Analog Devices B42 3 4 Datasheet

Isolated AC Sine Wave Input
FEATURES
AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals.
Accepts inputs of between 20 mV to 550 V rms to give an rms output reading.
Module provides simultaneous precision voltage and current outputs.
Module circuitry can withstand 130v rms at the input screw­terminals.
All 3B42, 3B43, & 3B44 series modules are mix-and-match and Hot Swappable.
APPLICATIONS
Industrial signal conditioning Industrial signal isolation Industrial signal filtering
PRODUCT OVERVIEW
The 3B Series of Signal Conditioning I/o Subsystems provide a low-cost, versatile method of transferring analog transducer signals to a data acquisition, monitoring or control system without the inherent noise, non-linearity, drift and extraneous voltages. The modules are designed to directly accept analog signals from Thermocouples, RTD’s, AC and DC Strain Gages, Torque Transducers, Frequency Transducers, LVDTs, millivolt or process current signals. The modules amplify, isolate, linearize and convert the transducer output signals to standardized analog inputs for high-level analog I/O subsystems. The 3B Series Subsystem consists of a 10” relay rack with universal mounting backplane and a family of plug-in (up to 16 per rack) input and output signal conditioning modules.
Eight and four channel backplanes are also available. Each backplane incorporates screw terminals for sensor inputs and current outputs and a 26-pin connector for high-level single­ended voltage outputs to the user’s equipment.
The input modules feature complete signal conditioning circuitry optimized for specific sensors or analog signals and provide two simultaneous high-level analog outputs: 0 to +10V
10V) and 4-20 mA (or 0-20 mA).
(or +
3B42 / 3B43 / 3B44
FUNCTIONAL BLOCK DIAGRAM
Figure 1. 3B42, 3B43, & 3B44 Functional Block Diagram
Output modules accept 0 to +10V (or +10V) single-ended signals and provide an isolated 4-20 mA (or 0-20 mA) process signal. All modules feature a universal pin-out and may be readily hot-swapped under full power and interchanged without disrupting field wiring.
The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applications. Some typical uses are in microcomputer-based data acquisition systems, programmable controllers, analog recorders, dedicated control systems, and any other applications where monitoring of temperature, pressure, flow and analog signals are required. Since each input module features two simultaneous outputs, the voltage output can be used to provide an input to a microprocessor-based data acquisition or control system while the current output can be used for analog transmission, operator interface, or an analog backup system.
Each input module is a single-channel signal conditioner which plugs into a socket on the backplane and accepts its signal from the input screw terminals. All input modules provide input protection, amplification and filtering of the input signal, accuracy of + modules), and feature two high-level analog outputs that are compatible with most process instrumentation. The isolated input modules also provide +
The choice of a specific 3B module depends upon the type of input signal. Input modules are available to accept millivolt, volt, process current, thermocouple, RTD, AC and DC strain gage, frequency and LVDT inputs. The voltage output of each module is available from the system I/O connector while the current output is available on the output screw terminals.
0.1%, low drift of +1 uV/ oC (low-level input
1500 V peak isolation.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.326.8703 © 2004 Analog Devices, Inc. All rights reserved.
www.analog.com
GENERAL DESCRIPTION
The 3B42, 3B43, and 3B44 are single-channel AC sine wave signal conditioning modules which use an AC averaging technique to rectify, amplify, and filter 50 Hz to 400 Hz sine­wave signals ranging from 20 mV to 550 V rms to give an rms output reading. Simultaneous precision voltage and current outputs are provided including isolation (+ to-output and power). The 3B42 and 3B43 modules withstand 220 V rms, and Model 3B44 withstands 550 V rms at its input terminals without damage, thereby shielding computer-side circuitry from field-side over-voltage conditions. Each plug-in, mix-and-match, hot-swappable module is easily field calibrated via front-panel zero and span adjustments for both voltage and current outputs.
3B Series Custom-Ranging Program – Externally-
.
1500 V peak input-
3B42 / 3B43 / 3B44
programmable versions, Models 3B42-00, 3B43-00, and 3B44­00, enable the user to configure a special input range by using the optional plug-on AC1310 ranging card, which houses user­supplied resistors to determine zero and span. To facilitate selecting resistors, a Windows program, 3B-CUSTOM, calculates resistor values based on the user-desired input/output ranges.
Signal isolation by transformer coupling uses a proprietary modulation technique for linear, stable and reliable performance. The differential input circuit on the field side is fully floating, eliminating the need for any input grounding. A demodulator on the computer side of the signal transformer recovers the original signal, which is then filtered and buffered to provide a low-noise, low-impedance output signal.
.
Figure 2
Rev. 0 | Page 2 of 8
3B42, 3B43 and 3B44 Models Available
Model Input Range Output Ranges1
3B42-00 3B42-01 3B42-02
3B42-Custom
Model Input Range Output Ranges1 3B43-00 3B43-01
3B43-Custom
Model Input Range Output Ranges 3B44-00 3B44-01 3B44-02
3B44-Custom
1
Output current range may be user programmed to 4 mA to 20 mA using jumper supplied.
2
Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
Externally Programmable2 0 V to +10 V & 0 mA to 20 mA
0 mV to +50 mV rms 0 V to +10 V & 0 mA to 20 mA
0 mV to +100 mV rms 0 V to +10 V & 0 mA to 20 mA
* *
Externally Programmable2 0 V to +10 V & 0 mA to 20 mA
0 V to +10 V rms 0 V to +10 V & 0 mA to 20 mA
* *
Externally Programmable
0 V to +150 V rms 0 V to +10 V & 0 mA to 20 mA 0 V to +250 V rms 0 V to +10 V & 0 mA to 20 mA
* *
3B42 / 3B43 / 3B44
1
2
0 V to +10 V & 0 mA to 20 mA
3B42, 3B43 and 3B44 Specifications
(typical @ +25°C and ±15 V dc, and +24 V dc Power)
Description Model 3B42 Model 3B43 Model 3B44
Input Ranges
Standard Ranges, 50 Hz to 400 Hz Refer to Model Table Refer to Model Table Refer to Model Table Custom Ranges, 50 Hz to 400 Hz 20 mV rms to 1 V rms 1 V rms to 50 V rms 50 V rms to 550 V rms
Output Ranges
Voltage (R Current (RL + 0 to 850 Ω)1
Initial @ +25°C ±0.05% Span * * Nonlinearity ±0.02% Span * *
Voltage Output Zero ±0.005% of Span/°C * * Span ±0.005% of Reading/°C * * Current Output Zero ±25 ppm of Span/°C * * Span ±25 ppm of Reading/°C * *
Zero and Span Adjustment Range4
> 2 kΩ)
L
3
0 V to +10 V * * 4 mA to 20 mA or 0 mA to 20 mA * *
Accuracy2
Stability vs. Temperature
±5% of Span * *
Rev. 0 | Page 3 of 8
Loading...
+ 5 hidden pages