Andersen CB00011072401 Users Manual

VeriLock® Security Sensor Application
VeriLock® Security Sensor Application
for Andersen® A-Series Frenchwood Hinged Inswing & Outswing, 400 Series Frenchwood® Hinged Inswing & Outswing and Hinged Inswing & Outswing Entry Doors
for Andersen® A-Series Frenchwood Hinged Inswing & Outswing, 400 Series Frenchwood® Hinged Inswing & Outswing and Hinged Inswing & Outswing Entry Doors
Thank you for choosing Andersen. / Gracias por elegir Andersen.
For questions call 1-888-888-7020. For more information and/or guides visit andersenwindows.com.
Please leave this guide with building owner.
Si tiene alguna pregunta llame al 1-888-888-7020. Para obtener más información y/o guías, visite andersenwindows.com.
Deje esta guía con el dueño de la construcción.
▶ Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.
Lea completamente la guía antes de comenzar la instalación. Lea y respete todas las advertencias y precauciones durante la instalación de la unidad.
▶ Check with your local building code ofcial to identify and conrm compliance with local building code requirements.
Consulte los códigos locales de construcción para identicar y conrmar que se cumplan los requisitos del código de construcción.
Parts Included / Partes Incluidas
(1) Instruction Guide / Instruction Guide (4) VeriLock Face Plate / VeriLock Face Plate (1) VeriLock Sensor / VeriLock Sensor (1) Actuator / Actuator
(2) CR-2032 Battery / CR-2032 Battery (1) Cylinder Magnet / Cylinder Magnet (1) Block Magnet / Block Magnet
(4) #8 x 1-3/4" Bolt (2 white, 2 stone) (Tribeca® Hardware Only) / #8 x 1-3/4" Bolt (2 white, 2 stone)
(Tribeca® Hardware Only)
VeriLock® Face Plate
VeriLock® Face Plate
CR-2032 Battery
CR-2032 Battery
VeriLock® Sensor
VeriLock® Sensor
Actuator
Actuator
Cylinder Magnet
Cylinder Magnet
Cylinder Magnet Cap
Cylinder Magnet Cap
Block Magnet
Block Magnet
Block Magnet Cap
Block Magnet Cap
Additional Parts Required for Entry Doors Only (Ordered Seperately)
Additional Parts Required for Entry Doors Only (Ordered Seperately)
(1) Extended Lock Actuator /
Extended Accionador del cerrojo
Tools Needed / Herramientas Necesarias
∙ Safety Glasses / Lentes de seguridad ∙ Phillips Screwdriver / Destornillador Phillips ∙ 1/8" Hex Key / Hex Key de 1/8" ∙ Drill/Driver / Taladro/destornillador ∙ 5/16" Drill Bit / Broca para taladro de 5/16" ∙ Tape Measure / Tape Measure ∙ Drop Cloth / Drop Cloth
“Andersen” and all other marks where denoted are trademarks of Andersen Corporation and its subsidiary. © 2016 Andersen Corporation. All rights reserved.
“Andersen” y todas las demás marcas que aparezcan son marcas registradas de Andersen Corporation y su subsidiaria © 2016 Andersen Corporation. Todos los derechos reservados.
Depending on individual installation requirements, some parts may not be used.
Depending on individual installation requirements, some parts may not be used.
#8 x 1-3/4" Bolt
(Tribeca Hardware Only)
#8 x 1-3/4" Bolt
(Tribeca Hardware Only)
Screw Standoff
Screw Standoff
4-1/4" Spindle
4-1/4" Spindle
9139831 BA -01 Revised 02/21/16
Use caution when working at elevated heights and around unit openings. Follow manufacturers’ instructions for ladders and/or scaffolding. Failure to do so may result in injury or death.
Sea cauteloso al trabajar en lugares elevados y cerca de las aberturas de la unidad. Siga las instrucciones del fabricante para el uso de escaleras y/o andamios. Si no lo hiciera, podrían producirse lesiones o la muerte.
Follow manufacturers’ instructions for hand or power tools. Always wear safety glasses. Failure to do so may result in injury and/or product damage.
Siga las instrucciones del fabricante para el uso de herramientas eléctricas o manuales. Utilice siempre gafas de seguridad. Si no lo hiciera, podrían producirse lesiones y/o daños al producto.
