was hing
machine s, loud m usic, etc . These sou rces of vibra tion may inte rfere
with the per forman ce of your Ang elcare® monitor an d the alarm w ill not
sound if it co ntinues to de tect any move ment other t han your ba by’s.
Be sure all vi bration so urces are e liminate d before usi ng the monito r.
You may experie nce false al arms for seve ral reaso ns. The mo st
common re ason is the C amera ha s not been tu rned OFF af te r
you have removed y our baby fro m the cot. Ano ther reaso n is the
Sensor Pa d has not be en placed u nder the ma ttress pro perly.
Be sure the S ensor Pad is on a fl at, firm surfa ce with the printed s ide facing
up. The sen sitivity l evel may also ne ed to be adju sted. Ref er to Step 5.1.
Always be sure to i mmediately chec k on baby whenever an al arm sounds.
15.19 Sensor Pad - Your Sens or Pad can be use d in any cot that is stati onary.
If the cot has a s pring or slat ba se, place a hard b oard between th e cot base
and the Sen sor Pad me asuring at l east 33 x 33 c m and 6 mm thic k. Only
use your Angelcare® monitor in a s tationar y sleep ing environ ment suc h
as a cot where th e Sensor Pad can res t on a complet ely flat, f irm surfa ce.
The Senso r Pad is made of plast ic and does not perm it the air to circulate .
Therefor e, milde w build up c ould deve lop und erneat h the matt ress in th e Sensor
Pad area. We su ggest rotatin g the mattress re gularly to prevent a ny mildew.
16. IMPORTANT SAFETY INSTRUCTIONS
RELATED TO USE O F BATTERIES
16.1 U se ONLY the type an d size of batteries s pecified in t he owner’s man ual.
There is a ris k of explosion if bat teries are replac ed with an incorrec t type.
16.2 Charge the bat tery for 9 ho urs prior to f irst use . Be sure to have th e
monitor in th e OFF position d uring this p eriod. O NLY use the adap ters
included with your monitor.
16.3 DO NOT use these ada pters with a ny other equ ipments .
16.4 When un plugging the a dapter from the C amera, be sure i t is switched
to the OFF positio n. If it isn’ t, the unit w ill revert to ba ttery mo de if
batteries are installed.
16.5 DO NOT dispose bat teries in fire. Th ey may explode. Che ck with local
regulati ons for pos sible spe cial dispo sal instr uctions .
16.6 Exercise care in ha ndling ba tteries i n order not to s hort out th e
batterie s with condu cting mate rials suc h as rings , bracele ts and keys.
Overcharging, short circuiting, reverse charging, mutilation, or incineration
of batteri es must be avoi ded to preven t one or more of t he followi ng
occurren ces: release of t oxic materials , release of hydrog en and/or oxygen ,
gas and ris e in surfa ce tempera ture.
16.7 DO NOT attempt to recha rge batteries p rovided with or iden tified for
use with this p roduct th at are not inte nded to be ch arged. T he batter ies
may leak cor rosive elec trolyte or e xplode.
16.8 DO NOT attempt to reju venate the batte ries provided w ith or identifi ed
for use with th is produc t by heating th em. Sud den relea se of batter y
electro lyte may occu r, causing bu rns or irri tation to eyes o r skin.
16.9 If and when neces sary, the batteries m ust be replaced with id entical
new ones or e quivale nt (volts and size). If a b attery to b e replace d is
connec ted with other batter ies in series, re place the other bat teries at the
same time a s well. DO NOT m ix old and ne w batterie s.
16.10 Reverse polarit y installation o f the batteries in t he end product m ust
be avoided . Reverse ins ertion of b atterie s can caus e charging , and that
may result in l eakage or e xplosion .
16.11 Remove batteries f rom both unit s if you store th e produc t over 30
days because the batteries could leak and damage the product.
16.12 Discard ‘dead’ b atterie s as soon as po ssible si nce ‘dead ’ batterie s
are more like ly to leak in a p roduct. I f a batter y has leake d or vented, it
should be r eplaced i mmediate ly using pr otective glove s.
16.13 DO NOT store this produ ct, or the batte ries provided wi th or identifie d
for use with th is produc t, in high -tempera ture areas .
E
N
3
SETUP REQUIREMENTS
INCLUDED:
Model AC215
Video, Movement
& Sound Monitor
Parent UnitCameraTabletop stand with removable
AC adapter
(for Parent Unit)
Wired movement Sensor Pad
* Always place Angelcare logo side up *
YOU MUST PREPARE:
One hardboard (not included)
Thickness: 6 mm
Minimum dimensions:
33 cm x 33 cm
Maximum dimensions:
equal to the mattress size
Hardboard
wall mount metal ball
(for Camera)
Lithium ion battery pack
(for Parent Unit)
(Screwdriver required
for wall mounting)
6 Pre-threaded cord covers with
AC adapter
(for Camera)
Split USB cable
WHAT YOU WILL NEED (NOT INCLUDED):
IMPORTANT
The hardboard must be larger than
the Sensor Pad surface area
4
Miniature Philips
Screwdriver
STEP 1 - CHARGING THE PARENT UNIT (9 HOURS)
1) Unlock the battery
Battery compartment lock
1
2
3
PARENT UNIT:
compartment on the backside
and remove the cover. Insert
the provided rechargeable
battery into the compartment.