Batteries carry the risk of re, explosion and burns. Do not recharge, disassemble, heat above 212 degrees F (100 degrees C) or incinerate. Dispose of used batteries promptly and properly. Keep away from children.
Les piles représentent un risque d’incendie, d’explosion et de brûlures. Ne pas recharger, démonter, chauffer à une température excédant 100degrés C (212degrésF) ou incinérer. Éliminer les piles rapidement et de manière appropriée. Garder à l’écart des enfants.
Batteries are small parts and, if swallowed, could pose a choking hazard to young children.
Las baterías son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.
Magnetic eld can be harmful to implanted medical device wearers. Keep magnets away from devices.
Magnetic eld can be harmful to implanted medical device wearers. Keep magnets away from devices.
Magnets are small parts and, if swallowed, could pose a choking hazard to young children.
Los imanes son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.
9139831
2
1
Interior
Exterior Handle
Manija exterior
2
Interior
Interior Active Escutcheon
Escudete con apertura interior
Set Screw
Tornillo de jación
1/8" Hex Key
Hex Key de 1/8"
Bushing
Casquillo
Spindle
Husillo
Bushing
Casquillo
Interior Handle
Manija interior
Lay a drop cloth down to prevent losing parts. Unlock and open active door panel. Loosen set
screw on exterior handle using 1/8" hex key. Remove handles and set aside for reuse.
Lay a drop cloth down to prevent losing parts. Unlock and open active door panel. Loosen set
screw on exterior handle using 1/8" hex key. Remove handles and set aside for reuse.
3
Interior
Dummy Cylinder
Falso cilindro
Support exterior components when loosening cylinder mounting bolts.
Support exterior components when loosening cylinder mounting bolts.
Escutcheon Bolt
Perno de escudete
Remove escutcheon bolts and interior active escutcheon. Set aside for reuse.
Remove escutcheon bolts and interior active escutcheon. Set aside for reuse.
Entry Doors Only /Entry Doors Only
Exterior Active Escutcheon
Escudete con apertura exterior
Lock Mechanism
Mecanismo del cerrojo
Gasket
Junta
Cylinder Mounting Bolts
(do not fully remove)
Pernos de montaje del cilindro
(do not fully remove)
Lock Actuator
Lock Actuator
Limiting Plate
Placa limitadora
Cylinder Mounting Bolts
Pernos de montaje del cilindro
Extended Lock Actuator
Extended Lock Actuator
Existing Lock Actuator
Existing Lock Actuator
Loosen cylinder mounting bolts until exterior components can be removed. Set exterior components aside for reuse.
Loosen cylinder mounting bolts until exterior components can be removed. Set exterior components aside for reuse.
9139831
For Entry Doors only, remove cylinder mounting bolts, limiting plate and lock actuator. Replace existing lock actuator with extended lock actuator. Reapply parts as shown, do not fully tighten bolts.
For Entry Doors only, remove cylinder mounting bolts, limiting plate and lock actuator. Replace existing lock actuator with extended lock actuator and reapply parts as shown, do not fully tighten bolts.
3
4
Interior
Tribeca® Hardware Only
Tribeca® Hardware Only
Mounting Stud
Mounting Stud
Screw Standoff
Screw Standoff
Exterior Active Escutcheon
Escudete con apertura exterior
Verify gasket is seated properly.
Verify gasket is seated properly.
Mounting Stud
Mounting Stud
Screw Standoff
Screw Standoff
Apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.
Apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.
Removable Mounting Stud
Removable Mounting Stud
Exterior Active Escutcheon
Escudete con apertura exterior
Removable Mounting Stud
Removable Mounting Stud
Screw Standoff
Screw Standoff
Verify gasket is seated properly.
Verify gasket is seated properly.
Screw Standoff
Screw Standoff
For Tribeca hardware only, apply removable mounting studs as shown, then apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.
For Tribeca hardware only, apply removable mounting studs as shown, then apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.
5
Interior
Dummy Cylinder
Falso cilindro
Cylinder Mounting Bolts
Pernos de montaje del cilindro
Exterior Active Escutcheon
Escudete con apertura exterior
Re-apply exterior components and tighten cylinder mounting bolts.
Re-apply exterior components and tighten cylinder mounting bolts.