Contacts of the battery
and the contacts in the
compartment must be aligned.
2) Connect the adapter to the
Parent Unit and into an
electrical outlet.
3) Charge the unit for
9 continuous
hours (prior to first use).
NOTE:
To optimize your battery performance
please refer to Battery Guidelines in the
Troubleshooting section.
E
N
VOX Indicator
Power ON/OFF
Indicator
3.5” LCD Screen
UP/DOWN Button/Volume Control
Front Side
Right Side
Sound & TIC Light Indicator
Zoom button
Zzz button
(Video ON/OFF)
MENU/SELECT
Button
Brightness
(+ or -)
Power ON/OFF
Adapter
Outlet
Speaker
(not shown)
Stand
Battery
door
5
WARNING
STRANGULATION HAZARD.
Children have STRANGLED in cords:
• Keep adapter cords out of the reach of children (more
than 1 meter away).
• Because of the serious strangulation risk to infants and
toddlers, parents and caregivers should never place
the Camera within 1 meter of a cot.
• NEVER use Sensor Pad without the cord covers. Check
cord covers before each use to ensure it is securely
placed under the leg of the cot. Discontinue use of
Sensor Pad if any cord covers are damaged or broken.
• NEVER use extension cords with adapters. ONLY use
the adapters provided. This product is not a toy. Never
allow children to play with it.
STEP 2 - POSITIONING THE MOVEMENT SENSOR PAD
2.1 - SELECT A LOCATION FOR THE CAMERA
IMPORTANT
Place the cot near a supporting wall and far from air currents. Install the Camera on a
flat, stable surface facing the cot at a distance of at least 1 metre. Make sure to plug the
adapter to the socket outlet nearest to the equipment and that is easily accessible.
Place the
Camera at least
1 metre from the
cot
1) Insert jack 1 into the Sensor Pad and twist it clockwise to lock it.
6543 21
6
2.2 - SELECT THE COT LEG TO SECURE THE CORD COVERS
RECOMMENDED
E
N
6
5
4
3
Figure 1Figure 2
2
OR
2
1
1
6
5
4
3
Use the cot leg by the wall closest to the Camera (Figure 1). In cases where the Camera is
across the room, use the leg closest to the Camera to position the covered wire (Figure 2).
It is always preferable that the covered cord run along a wall.
2.3 - INSTALL THE SENSOR PAD ON THE MATTRESS SUPPORT
IMPORTANT
If your cot does not have a solid, stable surface for the Sensor
Pad, you will need to place a support under it, to ensure correct
operation of the system.
This hardboard support should be at least 6 mm thick and should
have minimum dimensions of 33 cm x 33 cm. This support board
must be larger than the Sensor Pad surface area.
The Sensor Pad functions with any size and type of mattress except memory-foam
mattresses, hollow frame mattresses and water beds. The hardboard maintains a
constant pressure on the Sensor Pad, enabling it to detect the baby’s movements
even when the baby is at the edges of the cot.
2
Sensor Pad
3
5
6
4
3
2
1
1) Remove the mattress
2) Place the Sensor Pad –
3) Run the connection pin,
4) Bring the first 4 cord
4
5
5
5) Remove any cord slack
Hardboard
from the cot.
Angelcare logo side up –
on top of the hardboard.
warning label and the
first 5 cord covers down
along the backside of
the cot leg, between the
mattress support and the
inside edge of the cot.
covers down the floor,
and keep the 5th cord
cover vertically, along
the backside of the
cot leg, between the
mattress and the inside
edge of the cot.
to make sure no parts
of the cord are loose.
7
6
8 cm
6
4132
4
3
2
1
WARNING
6) Place the 6th cord
cover approximately
8 cm from the edge of
the mattress support.
7
89
STRANGULATION HAZARD
• Remove all slack from Sensor Pad Cord.
• When lowering the mattress support
as your child grows, slide the vertical
Cord Cover downward so it remains
approximately in the center between
the mattress support and the floor. Slide
the Sensor Pad Cord through the Floor
Cover to eliminate any additional slack.
CLIC!
7) Snap together the
remaining cord covers that
will run along the floor.
8) Remove any cord
slack to make sure no
parts of the cord are
loose.
9) Peel off the double-
sided tape on the 4th
cord cover and place
it securely under the
cot leg.
• The Sensor Pad is not designed
for use with adults, children or infants
older than 24 months.
• Discontinue used of the Sensor Pad
when child is older than 24 months.
Remove Sensor Pad from cot and store
for future use.
• BEFORE FIRST TIME USE: To test
that the unit is ready for use, refer to
instruction manual on how to test that
the installation has been done correctly.
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.