6
Interior
VeriLock Face Plate
VeriLock Face Plate
VeriLock Sensor
VeriLock Sensor
CR-2032 Batteries
CR-2032 Batteries
VeriLock® Assembly
VeriLock® Assembly
(back views)
(back views)
Indicator Light
Indicator Light
(front view)
(front view)
Select preferred color VeriLock face plate. Press sensor into back side of face plate and install batteries with (+) facing out as shown. Indicator light will illuminate for one (1) second when batteries are installed correctly.
Select preferred color VeriLock face plate. Press sensor into back side of face plate and install batteries with (+) facing out as shown. Indicator light will illuminate for one second when batteries are installed correctly.
9139831
4
7
Interior
VeriLock assembly can be rotated for use on either left handed (LH) or right handed (RH) panels.
VeriLock assembly can be rotated for use on either left handed (LH) or right handed (RH) panels.
Top Hole
Top Hole
VeriLock® Assembly
(tab must point toward latch side of panel)
VeriLock® Assmbly
Tab
Tab
Latch
Latch
(tab must point toward latch side of panel)
Actuator
(in top hole only)
Actuator
(in top hole only)
Alignment Tabs
(will fit in only one orientation)
Alignment Tabs
(will fit in only one orientation)
(Verify arrows align on the tab side as shown)
(Verify arrows are aligned as shown on the tab side)
VeriLock® Assembly
(back view)
VeriLock® Assmbly
(back view)
Tab side as viewed from back.
Tab side as viewed from back.
Rotate VeriLock assembly to the correct orientation (tab side must point toward the latch side of panel). Insert actuator into top hole of VeriLock assembly from back side as shown.
Rotate VeriLock assembly to the correct orientation. (tab side must point toward the latch side of panel).
8
Interior
Sensor contains an anti-tamper switch. Do not apply sensor over wet nish or rough/dirty surface. Improper switch
function may result.
Sensor contains an anti-tamper switch.
Lock Actuator
Accionador del cerrojo
Do not apply sensor over wet nish or rough/dirty surface. Improper switch function may result.
VeriLock Assembly
VeriLock Assembly
Actuator
Accionador
VeriLock Sensor
(anti-tamper switch)
VeriLock Sensor
(anti-tamper switch)
Indicator Light
Indicator Light
Verify panel surface is clean and dry. Position VeriLock assembly on the panel over the lock actuator as shown. The indicator will illuminate for one (1)
second when the sensor is applied to the panel as the anti-tamper switch is depressed.
Verify panel surface is clean and dry. Position assembly on the panel over the lock actuator as shown. The indicator will illuminate for one (1) second
when the sensor is applied to the panel as the anti-tamper switch is depressed.
9139831
5
9
Interior
Interior Active Escutcheon
Escudete con apertura interior
Escutcheon Bolt
Perno de escudete
Position interior escutcheon on panel as shown and fasten bolts (do not fully tighten until handles have been installed).
Position interior escutcheon on panel as shown and fasten bolts (do not fully tighten until handles have been installed).
Tribeca® Hardware Only
Tribeca® Hardware Only
#8 x 1-3/4" Bolt
#8 x 1-3/4" Bolt
Replace existing bolts with #8 x 1-3/4" bolts.
Replace existing bolts with #8 x 1-3/4" bolts.
10
Interior
4-1/4" Spindle
4-1/4" Spindle
Existing Spindle
Existing Spindle
Spindle
Husillo
Hex Key
Hex Key
Spindle (V-Slot)
Husillo (ranura en forma de V)
Line up v-slot with set screw
Alinee la ranura en forma de V con el tornillo de fijación
Bottom View/
Vista inferior
Set Screw
Tornillo de jación
Loosen set screw on handle and remove spindle. Replace existing spindle with 4-1/4"spindle and tighten set screw. Set screw must enter v-slot in spindle when securing the handle.
Loosen set screw on handle and remove spindle. Replace existing spindle with extended spindle and tighten set screw. Set screw must enter v-slot in spindle when securing the handle.
11
Interior
Handles must point toward the glass with set screw on the bottom.
Las manijas deben apuntar hacia el vidrio con el tornillo de jación en la parte inferior.
Exterior Handle
Manija exterior
Set Screw
Tornillo de jación
Bushing
Casquillo
Interior Handle
Manija interior
Hex Key
Hex Key
Bushing
Casquillo
Spindle
Husillo
Slide handles and bushings together tightly. Insert set screw in exterior handle and tighten using hex key. Finish tightening escutcheon bolts.
Slide handles and bushings together tightly. Insert set screw in exterior handle and tighten using hex key. Finish tightening escutcheon bolts.
9139831
6
Magnets are small parts and, if swallowed, could pose a choking hazard to young children.
Los imanes son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.
Magnet Application/ Magnet Application
12
As viewed from the exterior.
As viewed from the exterior.
As viewed from the exterior.
As viewed from the exterior.
Selection of the correct door conguration is critial for magnet application. Wrong conguration selection will result in improper magent application and product damage.
Selection of the correct door conguration is critial for magnet application. Wrong conguration selection will result in improper magent application and product damage.
For DOUBLE operating, OUTSWING doors, go to Step 12a.
For DOUBLE operating, OUTSWING doors, go to Step 12a.
Or
Or
For DOUBLE operating, INSWING doors, go to Step 12b.
For DOUBLE operating, INSWING doors, go to Step 12b.
Or
Or
As viewed from the exterior.
As viewed from the exterior.
For SINGLE operating, OUTSWING doors, go to Step 12c.
Or
Or
▶ For SINGLE operating, OUTSWING doors, go to Step 12c.
Stationary Panel
Stationary Panel
As viewed from the exterior.
As viewed from the exterior.
Determine door your conguration and proceed to appropriate section for magnet installation.
Determine door your conguration and proceed to appropriate section for magnet installation.
Stationary Panels
Stationary Panels
▶ For SINGLE operating, INSWING doors,
go to Step 12d.
For SINGLE operating, INSWING doors, go to Step 12d.
9139831
7
Order Designation Description
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
Door Rough
Opening
Stationary
Panel
Active
Panel
Stationary
Panel
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood
®
Hinged Inswing Patio Door
FWH
Frenchwood
®
Hinged Inswing Patio Door
12a
For DOUBLE Operating, OUTSWING Doors Only
For DOUBLE Operating, OUTSWING Doors Only
Active Panel
Active Panel
Interior View
Interior View
Passive Panel
Passive Panel
As viewed from the exterior.
As viewed from the exterior.
Cylinder Magnet Cap
Cylinder Magnet Cap
Cylinder Magnet
Cylinder Magnet
Press cylinder magnet rmly into preferred color cylinder magnet cap.
Press cylinder magnet rmly into preferred color cylinder magnet cap.
Close doors and lightly mark magnet location across from bottom arrow on VeriLock face plate, as shown.
Close doors and lightly mark magnet location across from bottom arrow on VeriLock face plate, as shown.
Astragal
Astragal
Interior View
Interior View
Astragal
Astragal
5/16" Drill Bit
5/16" Drill Bit
Open active panel and drill 5/16" hole at marked location in center of astragal side, as shown.
Open active door and drill 5/16" hole at marked location in center of side surface, as shown.
Center of astragal side.
Center of astragal side.
Insert cylinder magnet with cap into drilled hole.
Insert cylinder magnet with cap into drilled hole.
Install magnet on your DOUBLE operating, OUTSWING, door as shown.
Install magnet on your DOUBLE operating, OUTSWING, door as shown.
9139831
8
12b
For DOUBLE Operating, INSWING Doors Only
For DOUBLE Operating, INSWING Doors Only
As viewed from the exterior.
As viewed from the exterior.
Block Magnet Cap
Block Magnet Cap
Active Panel
Active Panel
Block Magnet
Block Magnet
Passive Panel
Passive Panel
Remove adhesive liner from one side of block magnet and press rmly into preferred color block magnet cap.
Remove adhesive liner from one side of block magnet and press rmly into preferred color block magnet cap.
Edge of Passive Panel
Edge of Passive Panel
Bottom Arrow
Bottom Arrow
Remove second adhesive liner from block magnet with cap.
Remove second adhesive liner from block magnet with cap.
Position block magnet with cap to front surface of passive panel, ush to edge, and centered across from bottom arrow on VeriLock face plate.
Position block magnet with cap to front surface of passive panel, ush to edge, and centered across from bottom arrow on VeriLock face plate.
Interior View
Interior View
Install magnet on your DOUBLE operating, INSWING, door as shown.
Install magnet on your DOUBLE operating, INSWING, door as shown.
9139831
9
12c
Order Designation Description
Left
6068 A S R
Door Rough
Opening
Active Panel
Stationary
Panel
Right
Hinged
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood
®
Hinged Inswing Patio Door
FWH
Frenchwood
®
Hinged Inswing Patio Door
For SINGLE Operating, OUTSWING Doors Only
For SINGLE Operating, OUTSWING Doors Only
Interior View
Interior View
Cylinder
As viewed from the exterior.
As viewed from the exterior.
Magnet Cap
Cylinder Magnet Cap
Bottom Arrow
Bottom Arrow
Cylinder Magnet
Cylinder Magnet
Press cylinder magnet rmly into preferred color cylinder magnet cap.
Press cylinder magnet rmly into preferred color cylinder magnet cap.
Panel Stop
Panel Stop
Lightly mark magnet location on panel stop across from bottom arrow on VeriLock face plate, as shown.
Lightly mark magnet location on panel stop across from bottom arrow on VeriLock face plate, as shown.
Interior View
Interior View
5/16" Drill Bit
5/16" Drill Bit
1/4"
Open door and drill 5/16" hole, 1" deep, 1/4" from panel stop edge.
Open door and drill 5/16" hole, 1" deep, 1/4" from panel stop edge.
Insert cylinder magnet with cap into drilled hole.
Insert cylinder magnet with cap into drilled hole.
Install magnet on your SINGLE operating, OUTSWING, door as shown.
Install magnet on your SINGLE operating, OUTSWING, door as shown.
9139831
10
12d
For SINGLE Operating, INSWING Doors Only
For SINGLE Operating, INSWING Doors Only
As viewed from the exterior.
As viewed from the exterior.
Cylinder Magnet Cap
Cylinder Magnet Cap
Interior View
Interior View
Interior View
Interior View
Cylinder Magnet
Cylinder Magnet
Press cylinder magnet rmly into preferred color cylinder magnet cap.
Press cylinder magnet rmly into preferred color cylinder magnet cap.
5/16" Drill Bit
5/16" Drill Bit
Strike Plate
Strike Plate
Jamb
Jamb
Open door and mark magnet location on jamb (even with bottom strike plate screw and centered in the area between the strike plate and jamb edge).
Open door and mark magnet location on jamb (even with bottom strike plate screw and centered in the area between the strike plate and jamb edge).
Edge of jamb.
Edge of jamb.
Drill 5/16" hole, 1" deep, at marked location.
Drill 5/16" hole, 1" deep, at marked location.
Install magnet on your SINGLE operating, INSWING, door as shown.
Install magnet on your SINGLE operating, INSWING, door as shown.
9139831
Insert cylinder magnet with cap into drilled hole.
Insert cylinder magnet with cap into drilled hole.
11
13
Interior
Verify VeriLock Sensor Function / Verify VeriLock Sensor Function
Thumb Turn Latch
Thumb Turn Latch
Indicator Light
Indicator Light
Unlocked
Unlocked
Locked
Locked
1. Close door without locking. Indicator light will illuminate for one (1) second.
2. Engage all upper, middle and lower hooks and lock door with dead bolt. Indicator light will illuminate for one (1) second. Verify door is locked.
3. Unlock door with dead bolt. Indicator light will illuminate for one (1) second.
4. Open door. Indicator light will illuminate for one (1) second.
1. Close door without locking. Indicator light will illuminate for one (1) second.
2. Engage all upper, middle and lower hooks and lock door with dead bolt. Indicator light will illuminate for one (1) second. Verify door is locked.
3. Unlock door with dead bolt. Indicator light will illuminate for one (1) second.
4. Open door. Indicator light will illuminate for one (1) second.
Verify VeriLock® sensor function. If indicator light does not respond as described, verify sensor application and magnet placement.
Verify VeriLock® sensor function. If indicator light does not respond as described, verify sensor application and magnet placement.
▶ Procedure is complete.
Procedure is complete.
Refer to monitoring system of your choice for sensor enrollment. /
Refer to monitoring system of your choice for sensor enrollment.
For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide.
For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide.
9139831
12
Regulatory Statements / Regulatory Statements
Federal Communications Commission (FCC) Part 15 Statement
This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation.
Industry Canada (IC) RSS Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de I'appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by Andersen may void the user's authority to operate the equipment.
Federal Communications Commission (FCC) Part 15 Statement
This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation.
Industry Canada (IC) RSS Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de I'appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by Andersen may void the user's authority to operate the equipment.
9139831
13
Loading...